OSHA has inspected Cardi Corporation 74 times in Rhode Island since 1975.
The latest one began on Oct 22, 2019 on a referral, in Cumberland.
Those inspections ended with 90 citation items: 57 serious, 5 repeat and 28 other-than-serious.
Penalties were first proposed at $117,365 and now stand at $68,154, 42% lower after settlements or reviews.
Excavations comes up most often in these citations: 13 items under 1926.651.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Cardi Corporation averages $5,478 (2 cited inspections).
Cardi Corporation also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Rhode Island · latest 90 days of OSHA records
79 employers cited
Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.
See who gets cited next Latest cited in Rhode Island
Checking a subcontractor, a client or your own company? Watch Cardi Corporation and get notified the morning OSHA posts a new citation for it.
Watch this company
Inspection history Inspection 344392642 OPENED OCT 22, 2019 Closed Referral · Partial · Safety · 300 employees at the site · Closed Feb 10, 2020
Bridge Above Leigh Road, Cumberland, RI 02864 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
Incident on Oct 19, 2019: Employee suffers multiple injuries in fall through hole
At 2:00 a.m. on October 19. 2019, an employee, a foreman, was moving the Jersey barriers on a road construction project in order to reroute traffic when he fell through a hole on a bridge. The employee fell approximately 19 feet to the ground below. The employee was hospitalized to treat multiple fractures and a punctured lung.
Citation and rule Type Proposed Current Issued Status Citation 1, item 2
Serious $13,260 $7,956 Jan 14, 2020 Final
Inspection 344335310 OPENED SEP 24, 2019 Closed Planned · No inspection · Safety · 20 employees at the site · Closed Sep 26, 2019
Rt-37 C-1, Warwick, RI 02886 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 340921485 OPENED SEP 16, 2015 Closed Referral · Partial · Safety · 400 employees at the site · Closed Apr 25, 2016
162 Broadway, Newport, RI 02840 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Other-than-serious $7,000 $3,000 Feb 2, 2016 Final
Inspection 339876088 OPENED JUL 28, 2014 Closed Planned · No inspection · Safety · 100 employees at the site · Closed Sep 11, 2014
Central Bridge Rt.114, Barrington, RI 02806 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 339633794 OPENED MAR 12, 2014 Closed Planned · No inspection · Safety · 5 employees at the site · Closed Mar 17, 2014
400 Lincoln Ave., Warwick, RI 02888 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 339859696 OPENED FEB 12, 2014 Closed Planned · No inspection · Safety · 100 employees at the site · Closed May 15, 2014
65 Shun Pike, Johnston, RI 02919 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 339014292 OPENED APR 16, 2013 Closed Planned · Complete · Safety · 189 employees at the site · Closed Apr 19, 2013
Chalkstone Ave/raymond St, Providence, RI 02908 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 339001539 OPENED APR 10, 2013 Closed Planned · Complete · Safety · 200 employees at the site · Closed May 24, 2013
Gano St. & Warren Ave., Providence, RI 02908 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
66 older inspections Inspection 339001869 OPENED APR 10, 2013 Closed Planned · Complete · Safety · 200 employees at the site · Closed May 24, 2013
North Kingstown Various Locations, North Kingstown, RI 02852 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 338231616 OPENED JAN 10, 2013 Closed Planned · No inspection · Safety · 1 employee at the site · Closed Jan 15, 2013
Station St, Coventry, RI 02816 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 338072010 OPENED DEC 31, 2012 Closed Planned · Partial · Safety · 315 employees at the site · Closed Jan 16, 2013
Evans Ave. (underpass), Tiverton, RI 02878 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 336673181 OPENED OCT 1, 2012 Closed Planned · Partial · Safety · 50 employees at the site · Closed Oct 23, 2012
Orms St, Providence, RI 02904 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 334485141 OPENED MAY 18, 2012 Closed Planned · Complete · Safety · 100 employees at the site · Closed Jul 6, 2012
Bridge# 495, Portsmouth, RI 02871 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 314919598 OPENED SEP 21, 2011 Closed Planned · Partial · Safety · 200 employees at the site · Closed Oct 24, 2011
Riverside Avenue, Portsmouth, RI 02871 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 314918897 OPENED AUG 31, 2011 Closed Referral · Partial · Safety · 199 employees at the site · Closed Jan 17, 2012
160 Valley St, East Providence, RI 02914 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 314916529 OPENED MAR 15, 2011 Closed Planned · Complete · Safety · 200 employees at the site · Closed Apr 27, 2011
Riverside Drive, Tiverton, RI 02878 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 312344310 OPENED DEC 22, 2009 Closed Planned · Complete · Safety · 150 employees at the site · Closed Dec 22, 2009
Weaver Hill Road, West Greenwich, RI 02817 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 312343734 OPENED OCT 23, 2009 Closed Referral · Partial · Safety · 100 employees at the site · Closed Feb 9, 2010
Evans Street, Tiverton, RI 02878 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $3,000 $1,000 Nov 23, 2009 Closed
Inspection 312344542 OPENED OCT 23, 2009 Closed Unprogrammed other · Partial · Safety · 100 employees at the site · Closed Feb 24, 2010
Riverside Avenue, Portsmouth, RI 02871 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 312340318 OPENED JAN 22, 2009 Closed Planned · No inspection · Safety · Closed Jan 22, 2009
Henderson Bridge, Providence, RI 02903 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 312339799 OPENED DEC 17, 2008 Closed Planned · Complete · Safety · 400 employees at the site · Closed Dec 18, 2008
Main Street/great Road Bridges, North Smithfield, RI 02824 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 310161617 OPENED JUL 11, 2008 Closed Referral · Partial · Safety · 100 employees at the site · Closed Aug 21, 2008
Rt 95 At Point St Overpass, Providence, RI 02903 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 307577148 OPENED MAR 24, 2006 Closed Referral · Partial · Safety · 100 employees at the site · Closed Mar 21, 2008
Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Other-than-serious $3,000 $1,000 Aug 21, 2006 Final
Inspection 307571786 OPENED JAN 20, 2005 Closed Referral · Partial · Health · 100 employees at the site · Closed Jul 1, 2008
Rt 114, Warren, RI 02885 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $500 $0 Apr 18, 2005 Final
Inspection 307571505 OPENED DEC 8, 2004 Closed Planned · Complete · Safety · 12 employees at the site · Closed Jan 18, 2005
Rt 195 India Street, Providence, RI 02907 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
Citation and rule Type Proposed Current Issued Status Citation 1, item 1a
Serious $1,300 $650 Dec 21, 2004 Closed Citation 1, item 1b
Serious $0 $0 Dec 21, 2004 Closed
Inspection 307571299 OPENED NOV 23, 2004 Closed Complaint · Complete · Safety · 5 employees at the site · Closed Nov 29, 2004
Public Street, Providence, RI 02907 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 307569715 OPENED JUL 22, 2004 Closed Planned · Partial · Safety · 18 employees at the site · Closed Jul 23, 2004
Rte 116, Lincoln, RI 02865 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 307569582 OPENED JUL 13, 2004 Closed Planned · Complete · Safety · 5 employees at the site · Closed Jul 14, 2004
Rte 6, Providence, RI 02903 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 304993819 OPENED SEP 9, 2003 Closed Planned · Complete · Safety · 3 employees at the site · Closed Jan 27, 2004
Keifer Park, North Kingstown, RI 02852 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $2,125 $1,275 Sep 30, 2003 Closed Citation 1, item 2
Serious $2,125 $1,275 Sep 30, 2003 Closed Citation 1, item 3
Serious $2,125 $1,275 Sep 30, 2003 Closed Citation 1, item 4
Serious $5,000 $3,000 Sep 30, 2003 Closed Citation 2, item 1
Repeat $12,500 $7,500 Sep 30, 2003 Closed
Inspection 304992134 OPENED MAY 14, 2003 Closed Complaint · Complete · Safety · 15 employees at the site · Closed Jul 29, 2003
400 Lincoln Avenue, Warwick, RI 02888 · Construction Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
Citation and rule Type Proposed Current Issued Status Citation 1, item 1a
Serious $1,062 $1,062 Jun 10, 2003 Closed Citation 1, item 1b
Serious $0 $0 Jun 10, 2003 Closed Citation 1, item 2a
Serious $2,500 $2,500 Jun 10, 2003 Closed Citation 1, item 2b
Serious $0 $0 Jun 10, 2003 Closed
Inspection 304991466 OPENED MAR 25, 2003 Closed Planned · Partial · Safety · 400 employees at the site · Closed Mar 25, 2003
Cranston Street, Cranston, RI 02920 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
No citations from this inspection.
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $2,125 $1,062 Jul 10, 2002 Closed
No citations from this inspection.
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $1,625 $812 Sep 26, 2001 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $2,000 $1,000 Aug 4, 1999 Closed Citation 2, item 1
Repeat $4,000 $2,400 Aug 4, 1999 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $4,000 $2,400 Jun 29, 1999 Closed Citation 1, item 2a
Serious $1,600 $960 Jun 29, 1999 Closed Citation 1, item 2b
Serious $0 $0 Jun 29, 1999 Closed
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
No citations from this inspection.
Citation and rule Type Proposed Current Issued Status Citation 1, item 1a
Serious $975 $488 Apr 30, 1998 Closed Citation 1, item 1b
Serious $0 $0 Apr 30, 1998 Closed Citation 1, item 2
Serious $1,300 $650 Apr 30, 1998 Closed
No citations from this inspection.
No citations from this inspection.
Citation and rule Type Proposed Current Issued Status Citation 1, item 1a
Serious $1,300 $650 Jan 30, 1998 Closed Citation 1, item 1b
Serious $0 $0 Jan 30, 1998 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Repeat $10,000 $6,000 Jan 12, 1998 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $975 $488 Nov 13, 1997 Closed Citation 2, item 1
Other-than-serious $0 $0 Nov 13, 1997 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $1,700 $850 Apr 24, 1997 Closed Citation 1, item 2a
Serious $1,700 $850 Apr 24, 1997 Closed Citation 1, item 2b
Serious $0 $0 Apr 24, 1997 Closed Citation 1, item 2c
Serious $0 $0 Apr 24, 1997 Closed Citation 1, item 2d
Serious $0 $0 Apr 24, 1997 Closed Citation 1, item 3
Serious $1,275 $638 Apr 24, 1997 Closed Citation 1, item 4
Serious $1,275 $638 Apr 24, 1997 Closed Citation 1, item 5
Serious $1,700 $850 Apr 24, 1997 Closed
No citations from this inspection.
No citations from this inspection.
Citation and rule Type Proposed Current Issued Status Citation 1, item 1a
Serious $1,375 $688 Apr 15, 1996 Closed Citation 1, item 1b
Serious $0 $0 Apr 15, 1996 Closed Citation 2, item 1a
Serious $412 $412 Apr 15, 1996 Closed Citation 2, item 1b
Serious $0 $0 Apr 15, 1996 Closed
No citations from this inspection.
No citations from this inspection.
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $1,700 $850 Jul 21, 1995 Closed
No citations from this inspection.
No citations from this inspection.
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $825 $825 Nov 9, 1993 Closed Citation 2, item 1
Other-than-serious $0 $0 Nov 9, 1993 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1a
Serious $1,300 $780 Apr 6, 1993 Closed Citation 1, item 1b
Serious $0 $0 Apr 6, 1993 Closed Citation 1, item 2
Serious $975 $585 Apr 6, 1993 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $1,300 $780 Apr 6, 1993 Closed
Inspection 17941477 OPENED FEB 4, 1993 Closed Complaint · Partial · Health · 20 employees at the site · Closed Mar 1, 1993
Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
No citations from this inspection.
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $975 $650 Aug 14, 1991 Closed Citation 1, item 2a
Serious $4,000 $2,665 Aug 14, 1991 Closed Citation 1, item 2b
Serious $0 $0 Aug 14, 1991 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 2
Serious $500 $400 Sep 25, 1990 Closed Citation 2, item 1
Repeat $1,400 $1,120 Sep 25, 1990 Closed Citation 2, item 2
Repeat $2,000 $1,600 Sep 25, 1990 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $450 $300 Apr 3, 1990 Closed Citation 1, item 2
Serious $180 $120 Apr 3, 1990 Closed Citation 1, item 3
Serious $360 $240 Apr 3, 1990 Closed Citation 1, item 4
Serious $540 $270 Apr 3, 1990 Closed Citation 1, item 5
Serious $540 $270 Apr 3, 1990 Closed Citation 2, item 1
Other-than-serious $0 $0 Apr 3, 1990 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 2
Serious $360 $360 Mar 16, 1990 Closed Citation 1, item 3
Serious $630 $315 Mar 16, 1990 Closed Citation 1, item 4
Serious $1,000 $1,000 Mar 16, 1990 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Other-than-serious $400 $0 Oct 26, 1988 Final Citation 2, item 1
Serious $2,000 $1,000 Oct 26, 1988 Final
Citation and rule Type Proposed Current Issued Status Citation 2, item 1
Other-than-serious $0 $0 Jul 25, 1988 Contested Citation 2, item 2
Other-than-serious $0 $0 Jul 25, 1988 Contested Citation 2, item 3
Other-than-serious $0 $0 Jul 25, 1988 Contested
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Serious $1,000 $600 Jun 24, 1988 Closed Citation 2, item 1
Other-than-serious $0 $0 Jun 24, 1988 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Other-than-serious $0 $0 Jul 21, 1987 Closed
No citations from this inspection.
No citations from this inspection.
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Other-than-serious $0 $0 Oct 1, 1985 Closed Citation 1, item 2
Other-than-serious $0 $0 Oct 1, 1985 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Other-than-serious $0 $0 Aug 6, 1975 Closed Citation 1, item 2
Other-than-serious $40 $40 Aug 6, 1975 Closed Citation 1, item 3
Other-than-serious $0 $0 Aug 6, 1975 Closed Citation 1, item 4
Other-than-serious $0 $0 Aug 6, 1975 Closed Citation 1, item 5
Other-than-serious $0 $0 Aug 6, 1975 Closed Citation 1, item 6
Other-than-serious $0 $0 Aug 6, 1975 Closed
Citation and rule Type Proposed Current Issued Status Citation 1, item 1
Other-than-serious $0 $0 Jun 10, 1975 Closed Citation 1, item 2
Other-than-serious $0 $0 Jun 10, 1975 Closed Citation 1, item 3
Other-than-serious $0 $0 Jun 10, 1975 Closed Citation 1, item 4
Other-than-serious $0 $0 Jun 10, 1975 Closed Citation 1, item 5
Other-than-serious $0 $0 Jun 10, 1975 Closed Citation 1, item 6
Other-than-serious $0 $0 Jun 10, 1975 Closed Citation 1, item 7
Other-than-serious $0 $0 Jun 10, 1975 Closed Citation 1, item 8
Other-than-serious $0 $0 Jun 10, 1975 Closed Citation 1, item 9
Other-than-serious $55 $55 Jun 10, 1975 Closed
Injury and illness logs From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2021, the Warwick site logged 5 recordable injuries or illnesses among about 225 workers: 2.4 per 100 full-time workers, against a median of 2.2 for its industry. Those cases cost 74 days away from work.
Site and year Workers Cases Days-away cases Rate Industry median Cardi CorporationWarwick · 2021
225
5 2 2.4 2.2 Rhode Island Construction managementWarwick · 2021
34
0 0 0.0 2.2 Cardi LeasingWarwick · 2017
20
0 0 0.0 0.0
Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in .
See plans Severe injury reports Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Apr 7, 2015, Providence: Hospitalization · cuts, lacerations · finger(s), fingernail(s), n.e.c.
An employee was cutting a wooden 2-by-4 board. As he cut close to his hand, the saw kicked back and pulled his gloved thumb into the blade, severely cutting his thumb just below the nail.
The rules behind these citations Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(3)(ii)
(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.” 29 CFR 1910.106(e)(2)(ii)
(ii) Containers. Flammable liquids shall be stored in tanks or closed containers. 29 CFR 1910.107 · Spray painting and finishing29 CFR 1910.107(c)(5)
(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections. 29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart
Other highway, street, and bridge construction employers in Rhode Island Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans .
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us .