OSHA has inspected Chemart Company 8 times in Rhode Island since 1983.
The latest one began on Oct 4, 2021 after a fatality or catastrophe, in Lincoln.
Those inspections ended with 46 citation items: 33 serious and 13 other-than-serious.
Penalties were first proposed at $48,120 and now stand at $24,494, 49% lower after settlements or reviews.
Respiratory protection comes up most often in these citations: 8 items under 1910.134.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Chemart Company averages $6,149 (2 cited inspections).
1 inspection on this page followed a fatal incident.
Chemart Company also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Rhode Island · latest 90 days of OSHA records
81employers cited
Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.
Incident on Oct 2, 2021 (fatal): Employee is killed when caught in polishing machine
At 7:15 a.m on October 2, 2021, an employee was applying buffing compound to the buffing wheels of a polishing machine. The employee became caught in the buffing wheels, pulling him into the polishing machine, striking his head and upper torso against the front of the machine, causing fatal injuries.
Referral · Partial · Health · 90 employees at the site · Closed Nov 30, 2021
11 New England Way, Lincoln, RI 02865 · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · OSHA's record · Phone and website on Google Maps
Planned · Partial · Health · 80 employees at the site · Closed Apr 6, 2017
11 New England Way, Lincoln, RI 02865 · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 314920836 OPENED JAN 19, 2012Closed
Planned · Partial · Safety · 78 employees at the site · Closed Jun 6, 2012
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Lincoln site logged 1 recordable injury or illness among about 170 workers: 0.6 per 100 full-time workers, against a median of 3.2 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
ChemArt Company
Lincoln · 2024
170
1
0
0.6
3.2
Included with any plan: 3 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards
29 CFR 1903.2(a)(1)
(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
29 CFR 1910.106(d)(4)(iv)
(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.
Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.