OSHA SearchOSHA records by employer

Chemo Dynamics Inc.: OSHA inspections and violations

Sayreville, New Jersey · Commercial and Institutional Building Construction · NAICS 236220

6inspections
58citation items
$40,212current penalties
Feb 5, 2018last inspection

OSHA has inspected Chemo Dynamics Inc. 6 times in New Jersey since 1992.

The latest one began on Feb 5, 2018 as part of a related case, in Sayreville.

Those inspections ended with 58 citation items: 47 serious and 11 other-than-serious.

Penalties were first proposed at $61,707 and now stand at $40,212, 35% lower after settlements or reviews.

Flammable liquids comes up most often in these citations: 8 items under 1910.106.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Chemo Dynamics Inc. averages $7,761 (2 cited inspections).

Chemo Dynamics Inc.: OSHA citation items per year, 1992 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Chemo Dynamics Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342946662 OPENED FEB 5, 2018Closed

Unprogrammed related · Partial · Health · 7 employees at the site · Closed Aug 1, 2019

3 Crossman Road South, Sayreville, NJ 08871 · Research and Development in the Physical, Engineering, and Life Sciences · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$2,956$2,217Aug 3, 2018Final
Citation 1, item 1b
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Aug 3, 2018Final
Citation 1, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$5,175$3,881Aug 3, 2018Final
Citation 1, item 3a
29 CFR 1926.62(d)(1)(i) · Lead in construction
Serious$4,434$3,326Aug 3, 2018Final
Citation 1, item 3b
29 CFR 1926.62(d)(2)(v) · Lead in construction
Serious$0$0Aug 3, 2018Final
Citation 1, item 4
29 CFR 1926.1101(k)(2)(ii) · Asbestos in construction
Serious$5,175$3,881Aug 3, 2018Final

Inspection 342946621 OPENED JAN 31, 2018Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed Aug 29, 2018

3 Crossman Road South, Sayreville, NJ 08871 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$2,217$2,217Jun 14, 2018Final

Inspection 113764609 OPENED DEC 13, 1995Closed

Referral · Partial · Health · 7 employees at the site · Closed Feb 15, 1996

3 Crossman Rd., South, Sayreville, NJ 08865 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 113763973 OPENED JAN 23, 1995Closed

Referral · Partial · Health · 3,200 employees at the site · Closed Sep 29, 1995

3 Crossman Rd., South, Sayreville, NJ 08865 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109041871 OPENED MAR 26, 1993Closed

Referral · Complete · Health · 13 employees at the site · Closed Apr 10, 1997

3 Crossman Road South, Sayreville, NJ 08872 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$800$200Aug 24, 1993Final
Citation 1, item 3
29 CFR 1910.24(i) · Fixed industrial stairs
Other-than-serious$800$200Aug 24, 1993Final
Citation 1, item 4
29 CFR 1910.36(b)(2) · Exit route design
Other-than-serious$2,000$200Aug 24, 1993Final
Citation 1, item 5
29 CFR 1910.36(b)(4) · Exit route design
Serious$2,000$1,500Aug 24, 1993Final
Citation 1, item 6a
29 CFR 1910.36(b)(8) · Exit route design
Serious$2,000$1,450Aug 24, 1993Final
Citation 1, item 6b
29 CFR 1910.37(f)(2) · Exit routes
Serious$0$0Aug 24, 1993Final
Citation 1, item 7a
29 CFR 1910.37(q)(1) · Exit routes
Serious$2,000$1,000Aug 24, 1993Final
Citation 1, item 7b
29 CFR 1910.37(q)(2) · Exit routes
Serious$0$0Aug 24, 1993Final
Citation 1, item 8a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$1,000$750Aug 24, 1993Final
Citation 1, item 8b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Aug 24, 1993Final
Citation 1, item 10
29 CFR 1910.134(e)(3) · Respiratory protection
Other-than-serious$2,000$200Aug 24, 1993Final
Citation 1, item 11
29 CFR 1910.157(d)(1) · Portable fire extinguishers
Serious$2,000$1,500Aug 24, 1993Final
Citation 1, item 12
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$1,000$500Aug 24, 1993Final
Citation 1, item 13
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$1,500$1,500Aug 24, 1993Final
Citation 1, item 14a
29 CFR 1910.1200(h)(2)(i) · Hazard communication
Serious$2,000$1,500Aug 24, 1993Final
Citation 1, item 14b
29 CFR 1910.1450(f)(4)(ia) · Occupational exposure to hazardous chemicals in laboratories
Serious$0$0Aug 24, 1993Final
Citation 1, item 14c
29 CFR 1910.1200(h)(2)(ii) · Hazard communication
Serious$0$0Sep 23, 1994Closed
Citation 1, item 14d
29 CFR 1910.1450(f)(4)(ic) · Occupational exposure to hazardous chemicals in laboratories
Serious$0$0Sep 23, 1994Closed
Citation 1, item 14e
29 CFR 1910.1450(e)(3)(ii) · Occupational exposure to hazardous chemicals in laboratories
Serious$0$0Sep 23, 1994Closed
Citation 1, item 17a
OSH Act Section 5(a)(1) · General Duty Clause
Serious$1,500$1,500Sep 23, 1994Closed
Citation 1, item 17b
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$0$0Sep 23, 1994Closed
Citation 2, item 1
29 CFR 1910.24(f) · Fixed industrial stairs
Other-than-serious$0$0Aug 24, 1993Final
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Aug 24, 1993Final

Inspection 102915725 OPENED AUG 6, 1992Closed

Referral · Complete · Health · 14 employees at the site · Closed Jan 9, 1995

3 Crossman Road South, Sayreville, NJ 08872 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$1,500$900Dec 14, 1992Closed
Citation 1, item 2
29 CFR 1910.22(c) · General requirements
Serious$600$360Dec 14, 1992Closed
Citation 1, item 3
29 CFR 1910.36(b)(8) · Exit route design
Serious$1,500$900Dec 14, 1992Closed
Citation 1, item 4a
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$1,500$900Dec 14, 1992Closed
Citation 1, item 4b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Dec 14, 1992Closed
Citation 1, item 5a
29 CFR 1910.106(d)(4)(v) · Flammable liquids
Serious$1,500$900Dec 14, 1992Closed
Citation 1, item 5b
29 CFR 1910.106(d)(4)(v) · Flammable liquids
Serious$0$0Dec 14, 1992Closed
Citation 1, item 6
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$1,500$900Dec 14, 1992Closed
Citation 1, item 7
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$1,500$900Dec 14, 1992Closed
Citation 1, item 8
29 CFR 1910.120(g)(2)(xi) · Hazardous waste operations and emergency response
Serious$1,500$900Dec 14, 1992Closed
Citation 1, item 9a
29 CFR 1910.134(b)(5) · Respiratory protection
Serious$1,050$630Dec 14, 1992Closed
Citation 1, item 9b
29 CFR 1910.134(b)(6) · Respiratory protection
Serious$0$0Dec 14, 1992Closed
Citation 1, item 10
29 CFR 1910.134(e)(3) · Respiratory protection
Serious$1,500$900Dec 14, 1992Closed
Citation 1, item 11
29 CFR 1910.134(f)(2)(ii) · Respiratory protection
Serious$750$450Dec 14, 1992Closed
Citation 1, item 12a
29 CFR 1910.179(d)(3)(iii) · Overhead and gantry cranes
Serious$750$450Dec 14, 1992Closed
Citation 1, item 12b
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Serious$0$0Dec 14, 1992Closed
Citation 1, item 13
29 CFR 1910.212(a)(5) · Machine guarding
Serious$750$450Dec 14, 1992Closed
Citation 1, item 14
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$750$450Dec 14, 1992Closed
Citation 1, item 15
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$1,500$900Dec 14, 1992Closed
Citation 1, item 16a
29 CFR 1910.1200(h)(2)(ii) · Hazard communication
Serious$1,500$900Dec 14, 1992Closed
Citation 1, item 16b
29 CFR 1910.1450(f)(4)(ia) · Occupational exposure to hazardous chemicals in laboratories
Serious$0$0Dec 14, 1992Closed
Citation 1, item 16c
29 CFR 1910.1450(f)(3)(i) · Occupational exposure to hazardous chemicals in laboratories
Serious$0$0Dec 15, 1992Closed
Citation 1, item 17
29 CFR 1910.1450(e)(1) · Occupational exposure to hazardous chemicals in laboratories
Serious$1,500$900Dec 15, 1992Closed
Citation 2, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$0$0Dec 15, 1992Closed
Citation 2, item 2
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Dec 15, 1992Closed
Citation 2, item 3 Other-than-serious$0$0Dec 15, 1992Closed
Citation 2, item 4
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 15, 1992Closed
Citation 2, item 5
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Dec 15, 1992Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.1450 · Occupational exposure to hazardous chemicals in laboratories

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.20

29 CFR 1910.212 · Machine guarding

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1926.1101 · Asbestos in construction

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.62 · Lead in construction

OSH Act Section 5 · General Duty Clause

Other commercial and institutional building construction employers in New Jersey

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.