8inspections
36citation items
$46,034current penalties
Jan 4, 2019last inspection

Clinton Industries, Inc. has 8 OSHA inspections on record in Pennsylvania, the first in 1997.

OSHA's last visit started on Jan 4, 2019 to follow up on an earlier case, in York.

Across those inspections OSHA issued 36 citation items: 25 serious and 11 other-than-serious.

OSHA proposed $77,736 in penalties. After settlements and reviews the total is $46,034, down 41%.

Most often, OSHA cited 1910.305, electrical wiring methods (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Clinton Industries, Inc. averages $7,339 over 6 cited inspections in that time.

Clinton Industries, Inc. also files yearly injury logs with OSHA, summarized below.

Clinton Industries, Inc.: OSHA citation items per year, 1997 to 2019
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Clinton Industries, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343696191 OPENED JAN 4, 2019Closed

Follow-up · Partial · Health · 21 employees at the site · Closed Jan 30, 2019

1140 Edison Street, York, PA 17403 · Institutional Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342398914 OPENED JUN 15, 2017Closed

Complaint · Partial · Health · 16 employees at the site · Closed Mar 8, 2018

1140 Edison Street, York, PA 17403 · Institutional Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$7,171$6,095Aug 22, 2017Final

Inspection 342403177 OPENED JUN 15, 2017Closed

Follow-up · Partial · Health · 16 employees at the site · Closed Sep 15, 2017

1140 Edison Street, York, PA 17403 · Institutional Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Aug 22, 2017Final
Citation 1, item 2 Other-than-serious$0$0Aug 22, 2017Final

Inspection 342403300 OPENED JUN 15, 2017Closed

Follow-up · Partial · Safety · 16 employees at the site · Closed Sep 29, 2017

1140 Edison Street, York, PA 17403 · Institutional Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.110(b)(10)(ix) · Storage and handling of liquefied petroleum gases
Other-than-serious$9,778$0Aug 22, 2017Final
Citation 1, item 2
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$9,778$9,778Aug 22, 2017Final
Citation 1, item 3a
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$9,778$5,222Aug 22, 2017Final
Citation 1, item 3b
29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods
Other-than-serious$0$0Aug 22, 2017Final
Citation 2, item 1
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Aug 22, 2017Final

Inspection 341611614 OPENED JUL 11, 2016Closed

Complaint · Partial · Health · 120 employees at the site · Closed Feb 3, 2017

525 East Market Street, York, PA 17403 · Institutional Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$4,089$2,453Dec 30, 2016Final
Citation 1, item 1b
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$0$0Dec 30, 2016Final
Citation 1, item 2a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$4,089$2,453Dec 30, 2016Final
Citation 1, item 2b
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Dec 30, 2016Final
Citation 1, item 3
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$4,089$2,453Dec 30, 2016Final
Citation 1, item 4
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$4,089$2,455Dec 30, 2016Final

Inspection 340919729 OPENED SEP 15, 2015Closed

Complaint · Partial · Safety · 100 employees at the site · Closed Apr 5, 2016

1140 Edison Street, York, PA 17403 · Institutional Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Serious$3,500$2,100Feb 12, 2016Final
Citation 1, item 2a
29 CFR 1910.37(a)(3) · Exit routes
Serious$2,100$1,260Feb 12, 2016Final
Citation 1, item 2c
29 CFR 1910.37(b)(4) · Exit routes
Serious$0$0Feb 12, 2016Final
Citation 1, item 3a
29 CFR 1910.110(b)(10)(ix) · Storage and handling of liquefied petroleum gases
Serious$2,800$1,680Feb 12, 2016Final
Citation 1, item 3b
29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags
Serious$0$0Feb 12, 2016Final
Citation 1, item 4
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$4,900$2,940Feb 12, 2016Final
Citation 1, item 5
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$3,500$2,100Feb 12, 2016Final
Citation 1, item 6a
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$2,100$1,260Feb 12, 2016Final
Citation 1, item 6b
29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods
Serious$0$0Feb 12, 2016Final
Citation 2, item 1
29 CFR 1904.7(b)(4)(xi) · General recording criteria
Other-than-serious$0$0Feb 12, 2016Final
Citation 2, item 2
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Feb 12, 2016Final
Citation 2, item 3
29 CFR 1910.136(a) · Foot protection
Other-than-serious$0$0Feb 12, 2016Final

Inspection 340920719 OPENED SEP 15, 2015Closed

Complaint · Partial · Health · 100 employees at the site · Closed Apr 5, 2016

1140 Edison Street, York, PA 17403 · Institutional Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,975$1,785Feb 12, 2016Final

Inspection 116156860 OPENED AUG 22, 1997Closed

Complaint · Partial · Safety · 25 employees at the site · Closed Jan 5, 1998

545 South Pine Street, York, PA 17403 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(2)(ivc) · Flammable liquids
Serious$600$400Oct 1, 1997Closed
Citation 1, item 2
29 CFR 1910.110(f)(4)(i) · Storage and handling of liquefied petroleum gases
Serious$600$400Oct 1, 1997Closed
Citation 1, item 3a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$600$500Oct 1, 1997Closed
Citation 1, item 3b
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$0$0Oct 1, 1997Closed
Citation 1, item 3c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Oct 1, 1997Closed
Citation 1, item 4
29 CFR 1910.213(b)(3) · Woodworking machinery
Serious$600$400Oct 1, 1997Closed
Citation 1, item 5a
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$600$300Oct 1, 1997Closed
Citation 2, item 1
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 1, 1997Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 1, 1997Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the York site logged 4 recordable injuries or illnesses among about 70 workers: 4.9 per 100 full-time workers, against a median of 3.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Market St.
York · 2025
70 404.93.7
Hartman St.
York · 2025
20 000.03.7
Edison St.
York · 2022
20 105.03.7
Pine St.
York · 2018
12 000.03.7

Included with any plan: 21 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.7 · General recording criteria

29 CFR 1904.7(b)(4)(xi)

(xi) How do I count days of job transfer or restriction? You count days of job transfer or restriction in the same way you count days away from work, using § 1904.7(b)(3)(i) to (viii), above. The only difference is that, if you permanently assign the injured or ill employee to a job that has been modified or permanently changed in a manner that eliminates the routine functions the employee was restricted from performing, you may stop the day count when the modification or change is made permanent. You must count at least one day of restricted work or job transfer for such cases.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ivc)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.136 · Foot protection

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.22 · General requirements

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

OSH Act Section 5 · General Duty Clause

Other institutional furniture manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.