Coastline Electric Inc: OSHA inspections and violations

Conway, South Carolina · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

5inspections
5citation items
$835current penalties
Sep 13, 2017last inspection

Coastline Electric Inc has 5 OSHA inspections on record in South Carolina, the first in 2007.

OSHA's last visit started on Sep 13, 2017 as a planned inspection, in Conway.

Across those inspections OSHA issued 5 citation items: 5 serious.

OSHA proposed $1,225 in penalties. After settlements and reviews the total is $835, down 32%.

Most often, OSHA cited 1926.405, job-site wiring (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Coastline Electric Inc averages $375 over 1 cited inspection in that time.

Coastline Electric Inc: OSHA citation items per year, 2007 to 2017
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

42employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Coastline Electric Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342646411 OPENED SEP 13, 2017Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jan 29, 2018

945 Residence Blvd, Conway, SC 29526 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(d) · Job-site wiring
Serious$375$375Nov 21, 2017Final

Inspection 313491433 OPENED NOV 19, 2009Closed

Planned · Complete · Safety · 7 employees at the site · Closed Feb 18, 2010

810 First Ave North, Surfside Beach, SC 29575 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$100$100Jan 25, 2010Closed

Inspection 313485609 OPENED JUL 14, 2009Closed

Planned · Complete · Safety · 6 employees at the site · Closed Oct 5, 2009

529 Browns Ferry Rd, Georgetown, SC 29440 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$150$60Aug 19, 2009Closed
Citation 1, item 2
29 CFR 1926.405(d) · Job-site wiring
Serious$500$200Aug 19, 2009Closed

Inspection 312822919 OPENED FEB 10, 2009Closed

Planned · Complete · Safety · 2 employees at the site · Closed Mar 19, 2009

5000 Claire Chapin Epps Dr, Myrtle Beach, SC 29577 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$100$100Mar 4, 2009Closed

Inspection 311508865 OPENED DEC 28, 2007Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jan 22, 2008

2000 Oakheart Dr, Conway, SC 29526 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other electrical contractors and other wiring installation contractors employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.