OSHA SearchOSHA records by employer

Deering Custom Cabinets, LLC: OSHA inspections and violations

Pensacola, Florida · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

2inspections
13citation items
$3,839current penalties
Oct 12, 2021last inspection

Since 2021, OSHA inspectors have visited Deering Custom Cabinets, LLC in Florida 2 times.

The most recent inspection opened on Oct 12, 2021 to follow up on an earlier case, in Pensacola.

In all, OSHA issued 13 citation items: 9 serious and 4 other-than-serious.

The penalties, $3,839 in total, stand where OSHA first set them.

The rule cited most here is 1910.134 (respiratory protection), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Deering Custom Cabinets, LLC averages $3,839 across 1 cited inspection.

Deering Custom Cabinets, LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Deering Custom Cabinets, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345577043 OPENED OCT 12, 2021Closed

Follow-up · Partial · Health · 8 employees at the site · Closed Sep 1, 2023

8320 Lillian Hwy, Pensacola, FL 32506 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345107213 OPENED JAN 20, 2021Closed

Complaint · Complete · Health · 7 employees at the site · Closed Sep 1, 2023

8320 Lillian Hwy, Pensacola, FL 32506 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,755$1,755Jun 22, 2021Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jun 22, 2021Final
Citation 1, item 1c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Jun 22, 2021Final
Citation 1, item 1d
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Jun 22, 2021Final
Citation 1, item 1e
29 CFR 1910.134(k)(3) · Respiratory protection
Serious$0$0Jun 22, 2021Final
Citation 1, item 2a Serious$1,755$1,755Jun 22, 2021Final
Citation 1, item 2b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Jun 22, 2021Final
Citation 1, item 2c
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$0$0Jun 22, 2021Final
Citation 1, item 2d
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Jun 22, 2021Final
Citation 2, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 22, 2021Final
Citation 2, item 1b
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Jun 22, 2021Final
Citation 2, item 1c
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jun 22, 2021Final
Citation 2, item 2
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$329$329Aug 24, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.94 · Ventilation

Other wood kitchen cabinet and countertop manufacturing employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.