Inspection 349235960 OPENED OCT 21, 2026Open
5186 Woodlane Circle, Tallahassee, FL 32303 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Tallahassee, Florida · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110
Since 2017, OSHA inspectors have visited Woodlane Cabinet Company in Florida 3 times.
The most recent inspection opened on Oct 21, 2026 as a planned inspection, in Tallahassee and is still open.
In all, OSHA issued 12 citation items: 10 serious and 2 other-than-serious.
The proposed penalties came to $23,293; today they stand at $13,973, 40% less.
The rule cited most here is 1910.134 (respiratory protection), 4 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Woodlane Cabinet Company averages $6,987 across 2 cited inspections.
Florida · latest 90 days of OSHA records
316employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Florida
Checking a subcontractor, a client or your own company? Watch Woodlane Cabinet Company and get notified the morning OSHA posts a new citation for it.
Watch this company5186 Woodlane Circle, Tallahassee, FL 32303 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
5186 Woodlane Circle, Tallahassee, FL 32303 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(c)(6) · Spray painting and finishing |
Serious | $3,802 | $2,280 | May 12, 2017 | Final |
| Citation 1, item 2a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $3,802 | $2,280 | May 12, 2017 | Final |
| Citation 1, item 2b 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | May 12, 2017 | Final |
| Citation 1, item 2c 29 CFR 1910.134(f)(1) · Respiratory protection |
Serious | $0 | $0 | May 12, 2017 | Final |
| Citation 1, item 2d 29 CFR 1910.134(k)(3) · Respiratory protection |
Serious | $0 | $0 | May 12, 2017 | Final |
5186 Woodlane Circle, Tallahassee, FL 32303 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $4,310 | $3,139 | Apr 4, 2017 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $5,387 | $3,137 | Apr 4, 2017 | Final |
| Citation 1, item 3a 29 CFR 1910.213(c)(1) · Woodworking machinery |
Serious | $5,387 | $3,137 | Apr 4, 2017 | Final |
| Citation 1, item 3b 29 CFR 1910.213(c)(2) · Woodworking machinery |
Serious | $0 | $0 | Apr 4, 2017 | Final |
| Citation 1, item 3c 29 CFR 1910.213(c)(3) · Woodworking machinery |
Serious | $0 | $0 | Apr 4, 2017 | Final |
| Citation 2, item 1 29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Apr 4, 2017 | Final |
| Citation 2, item 2 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $605 | $0 | Apr 4, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(c)(6)
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.134(c)(1)
(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.