OSHA SearchOSHA records by employer

East Coast Cabinetry, Inc.: OSHA inspections and violations

Ozone Park, New York · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

2inspections
14citation items
$25,365current penalties
Dec 3, 2021last inspection

East Coast Cabinetry, Inc. has 2 OSHA inspections on record in New York, the first in 2021.

OSHA's last visit started on Dec 3, 2021 as part of a related case, in Ozone Park.

Across those inspections OSHA issued 14 citation items: 14 serious.

OSHA proposed $42,265 in penalties. After settlements and reviews the total is $25,365, down 40%.

Most often, OSHA cited 1910.134, respiratory protection (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. East Coast Cabinetry, Inc. averages $12,682 over 2 cited inspections in that time.

East Coast Cabinetry, Inc.: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

372employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch East Coast Cabinetry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345667489 OPENED DEC 3, 2021Closed

Unprogrammed related · Partial · Safety · 14 employees at the site · Closed Jan 24, 2023

9308 95th Avenue, Ozone Park, NY 11416 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a)(3) · Exit routes
Serious$4,144$2,480May 27, 2022Final
Citation 1, item 2
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$2,486$1,500May 27, 2022Final
Citation 1, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$2,486$1,500May 27, 2022Final
Citation 1, item 4
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$4,144$2,480May 27, 2022Final
Citation 1, item 5
29 CFR 1910.242(b) · Hand and power tools
Serious$4,144$2,480May 27, 2022Final
Citation 1, item 6
29 CFR 1910.305(c)(4) · Electrical wiring methods
Serious$2,486$1,500May 27, 2022Final

Inspection 345667703 OPENED DEC 3, 2021Closed

Complaint · Complete · Health · 8 employees at the site · Closed Jan 11, 2023

93-08 95th Avenue, Ozone Park, NY 11416 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$5,801$3,480May 27, 2022Final
Citation 1, item 2
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$5,801$3,480May 27, 2022Final
Citation 1, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$5,801$3,480May 27, 2022Final
Citation 1, item 3b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0May 27, 2022Final
Citation 1, item 3c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0May 27, 2022Final
Citation 1, item 3d
29 CFR 1910.134(k)(3) · Respiratory protection
Serious$0$0May 27, 2022Final
Citation 1, item 4a
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Serious$4,972$2,985May 27, 2022Final
Citation 1, item 4b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0May 27, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(g)(2)

(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other wood kitchen cabinet and countertop manufacturing employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.