OSHA SearchOSHA records by employer

Gardner Manufacturing Company: OSHA inspections and violations

Horicon, Wisconsin · Sheet Metal Work Manufacturing · NAICS 332322

6inspections
20citation items
$26,342current penalties
Jan 29, 2025last inspection

Gardner Manufacturing Company has 6 OSHA inspections on record in Wisconsin, the first in 1994.

OSHA's last visit started on Jan 29, 2025 after a complaint, in Horicon.

Across those inspections OSHA issued 20 citation items: 17 serious and 3 other-than-serious.

OSHA proposed $39,124 in penalties. After settlements and reviews the total is $26,342, down 33%.

Most often, OSHA cited 1910.1200, hazard communication (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Gardner Manufacturing Company averages $7,542 over 1 cited inspection in that time.

Gardner Manufacturing Company also files yearly injury logs with OSHA, summarized below.

Gardner Manufacturing Company: OSHA citation items per year, 1994 to 2025
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

218employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Gardner Manufacturing Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348009119 OPENED JAN 29, 2025Closed

Complaint · Partial · Health · 78 employees at the site · Closed Jun 3, 2025

1201 W. Lake Street, Horicon, WI 53032 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342124526 OPENED FEB 21, 2017Closed

Complaint · Partial · Health · 94 employees at the site · Closed Apr 2, 2018

1201 W Lake Street, Horicon, WI 53032 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$5,387$3,772Aug 11, 2017Final
Citation 1, item 2a
29 CFR 1910.134(i)(7) · Respiratory protection
Serious$5,387$3,770Aug 11, 2017Final
Citation 1, item 2b
29 CFR 1910.134(l)(1) · Respiratory protection
Serious$0$0Aug 11, 2017Final

Inspection 313136608 OPENED DEC 22, 2010Closed

Planned · Partial · Safety · 111 employees at the site · Closed May 17, 2011

1201 W. Lake Street, Horicon, WI 53032 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$2,100$1,400Mar 21, 2011Closed
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,800$1,900Mar 21, 2011Closed
Citation 1, item 4
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$2,800$1,900Mar 21, 2011Closed
Citation 1, item 6
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$2,100$1,400Mar 21, 2011Closed

Inspection 313136616 OPENED DEC 22, 2010Closed

Planned · Partial · Health · 111 employees at the site · Closed Jun 8, 2011

2101 W. Lake Street, Horicon, WI 53032 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.252(c)(6)(ii) · Welding fire safety
Other-than-serious$2,100$1,400Mar 21, 2011Closed
Citation 1, item 2
29 CFR 1910.1026(d)(2)(i) · Hexavalent chromium
Serious$2,100$1,400Mar 21, 2011Closed
Citation 1, item 3a
29 CFR 1910.1026(l)(2)(i) · Hexavalent chromium
Serious$2,100$1,400Mar 21, 2011Closed
Citation 1, item 3b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Mar 21, 2011Closed

Inspection 303869754 OPENED OCT 28, 2002Closed

Planned · Partial · Safety · 98 employees at the site · Closed Nov 4, 2002

1201 W. Lake Street, Horicon, WI 53032 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 122461262 OPENED OCT 4, 1994Closed

Complaint · Partial · Health · 110 employees at the site · Closed Dec 30, 1994

1201 W. Lake Street, Horicon, WI 53032 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$1,400$910Oct 17, 1994Closed
Citation 1, item 2a
29 CFR 1910.151(c) · First aid and eyewash
Serious$3,500$2,275Oct 17, 1994Closed
Citation 1, item 2b
29 CFR 1910.132(c) · Personal protective equipment, general requirements
Serious$0$0Oct 17, 1994Closed
Citation 1, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$1,400$910Oct 17, 1994Closed
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,450$1,590Oct 17, 1994Closed
Citation 1, item 5
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$1,050$685Oct 17, 1994Closed
Citation 1, item 6
29 CFR 1910.1200(h) · Hazard communication
Serious$2,450$1,630Oct 17, 1994Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Oct 17, 1994Closed
Citation 2, item 2
29 CFR 1910.38(a)(1) · Emergency action plans
Other-than-serious$0$0Oct 17, 1994Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Horicon site logged 9 recordable injuries or illnesses among about 66 workers: 13.4 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 87 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Gardner Manufacturing Company
Horicon · 2024
66 9313.43.6
Gardner Manufacturing Company - EL
Horicon · 2024
5 000.01.9

Included with any plan: 5 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(2)(i)

(2) Scheduled monitoring option. (i) The employer shall perform initial monitoring to determine the 8-hour TWA exposure for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area. Where an employer does representative sampling instead of sampling all employees in order to meet this requirement, the employer shall sample the employee(s) expected to have the highest chromium (VI) exposures.

29 CFR 1910.1026(l)(2)(i)

(2) Employee information and training. (i) The employer shall ensure that each employee can demonstrate knowledge of at least the following:

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.38 · Emergency action plans

OSH Act Section 5 · General Duty Clause

Other sheet metal work manufacturing employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.