OSHA SearchOSHA records by employer

Gpe Controls: OSHA inspections and violations

Morton Grove, Illinois · Other Measuring and Controlling Device Manufacturing · NAICS 334519

4inspections
27citation items
$17,400current penalties
Aug 30, 2017last inspection

Gpe Controls has 4 OSHA inspections on record in Illinois, the first in 1976.

OSHA's last visit started on Aug 30, 2017 to monitor an earlier case, in Hillside.

Across those inspections OSHA issued 27 citation items: 11 serious and 16 other-than-serious.

OSHA proposed $34,039 in penalties. After settlements and reviews the total is $17,400, down 49%.

Most often, OSHA cited 1910.94, ventilation (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Gpe Controls averages $16,000 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Gpe Controls also files yearly injury logs with OSHA, summarized below.

Gpe Controls: OSHA citation items per year, 1976 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Gpe Controls again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342600905 OPENED AUG 30, 2017Closed

Monitoring · Partial · Safety · 80 employees at the site · Closed Sep 27, 2017

5911 Butterfiled Road, Hillside, IL 60162 · Other Measuring and Controlling Device Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342237005 OPENED APR 7, 2017Closed

Planned · Partial · Safety · 80 employees at the site · Closed Jul 28, 2017

5911 Butterfiled Road, Hillside, IL 60162 · Other Measuring and Controlling Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$8,873$8,873May 22, 2017Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$8,873$0May 22, 2017Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$8,873$4,438May 22, 2017Final
Citation 1, item 4
29 CFR 1910.242(b) · Hand and power tools
Serious$5,070$2,689May 22, 2017Final

Inspection 1330703 OPENED OCT 9, 1984Closed

Accident · Partial · Health · 230 employees at the site · Closed Mar 7, 1985

6511 Oakton St, Morton Grove, IL 60053 · OSHA's record · Phone and website on Google Maps

Incident on Oct 7, 1984 (fatal): Inhalation of vapors in a confined space

EMPLOYEE #1 WAS ASSIGNED TO DRAIN AND CLEAN A BARON BLAKESLEE DEGREASER. THE DEG REASER WAS SURROUNDED BY A 3-1/2 FOOT DEEP PIT, WHICH THE EMPLOYEE ENTERED TO OP EN THE VALUE AND DRAIN THE CONTENTS (METHYLENE CHLORIDE). THE EMPLOYEE WORE A DU ST MUSK IN THE PIT. NO VENTILATING WAS DONE BEFORE ENTERING. NO MEASUREMENTS WER E TAKEN TO DETERMINE AIR CONTAMINANT LEVELS. NO OTHER PERSONNEL WERE PRESENT. TH E EMPLOYEE WAS NOT TRAINED. THE EMPLOYEE WAS FOUND 1 HOUR LATER BY THE SUPERVISO R. HE WAS PRONOUNCED DEAD 2 HOURS LATER.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
OSH Act Section 5(a)(1) · General Duty Clause
Serious$700$500Feb 11, 1985Closed
Citation 1, item 1b Serious$0$0Feb 11, 1985Closed
Citation 1, item 2 Serious$500$250Feb 11, 1985Closed
Citation 1, item 3a Serious$500$250Feb 11, 1985Closed
Citation 1, item 3b Serious$0$0Feb 11, 1985Closed
Citation 1, item 3c Serious$0$0Feb 11, 1985Closed
Citation 1, item 4
29 CFR 1910.134(c) · Respiratory protection
Serious$500$250Feb 11, 1985Closed

Inspection 214757312 OPENED FEB 23, 1976Closed

Planned · Complete · Safety · 241 employees at the site · Closed Jun 10, 1976

6511 Oakton Street, Morton Grove, IL 60053 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(2)(iva) · Flammable liquids
Other-than-serious$0$0Mar 25, 1976Closed
Citation 1, item 2
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Other-than-serious$30$30Mar 25, 1976Closed
Citation 1, item 3
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 25, 1976Closed
Citation 1, item 4
29 CFR 1910.157(a)(5) · Portable fire extinguishers
Other-than-serious$0$0Mar 25, 1976Closed
Citation 1, item 5 Other-than-serious$30$30Mar 25, 1976Closed
Citation 1, item 6
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Mar 25, 1976Closed
Citation 1, item 7
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$30$30Mar 25, 1976Closed
Citation 1, item 8
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Other-than-serious$0$0Mar 25, 1976Closed
Citation 1, item 9
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 25, 1976Closed
Citation 1, item 10
29 CFR 1910.26(a)(5)(v) · Portable metal ladders
Other-than-serious$30$30Mar 25, 1976Closed
Citation 1, item 11
29 CFR 1910.213(p)(4) · Woodworking machinery
Other-than-serious$0$0Mar 25, 1976Closed
Citation 1, item 12
29 CFR 1910.252(c)(2)(vi) · Welding fire safety
Other-than-serious$0$0Mar 25, 1976Closed
Citation 1, item 13 Other-than-serious$0$0Mar 25, 1976Closed
Citation 1, item 14
29 CFR 1910.36(d)(1) · Exit route design
Other-than-serious$0$0Mar 25, 1976Closed
Citation 1, item 15
29 CFR 1910.107(c)(6) · Spray painting and finishing
Other-than-serious$30$30Mar 25, 1976Closed
Citation 1, item 16
29 CFR 1910.145(c)(2)(i) · Specifications for accident prevention signs and tags
Other-than-serious$0$0Mar 25, 1976Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Hillside site logged 1 recordable injury or illness among about 56 workers: 1.8 per 100 full-time workers, against a median of 0.3 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
GPE Controls, Inc.
Hillside · 2017
56 101.80.3

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(e)(2)(iva)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.26 · Portable metal ladders

29 CFR 1910.309

29 CFR 1910.36 · Exit route design

29 CFR 1910.94 · Ventilation

OSH Act Section 5 · General Duty Clause

Other other measuring and controlling device manufacturing employers in Illinois

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.