GST Manufacturing Ltd: OSHA inspections and violations
Haltom City, Texas · Fabricated Structural Metal Manufacturing · NAICS 332312
5inspections
36citation items
$49,286current penalties
Jan 4, 2022last inspection
GST Manufacturing Ltd has 5 OSHA inspections on record in Texas, the first in 2018.
OSHA's last visit started on Jan 4, 2022 to follow up on an earlier case, in Haltom City.
Across those inspections OSHA issued 36 citation items: 31 serious and 5 other-than-serious.
OSHA proposed $118,681 in penalties. After settlements and reviews the total is $49,286, down 58%.
Most often, OSHA cited 1910.134, respiratory protection (5 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. GST Manufacturing Ltd averages $9,857 over 5 cited inspections in that time.
GST Manufacturing Ltd also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Texas · latest 90 days of OSHA records
393employers cited
6 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2019, the Haltom City site logged 16 recordable injuries or illnesses among about 186 workers: 7.8 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 2 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
GST Manufacturing, Ltd.
Haltom City · 2019
186
16
2
7.8
3.6
GST Manufacturing, Ltd
Haltom City · 2017
253
22
2
7.4
3.6
Included with any plan: 1 more yearly log from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”
29 CFR 1910.106(e)(6)(ii)
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.