OSHA SearchOSHA records by employer

Iowa State University: OSHA inspections and violations

Ames, Iowa · Colleges, Universities, and Professional Schools · NAICS 611310

21inspections
72citation items
$109,740current penalties
Sep 4, 2025last inspection

Iowa State University has 21 OSHA inspections on record in Iowa, the first in 1987.

OSHA's last visit started on Sep 4, 2025 after a complaint, in Ames.

Across those inspections OSHA issued 72 citation items: 32 serious, 2 repeat and 38 other-than-serious.

OSHA proposed $202,203 in penalties. After settlements and reviews the total is $109,740, down 46%.

Most often, OSHA cited 1910.134, respiratory protection (17 items).

For context, across all education employers the median penalty per cited inspection since 2015 is $0. Iowa State University averages $17,370 over 4 cited inspections in that time.

Iowa State University also files yearly injury logs with OSHA, summarized below.

Iowa State University: OSHA citation items per year, 1987 to 2025
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

68employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Iowa State University and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348493123 OPENED SEP 4, 2025Closed

Complaint · No inspection · Safety · State government · 1 employee at the site · Closed May 6, 2026

2334 Pammel Dr., Ames, IA 50011 · Colleges, Universities, and Professional Schools · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347928111 OPENED OCT 22, 2024Closed

Unprogrammed related · Partial · Safety · State government · 1 employee at the site · Closed Dec 24, 2024

531 Bissell Road, Ames, IA 50011 · Colleges, Universities, and Professional Schools · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347500258 OPENED MAY 22, 2024Closed

Unprogrammed related · Partial · Safety · State government · 2 employees at the site · Closed Aug 13, 2024

531 Bissell Rd., Ames, IA 50011 · Colleges, Universities, and Professional Schools · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347171993 OPENED DEC 19, 2023Closed

Referral · Partial · Safety · State government · 38 employees at the site · Closed Apr 24, 2024

2408 Wanda Daley Dr, Ames, IA 50011 · Colleges, Universities, and Professional Schools · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Apr 3, 2024Final

Inspection 346971906 OPENED SEP 13, 2023Closed

Referral · Partial · Health · State government · 716 employees at the site · Closed Oct 11, 2023

1800 Christensen Drive, Ames, IA 50011 · Colleges, Universities, and Professional Schools · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345426746 OPENED JUL 15, 2021Closed

Referral · Partial · Safety · State government · 30 employees at the site · Closed Oct 25, 2021

1327 U Avenue, Boone, IA 50036 · Colleges, Universities, and Professional Schools · OSHA's record · Phone and website on Google Maps

Incident on Jul 8, 2021: One employee sustains eye and laceration injuries and anothe

At 3:45 p.m. on July 8, 2021, two employees were transferring a sucrose solution from a fifth PYREX bottle into a tank using an air compressor. They were monitoring the pressure to keep it below 20 PSI when the glass PYREX bottle exploded, shattering and striking the employees with glass fragments. Employee #1 suffered a detached cornea in the left eye and lacerations on the left eye and arm and was hospitalized. Employee #2 sustained facial lacerations requiring 11 stitches and was treated without hospitalization.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 88.4 - CODE OF IOWA (2021)
Other-than-serious$9,753$11,000Sep 24, 2021Final
Citation 1, item 2a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$9,753$11,000Sep 24, 2021Final
Citation 1, item 2b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$9,753$0Sep 24, 2021Final

Inspection 344261888 OPENED AUG 26, 2019Closed

Referral · Partial · Safety · State government · 16,952 employees at the site · Closed Dec 18, 2019

618 Bissell Rd, Ames, IA 50011 · Colleges, Universities, and Professional Schools · OSHA's record · Phone and website on Google Maps

Incident on Aug 22, 2019: Employee fractures bones and suffers cardiac arrest after sh

At 1:15 p.m. on August 22, 2019, an employee was removing fuses from a 4,160-volt substation cabinet. As the employee was removing the canister fuses, his right arm came into contact with the feeder line and his left arm came into contact with the left side of the panel door. This created a circuit and caused the employee to become shocked. The employee suffered electrical shock, fractured ribs, fractured vertebrae, burns to both elbows, and cardiac arrest. The employee was hospitalized for treatment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.269(m)(2)(ii) · Electric power generation, transmission, and distribution
Serious$13,260$13,260Oct 30, 2019Final
Citation 1, item 2a
29 CFR 1910.269(l)(4)(i) · Electric power generation, transmission, and distribution
Serious$13,260$13,260Oct 30, 2019Final
Citation 1, item 2b
29 CFR 1910.269(l)(8)(v) · Electric power generation, transmission, and distribution
Serious$13,260$0Oct 30, 2019Final
Citation 1, item 4
29 CFR 1910.269(n)(2) · Electric power generation, transmission, and distribution
Serious$13,260$13,260Oct 30, 2019Final

Inspection 343807715 OPENED FEB 22, 2019Closed

Referral · Partial · Health · State government · 7 employees at the site · Closed Oct 14, 2019

3726 520th Avenue, Ames, IA 50014 · Hog and Pig Farming · OSHA's record · Phone and website on Google Maps

Incident on Feb 19, 2019: Employee experiences multiple symptoms when exposed to carbo

At 4:45 p.m. on February 19, 2019, an employee was working for a land grant university. He arrived at work, reviewed the list of tasks to be done, and chose to power wash a swine nursery. The swine nursery comprised four 1.5-meter by 3-meter (5-foot by 10-foot) pens that needed to be power washed. The swine nursery was not equipped with electrical components, so a gasoline-powered power washer had to be used. The water hook up was inside the nursery area. Two hose lengths were attached. The hose lengths were not long enough to set the machine fully outside, so the power washer was placed with a wheel propping open the outside door. The employee began power washing the swine nursery. After approximately an hour of work, he started feeling symptoms: headache, blurred vision, weakness, and dizziness. He turned everything off and noticed the the outside door was partially closed (cracked open) from the wind. The employee walked to the pavilion, falling down from dizziness a few times. He was suffering from elevated carboxyhemoglobin blood levels. He was hospitalized. Later, he was transferred to a different hospital to receive hyperbaric chamber treatments. Following the employee's exposure, it was determined that the employee had been exposed to a concentration of 150.4 parts carbon monoxide per million parts of air for an 8-hour time-weighted average (TWA). The exposure concentration was determined by the employee's carboxyhemoglobin (%COHb) medical blood gas measurement.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$12,934$7,700May 20, 2019Final
13 older inspections

Inspection 342645389 OPENED SEP 19, 2017Closed

Referral · Partial · Safety · State government · 13,570 employees at the site · Closed Nov 13, 2017

3810 Beardshear Hall, Ames, IA 50011 · Colleges, Universities, and Professional Schools · OSHA's record · Phone and website on Google Maps

Incident on Sep 11, 2017: Employee falls from stairwell landing and sustains fractures

At 11:45 a.m. on September 11, 2017, an employee was working for a public university. He was standing on a stairwell landing. He fell approximately 5.5 meters (18 feet) from the stairwell landing to the floor below. He sustained fractured ribs, a fractured shoulder blade, a fracture to the tip of one vertebra, and the laceration of his head. He was hospitalized.

No citations from this inspection.

Inspection 317572394 OPENED FEB 6, 2014Closed

Complaint · Partial · Safety · State government · 8,609 employees at the site · Closed Feb 13, 2014

Various Locations On Campus, Ames, IA 50011 · Colleges, Universities, and Professional Schools · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 115081846 OPENED JUL 31, 1996Closed

Complaint · Partial · Safety · 150 employees at the site · Closed Oct 10, 1996

Beardshear Hall, Campus Isu, Ames, IA 50011 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(3) · General requirements
Other-than-serious$2,750$1,500Aug 21, 1996Closed

Inspection 115072118 OPENED OCT 28, 1994Closed

Complaint · Partial · Health · State government · 4 employees at the site · Closed Nov 28, 1994

R.r. 1, Horticulture Station, Ames, IA 50010 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1200006
Other-than-serious$0$0Nov 7, 1994Closed
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 7, 1994Closed
Citation 1, item 3
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Nov 7, 1994Closed

Inspection 115053134 OPENED OCT 14, 1992Closed

Complaint · Complete · Safety · State government · 85 employees at the site · Closed Jun 7, 1993

Power Plant, Ames, IA 50010 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(d)(2) · Exit route design
Serious$5,000$1,750Nov 10, 1992Closed
Citation 1, item 3
29 CFR 1910.37(k)(2) · Exit routes
Serious$5,000$1,750Nov 10, 1992Closed
Citation 1, item 4
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$5,000$3,500Nov 10, 1992Closed
Citation 2, item 1
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$25,000$3,000Nov 10, 1992Closed

Inspection 115047573 OPENED JAN 23, 1992Closed

Complaint · Partial · Safety · State government · 3 employees at the site · Closed May 4, 1992

2854 Arbor Street, Work Shops, Ames, IA 50010 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes
Serious$2,000$900Feb 24, 1992Closed
Citation 1, item 2
29 CFR 1910.24(f) · Fixed industrial stairs
Serious$2,000$900Feb 24, 1992Closed
Citation 1, item 3
29 CFR 1910.25(d)(1)(x) · Portable wood ladders
Serious$2,000$900Feb 24, 1992Closed
Citation 1, item 4
29 CFR 1910.213(d)(1) · Woodworking machinery
Serious$5,000$2,000Feb 24, 1992Closed
Citation 1, item 5
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$5,000$2,000Feb 24, 1992Closed
Citation 1, item 6
29 CFR 1910.252(c)(2)(1) · Welding fire safety
Other-than-serious$2,000$500Feb 24, 1992Closed
Citation 2, item 1
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Repeat$12,500$5,000Feb 24, 1992Closed
Citation 2, item 2
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Repeat$25,000$12,000Feb 24, 1992Closed
Citation 3, item 1
29 CFR 30001
Other-than-serious$1,000$800Feb 24, 1992Closed
Citation 3, item 2
29 CFR 1200003 4
Other-than-serious$0$0Feb 24, 1992Closed

Inspection 104255831 OPENED JUN 5, 1991Closed

Complaint · Partial · Health · State government · 6,000 employees at the site · Closed Nov 8, 1991

100 University Village, Department Of Residence, Ames, IA 50010 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$210$210Sep 23, 1991Closed
Citation 1, item 2
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$210$210Sep 23, 1991Closed
Citation 1, item 3a
29 CFR 1910.1048(i)(2) · Formaldehyde
Serious$420$420Sep 23, 1991Closed
Citation 1, item 3b
29 CFR 1910.1048(i)(3) · Formaldehyde
Serious$0$0Sep 23, 1991Closed
Citation 1, item 4
29 CFR 1910.1450(e)(1) · Occupational exposure to hazardous chemicals in laboratories
Other-than-serious$490$0Sep 23, 1991Closed
Citation 2, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$0$0Sep 23, 1991Closed
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Sep 23, 1991Closed

Inspection 104255724 OPENED JUL 5, 1990Closed

Complaint · Partial · Health · State government · 90 employees at the site · Closed Dec 7, 1990

2419 Friley Hall, Uda Complex Office, Ames, IA 50010 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.24(h) · Fixed industrial stairs
Serious$420$210Sep 19, 1990Closed
Citation 1, item 2
29 CFR 1910.24(i) · Fixed industrial stairs
Serious$420$210Sep 19, 1990Closed
Citation 1, item 5a
29 CFR 1910.178(g)(2) · Forklifts and other powered industrial trucks
Serious$490$200Sep 19, 1990Closed
Citation 1, item 5b
29 CFR 1910.178(g)(2) · Forklifts and other powered industrial trucks
Serious$0$0Sep 19, 1990Closed
Citation 2, item 3
29 CFR 1910.107(g)(1) · Spray painting and finishing
Other-than-serious$0$0Sep 19, 1990Closed
Citation 2, item 4a
29 CFR 1910.134(b)(2) · Respiratory protection
Other-than-serious$210$0Sep 19, 1990Closed
Citation 2, item 4b
29 CFR 1910.134(b)(3) · Respiratory protection
Other-than-serious$0$0Sep 19, 1990Closed
Citation 2, item 4c
29 CFR 1910.134(b)(7) · Respiratory protection
Other-than-serious$0$0Sep 19, 1990Closed
Citation 2, item 4d
29 CFR 1910.134(b)(8) · Respiratory protection
Other-than-serious$0$0Sep 19, 1990Closed
Citation 2, item 4e
29 CFR 1910.134(b)(10) · Respiratory protection
Other-than-serious$0$0Sep 19, 1990Closed
Citation 2, item 4f
29 CFR 1910.134(b)(11) · Respiratory protection
Other-than-serious$0$0Sep 19, 1990Closed
Citation 2, item 4g
29 CFR 1910.134(e)(2) · Respiratory protection
Other-than-serious$0$0Sep 19, 1990Closed
Citation 2, item 4h
29 CFR 1910.134(e)(4) · Respiratory protection
Other-than-serious$0$0Sep 19, 1990Closed
Citation 2, item 4i
29 CFR 1910.134(e)(5) · Respiratory protection
Other-than-serious$0$0Sep 19, 1990Closed
Citation 2, item 4j
29 CFR 1910.134(e)(5) · Respiratory protection
Other-than-serious$0$0Sep 19, 1990Closed
Citation 2, item 4k
29 CFR 1910.134(f)(3) · Respiratory protection
Other-than-serious$0$0Sep 19, 1990Closed
Citation 2, item 5
29 CFR 1200004 1
Other-than-serious$210$0Sep 19, 1990Closed
Citation 2, item 6
29 CFR 1200006
Other-than-serious$210$100Sep 19, 1990Closed

Inspection 104247481 OPENED MAR 6, 1990Closed

Complaint · Partial · Safety · State government · 40 employees at the site · Closed May 31, 1990

Physical Plant, Ames, IA 50010 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.37(q)(5) · Exit routes
Serious$350$300Mar 28, 1990Closed
Citation 1, item 3
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$350$300Mar 28, 1990Closed
Citation 1, item 5
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$280$200Mar 28, 1990Closed
Citation 1, item 6
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$350$300Mar 28, 1990Closed

Inspection 104249834 OPENED FEB 22, 1990Closed

Complaint · Partial · Health · State government · 80 employees at the site · Closed Mar 22, 1993

Physical Plant, Ames, IA 50010 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 880004
Serious$640$300Jun 18, 1990Final
Citation 1, item 3
29 CFR 880004
Serious$640$300Jun 18, 1990Final
Citation 1, item 5e
29 CFR 1910.134(e)(3)(iii) · Respiratory protection
Serious$0$500Jun 18, 1990Final
Citation 1, item 5f
29 CFR 1910.134(e)(4) · Respiratory protection
Serious$0$0Jun 18, 1990Final
Citation 1, item 5g
29 CFR 1910.134(e)(5) · Respiratory protection
Other-than-serious$0$0Jun 18, 1990Final
Citation 1, item 5h
29 CFR 1910.134(e)(5)(i) · Respiratory protection
Other-than-serious$0$0Jun 18, 1990Final
Citation 1, item 5i
29 CFR 1910.134(f)(2)(iii) · Respiratory protection
Other-than-serious$0$0Jun 18, 1990Final
Citation 1, item 5j
29 CFR 1910.134(f)(3) · Respiratory protection
Other-than-serious$0$0Jun 18, 1990Final
Citation 1, item 9a
29 CFR 1910.1000(c) · Air contaminants
Other-than-serious$810$0Jun 18, 1990Final
Citation 1, item 9b
29 CFR 1910.1000(e) · Air contaminants
Other-than-serious$0$0Jun 18, 1990Final
Citation 1, item 10
29 CFR 1200006
Other-than-serious$810$0Jun 18, 1990Final
Citation 2, item 1
29 CFR 40005 1
Other-than-serious$200$0Jun 18, 1990Final

Inspection 104195839 OPENED OCT 24, 1989Closed

Complaint · Partial · Health · State government · 8,000 employees at the site · Closed Jan 25, 1990

Dairy Industry Building, Ames, IA 50011 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104228366 OPENED FEB 15, 1989Closed

Complaint · Partial · Safety · State government · 6 employees at the site · Closed May 3, 1989

51 Dairy Industries Bldg, Dept. Of Food Technology, Ames, IA 50011 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1200005 1
Other-than-serious$0$0Mar 10, 1989Closed
Citation 2, item 2
29 CFR 1200006
Other-than-serious$0$0Mar 10, 1989Closed

Inspection 104208434 OPENED DEC 17, 1987Closed

Referral · Partial · Health · State government · 8,000 employees at the site · Closed Feb 10, 1988

100 University Village, Department Of Residence, Ames, IA 50010 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1200003 1
Other-than-serious$0$0Jan 4, 1988Closed
Citation 1, item 2
29 CFR 1200006
Other-than-serious$0$0Jan 4, 1988Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Ames site logged 206 recordable injuries or illnesses among about 17,075 workers: 1.8 per 100 full-time workers, against a median of 1.2 for its industry. Those cases cost 954 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
ISU - University Wide
Ames · 2017
17,075 206331.81.2
ISU - On Campus
Ames · 2017
16,257 175281.71.2
Dairy Farm
Ames · 2017
64 7219.71.2
Boone County Extension
Boone · 2016
9,558 000.01.2
Extension 4-H Youth Building
Ames · 2016
65 000.01.2
VenuWorks of Ames, LLC / Iowa State Center
Ames · 2016
152 213.43.2

Included with any plan: 2 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(c)

(c) Table Z-3. An employee's exposure to any substance listed in Table Z-3, in any 8-hour work shift of a 40-hour work week, shall not exceed the 8-hour time weighted average limit given for that substance in the table.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1048 · Formaldehyde

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.1450 · Occupational exposure to hazardous chemicals in laboratories

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

OSH Act Section 5 · General Duty Clause

Other colleges, universities, and professional schools employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.