OSHA SearchOSHA records by employer

Lexington Metal Fabricators, Inc.: OSHA inspections and violations

Linwood, North Carolina · Plate Work Manufacturing · NAICS 332313

11inspections
65citation items
$9,900current penalties
Feb 26, 2025last inspection

OSHA has inspected Lexington Metal Fabricators, Inc. 11 times in North Carolina since 1997.

The latest one began on Feb 26, 2025 as a planned inspection, in Linwood.

Those inspections ended with 65 citation items: 27 serious and 38 other-than-serious.

Penalties were first proposed at $13,425 and now stand at $9,900, 26% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 6 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Lexington Metal Fabricators, Inc. averages $3,562 (2 cited inspections).

Lexington Metal Fabricators, Inc. also files yearly injury logs with OSHA, summarized below.

Lexington Metal Fabricators, Inc.: OSHA citation items per year, 1997 to 2025
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Lexington Metal Fabricators, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348070152 OPENED FEB 26, 2025Closed

Planned · Complete · Health · 29 employees at the site · Closed Jul 1, 2025

300 Lexington Metal Dr., Linwood, NC 27299 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$750$750May 28, 2025Final
Citation 1, item 2a
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$2,000$2,000May 28, 2025Final
Citation 1, item 2b
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0May 28, 2025Final
Citation 2, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0May 28, 2025Final
Citation 2, item 2
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Other-than-serious$0$0May 28, 2025Final
Citation 2, item 3
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0May 28, 2025Final

Inspection 344539382 OPENED JAN 6, 2020Closed

Follow-up · Partial · Safety · 26 employees at the site · Closed Jan 8, 2020

300 Lexington Metal Dr, Linwood, NC 27299 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344257183 OPENED AUG 21, 2019Closed

Planned · Complete · Safety · 26 employees at the site · Closed Nov 20, 2019

300 Lexington Metal Dr, Linwood, NC 27299 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(i)(b) · Lockout/tagout
Serious$1,500$1,050Oct 4, 2019Final
Citation 1, item 2a
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$2,800$1,960Oct 4, 2019Final
Citation 1, item 2b
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$0$0Oct 4, 2019Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,500$1,050Oct 4, 2019Final
Citation 1, item 4
29 CFR 1910.212(b) · Machine guarding
Serious$450$315Oct 4, 2019Final
Citation 2, item 1
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Oct 4, 2019Final
Citation 2, item 2b
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Oct 4, 2019Final
Citation 2, item 3
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Other-than-serious$0$0Oct 4, 2019Final
Citation 2, item 4
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 4, 2019Final
Citation 2, item 5
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 4, 2019Final
Citation 2, item 6
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Oct 4, 2019Final
Citation 2, item 7
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Oct 4, 2019Final
Citation 2, item 8
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Oct 4, 2019Final
Citation 2, item 9
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$0Oct 4, 2019Final

Inspection 317940039 OPENED NOV 18, 2014Closed

Planned · Complete · Health · 35 employees at the site · Closed Feb 3, 2015

300 Lexington Metal Dr, Linwood, NC 27299 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$750$750Jan 8, 2015Closed
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$225$225Jan 8, 2015Closed
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Jan 8, 2015Closed
Citation 2, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jan 8, 2015Closed
Citation 2, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jan 8, 2015Closed
Citation 2, item 4
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jan 8, 2015Closed

Inspection 316028307 OPENED SEP 29, 2011Closed

Follow-up · Partial · Health · 24 employees at the site · Closed Nov 18, 2011

110 Belmont Road, Linwood, NC 27299 · Other Metal Valve and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315609552 OPENED MAY 13, 2011Closed

Complaint · Partial · Health · 24 employees at the site · Closed Aug 2, 2011

110 Belmont Road, Linwood, NC 27299 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$150$150Jul 13, 2011Closed
Citation 1, item 1b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Jul 13, 2011Closed

Inspection 312196876 OPENED DEC 18, 2008Closed

Planned · Complete · Health · 30 employees at the site · Closed Jan 21, 2009

110 Belmont Blvd. Ext., Linwood, NC 27299 · Other Metal Container Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(h)(4) · Overhead and gantry cranes
Other-than-serious$0$0Jan 7, 2009Closed
Citation 1, item 2
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 7, 2009Closed

Inspection 308553742 OPENED MAY 10, 2005Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Jun 22, 2005

110 Belmont Road, Linwood, NC 27299 · Industrial Truck, Tractor, Trailer, and Stacker Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7F010102
Other-than-serious$0$0May 24, 2005Closed
3 older inspections

Inspection 301933248 OPENED JUL 23, 1998Closed

Complaint · Partial · Safety · 22 employees at the site · Closed Jan 5, 2011

110 Belmont Blvd., Linwood, NC 27299 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7F0102
Other-than-serious$0$0Aug 3, 1998Closed

Inspection 301933263 OPENED JUL 23, 1998Closed

Complaint · Partial · Health · 22 employees at the site · Closed Jan 5, 2011

110 Belmont Blvd., Linwood, NC 27299 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300224086 OPENED SEP 4, 1997Closed

Planned · Complete · Safety · 10 employees at the site · Closed Jan 5, 2011

110 Belmont Blvd., Linwood, NC 27299 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(2)(ivd) · Flammable liquids
Serious$700$350Sep 23, 1997Closed
Citation 1, item 1b
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$0$0Sep 23, 1997Closed
Citation 1, item 1c
29 CFR 1910.107(e)(9) · Spray painting and finishing
Serious$0$0Sep 23, 1997Closed
Citation 1, item 2a
29 CFR 1910.178(k)(1) · Forklifts and other powered industrial trucks
Serious$300$150Sep 23, 1997Closed
Citation 1, item 2b
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$0$0Sep 23, 1997Closed
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$300$150Sep 23, 1997Closed
Citation 1, item 4a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$300$150Sep 23, 1997Closed
Citation 1, item 4b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Sep 23, 1997Closed
Citation 1, item 5a
29 CFR 1910.252(b)(2)(ia) · Welding fire safety
Serious$300$150Sep 23, 1997Closed
Citation 1, item 5b
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$0$0Sep 23, 1997Closed
Citation 1, item 6a
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$700$350Sep 23, 1997Closed
Citation 1, item 6b
29 CFR 1910.110(f)(2)(ii) · Storage and handling of liquefied petroleum gases
Serious$0$0Sep 23, 1997Closed
Citation 1, item 7a
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$700$350Sep 23, 1997Closed
Citation 1, item 7b
29 CFR 1910.94(c)(2) · Ventilation
Serious$0$0Sep 23, 1997Closed
Citation 1, item 7c
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$0$0Sep 23, 1997Closed
Citation 2, item 1
29 CFR 7F0102
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 2
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 3
29 CFR 1910.134(b)(1) · Respiratory protection
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 4
29 CFR 1910.136(a) · Foot protection
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 5
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 6
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 7
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 8
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 9
29 CFR 1910.253(e)(3)(iic)(2) · Gas welding and cutting
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 10
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 11
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 12
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 13
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 14
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 15a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 15b
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 15c
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Sep 23, 1997Closed
Citation 2, item 15d
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Sep 23, 1997Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Linwood site logged 0 recordable injuries or illnesses among about 19 workers: 0.0 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Lexington Metal Fabricators, Inc
Linwood · 2025
19 000.03.6

Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ivd)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.136 · Foot protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.94 · Ventilation

Other plate work manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.