Inspection 349050468 OPENED JUL 14, 2026Open
3301 Castlewood Road, Richmond, VA 23234 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
OSHA has inspected Miller Manufacturing Company, Inc. 7 times in Virginia since 1982.
The latest one began on Jul 14, 2026 after a complaint, in Richmond; the case is still open.
Those inspections ended with 46 citation items: 11 serious and 35 other-than-serious.
Penalties were first proposed at $30,274 and now stand at $29,336, 3% lower after settlements or reviews.
Electrical wiring methods comes up most often in these citations: 6 items under 1910.305.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Miller Manufacturing Company, Inc. averages $9,246 (3 cited inspections).
Miller Manufacturing Company, Inc. also files yearly injury logs with OSHA, summarized below.
Virginia · latest 90 days of OSHA records
253employers cited
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch Miller Manufacturing Company, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company3301 Castlewood Road, Richmond, VA 23234 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
3301 Castlewood Road, Richmond, VA 23234 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 16VAC25-60-120 |
Serious | $13,434 | $13,434 | Jul 28, 2022 | Final |
| Citation 1, item 1b 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $0 | $0 | Jul 28, 2022 | Final |
3301 Castlewood Road, Richmond, VA 23234 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Serious | $2,540 | $1,778 | Mar 27, 2019 | Final |
| Citation 2, item 1 29 CFR 1910.134(h)(3)(ii)(b) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 27, 2019 | Final |
| Citation 2, item 2 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Mar 27, 2019 | Final |
| Citation 2, item 3 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Other-than-serious | $585 | $410 | Mar 27, 2019 | Final |
3301 Castlewood Road, Richmond, VA 23234 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Aug 15, 2018: Employee amputates finger when caught in press die
At 3:15 p.m. on August 15, 2018, an employee was operating a 40 Ton Rousselle No 4 Mechanical Power Press punching out metal clips from a reel of approximately 17 gauge steel. The employee reached around with his right hand to remove a jam that developed while punching out some clips and stepped on the foot control pedal, engaging the press. The employee caught his pinky in the die and amputated his finger. The employee was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Serious | $2,875 | $2,875 | Nov 14, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.217(b)(7)(ii) · Mechanical power presses |
Serious | $2,875 | $2,875 | Nov 14, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.217(c)(1)(i) · Mechanical power presses |
Serious | $6,365 | $6,365 | Nov 14, 2018 | Final |
2310 Deepwater Terminal Road, Richmond, VA 23224 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2310 Deepwater Terminal Road, Richmond, VA 23224 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $320 | $320 | Apr 13, 1989 | Closed |
| Citation 1, item 2 29 CFR 1910.213(h)(1) · Woodworking machinery |
Serious | $400 | $400 | Apr 13, 1989 | Closed |
| Citation 1, item 3a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $320 | $320 | Apr 13, 1989 | Closed |
| Citation 1, item 3b 29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 1, item 4 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Serious | $320 | $320 | Apr 13, 1989 | Closed |
| Citation 2, item 1a 29 CFR ARM001101 A |
Other-than-serious | $80 | $80 | Apr 13, 1989 | Closed |
| Citation 2, item 1b 29 CFR ARM001101 A |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 2 29 CFR ARM001101 F |
Other-than-serious | $160 | $160 | Apr 13, 1989 | Closed |
| Citation 2, item 3 29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 4 29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 5 29 CFR 1910.24(b) · Fixed industrial stairs |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 6 29 CFR 1910.37(q)(1) · Exit routes |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 7 29 CFR 1910.37(q)(6) · Exit routes |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 8 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 9 29 CFR 1910.141(a)(3)(i) · Sanitation |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 10 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 11 29 CFR 1910.157(c)(4) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 12 29 CFR 1910.157(c)(4) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 13 29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 14 29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 15 29 CFR 1910.212(a)(1) · Machine guarding |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 16 29 CFR 1910.213(b)(5) · Woodworking machinery |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 17 29 CFR 1910.213(i)(1) · Woodworking machinery |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 18 29 CFR 1910.213(p)(4) · Woodworking machinery |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 19 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 20 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 21 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 22 29 CFR 1910.305(a)(1)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 23 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 24a 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 24b 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 25 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 26 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 27 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 28 29 CFR 1910.1200(f)(4)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 29 29 CFR 1910.1200(g)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
| Citation 2, item 30 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 13, 1989 | Closed |
7th And Stockton Streets, Richmond, VA 23224 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Richmond site logged 2 recordable injuries or illnesses among about 34 workers: 5.7 per 100 full-time workers, against a median of 3.3 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Miller Manufacturing Richmond · 2025 | 34 | 2 | 0 | 5.7 | 3.3 |
Included with any plan: 5 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(g)(2)
(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.1200(f)(4)(ii)
(ii) The label may be transmitted with the initial shipment itself, or with the safety data sheet that is to be provided prior to or at the time of the first shipment; and,
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.