Showbest Fixture Corp: OSHA inspections and violations
Henrico, Virginia · Showcase, Partition, Shelving, and Locker Manufacturing · NAICS 337215
9inspections
43citation items
$23,483current penalties
Jul 3, 2025last inspection
Showbest Fixture Corp has 9 OSHA inspections on record in Virginia, the first in 1994.
OSHA's last visit started on Jul 3, 2025 on a referral, in Henrico.
Across those inspections OSHA issued 43 citation items: 28 serious and 15 other-than-serious.
OSHA proposed $32,600 in penalties. After settlements and reviews the total is $23,483, down 28%.
Most often, OSHA cited 1910.134, respiratory protection (7 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Showbest Fixture Corp averages $6,435 over 3 cited inspections in that time.
Showbest Fixture Corp also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Virginia · latest 90 days of OSHA records
246employers cited
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Richmond site logged 2 recordable injuries or illnesses among about 98 workers: 1.8 per 100 full-time workers, against a median of 4.6 for its industry. Those cases cost 100 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Showbest Fixture Corp.
Richmond · 2025
98
2
1
1.8
4.6
Richmond
Henrico · 2021
85
0
0
0.0
4.6
Blackstone site
Blackstone · 2020
26
0
0
0.0
4.6
Included with any plan: 4 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(9)
(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.