OSHA SearchOSHA records by employer

Northwest Foam Products, Inc: OSHA inspections and violations

Twin Falls, Idaho · Urethane and Other Foam Product (except Polystyrene) Manufacturing · NAICS 326150

1inspections
15citation items
$7,605current penalties
Feb 9, 2017last inspection

Northwest Foam Products, Inc has one OSHA inspection on record in Idaho.

OSHA opened it on Feb 9, 2017 as a planned inspection, in Twin Falls.

From that inspection OSHA issued 15 citation items: 14 serious and 1 other-than-serious.

OSHA proposed $15,210 in penalties. After settlements and reviews the total is $7,605, down 50%.

Most often, OSHA cited 1910.305, electrical wiring methods (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Northwest Foam Products, Inc averages $7,605 over 1 cited inspection in that time.

Northwest Foam Products, Inc: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

55employers cited

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch Northwest Foam Products, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342092798 OPENED FEB 9, 2017Closed

Planned · Partial · Safety · 19 employees at the site · Closed May 30, 2017

642 Grange Lane, Twin Falls, ID 83301 · Urethane and Other Foam Product (except Polystyrene) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
OSH Act Section 5(a)(1) · General Duty Clause
Serious$4,346$2,173May 10, 2017Final
Citation 1, item 1b
29 CFR 1910.178(l)(2)(ii) · Forklifts and other powered industrial trucks
Serious$0$0May 10, 2017Final
Citation 1, item 2a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$2,897$1,448May 10, 2017Final
Citation 1, item 2b
29 CFR 1910.147(f)(2)(i) · Lockout/tagout
Serious$0$0May 10, 2017Final
Citation 1, item 3a
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$2,897$1,448May 10, 2017Final
Citation 1, item 3b
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0May 10, 2017Final
Citation 1, item 3c
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0May 10, 2017Final
Citation 1, item 4a
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$2,897$1,448May 10, 2017Final
Citation 1, item 4b
29 CFR 1910.303(b)(7) · Electrical equipment, general requirements
Serious$0$0May 10, 2017Final
Citation 1, item 4c
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0May 10, 2017Final
Citation 1, item 4d
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0May 10, 2017Final
Citation 1, item 5a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,173$1,086May 10, 2017Final
Citation 1, item 5b
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0May 10, 2017Final
Citation 1, item 5c
29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods
Serious$0$0May 10, 2017Final
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0May 10, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.147(f)(2)(i)

(2) Check the work area to ensure that all employees have been safely positioned or removed from the area.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

OSH Act Section 5 · General Duty Clause

Other urethane and other foam product (except polystyrene) manufacturing employers in Idaho

Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.