Inspection 348165036 OPENED MAR 24, 2025Closed
416 Ne Highway 101, Lincoln City, OR 97367 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Pacificorp 117 times in Oregon since 1986.
The latest one began on Mar 24, 2025, in Lincoln City.
Those inspections ended with 123 citation items: 58 serious, 3 repeat and 62 other-than-serious.
Penalties were first proposed at $24,395 and now stand at $24,215, 1% lower after settlements or reviews.
Electric power generation, transmission, and distribution comes up most often in these citations: 11 items under 1910.269.
How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Pacificorp averages $0 (2 cited inspections).
Pacificorp also files yearly injury logs with OSHA, summarized below.
Want to know if OSHA cites Pacificorp again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company416 Ne Highway 101, Lincoln City, OR 97367 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
416 Ne Highway 101, Lincoln City, OR 97367 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
830 Old Salem Rd Ne, Albany, OR 97321 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1111 Mill Creek Dr, Prospect, OR 97536 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1200(f)(6)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Feb 10, 2020 | Final |
| Citation 1, item 2 29 CFR OAR 437-001-0765(7)-3 |
Other-than-serious | $0 | $0 | Feb 10, 2020 | Final |
925 S Grape St, Medford, OR 97501 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1200(f)(6) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 25, 2019 | Final |
4351 Westgate St, Pendleton, OR 97801 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
91842 George Hill Rd, Astoria, OR 97103 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
830 Old Salem Rd Ne, Albany, OR 97321 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
497 Se Cleveland Ave, Bend, OR 97701 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
317 2nd St, Independence, OR 97351 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
830 Old Salem Rd Ne, Albany, OR 97321 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1440 Anthony St, Cottage Grove, OR 97424 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
Incident on Feb 10, 2014: Electric shock - direct contact with energized parts
On February 10, 2014, an employee was working as a journeyman line worker for th e electric utility Pacificorp in Cottage Grove, Oregon. He was part of a crew re pairing damaged powerlines. He came into contact with a guy that had become ener gized. He sustained an electric shock.
No citations from this inspection.
416 Ne Highway 101, Lincoln City, OR 97367 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
11716 Ne Sumner St, Portland, OR 97220 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
328 Ne Webster, Bend, OR 97701 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4025 Old Highway 99s, Roseburg, OR 97471 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(b)(1) · General requirements |
Other-than-serious | $0 | $0 | Nov 3, 2011 | Closed |
| Citation 1, item 2 | Other-than-serious | $0 | $0 | Nov 3, 2011 | Closed |
310 Ne Boston St, Roseburg, OR 97470 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
102 N E St, Lakeview, OR 97630 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
215 N G St, Lakeview, OR 97630 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1339 S 3rd St, Lakeview, OR 97630 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $100 | $100 | Apr 12, 2011 | Closed |
| Citation 2, item 2 | Other-than-serious | $0 | $0 | Apr 12, 2011 | Closed |
2000 W 2nd, The Dalles, OR 97058 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
925 S Grape St, Medford, OR 97501 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.213(h)(4) · Woodworking machinery |
Serious | $105 | $105 | Jan 7, 2011 | Closed |
284 E Water, Stayton, OR 97383 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
207 Sw 6th St, Corvallis, OR 97330 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
301 Ne 6th St, Grants Pass, OR 97526 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
914 S 2nd St, Lebanon, OR 97355 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
75 S 5th St, Cottage Grove, OR 97424 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
325 N Adams St, Coquille, OR 97423 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2nd & Revere, Bend, OR 97701 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.67(c)(2)(iv) · Vehicle-mounted elevating and rotating work platforms |
Serious | $175 | $175 | May 21, 2010 | Closed |
| Citation 1, item 2 | Serious | $325 | $325 | May 21, 2010 | Closed |
| Citation 1, item 3 29 CFR 1910.269(g)(2)(ix) · Electric power generation, transmission, and distribution |
Serious | $175 | $175 | May 21, 2010 | Closed |
| Citation 1, item 4 29 CFR 1910.269(g)(2)(vic) · Electric power generation, transmission, and distribution |
Serious | $175 | $175 | May 21, 2010 | Closed |
1290 Tucker Rd, Hood River, OR 97031 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
615 Holley St, Junction City, OR 97448 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7200 Toketee School Rd, Idleyld Park, OR 97447 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
201 Sw Columbia, Bend, OR 97701 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1343 Monmouth St Ste A, Independence, OR 97351 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
830 Old Salem Rd Ne, Albany, OR 97321 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(d)(1) · Guarding floor and wall openings and holes |
Serious | $390 | $390 | Dec 17, 2009 | Closed |
| Citation 1, item 2 29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes |
Serious | $390 | $390 | Dec 17, 2009 | Closed |
| Citation 1, item 3 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $390 | $390 | Dec 17, 2009 | Closed |
411 5th St, Madras, OR 97741 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4235 Westgate Ave, Pendleton, OR 97801 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
Incident on Jul 14, 2009: Employee is injured when utility pole falls from truck
At approximately 9:00 a.m. on July 14, 2009, Employee #1 was loading utility pol es onto a trailer. He loaded the fourth pole and was removing the rigging chain, when the pole fell off the trailer and struck and killed him.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.269(a)(2)(i) · Electric power generation, transmission, and distribution |
Serious | $2,500 | $2,500 | Jan 6, 2010 | Final |
| Citation 1, item 1b | Serious | $0 | $0 | Jan 6, 2010 | Final |
| Citation 1, item 1c 29 CFR 1910.269(c) · Electric power generation, transmission, and distribution |
Serious | $0 | $0 | Jan 6, 2010 | Final |
1950 Mallard Ln, Klamath Falls, OR 97601 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
328 Ne Webster Ave, Bend, OR 97701 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Oct 12, 2009 | Closed |
825 Ne Multnomah Ste 1560, Portland, OR 97232 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
216 W Main St, Talent, OR 97502 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1900 Sw 4th Ave 2nd Fl, Portland, OR 97201 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1420 Williams Hwy, Grants Pass, OR 97526 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
925 S Grape St, Medford, OR 97501 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
925 S Grape St, Medford, OR 97501 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $105 | $105 | Jul 12, 2007 | Closed |
| Citation 2, item 2 29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Jul 12, 2007 | Closed |
1900 Sw 4th Ave 2nd Fl, Portland, OR 97201 · Hydroelectric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1033 Ne 6th Ave, Portland, OR 97208 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1290 Tucker Road, Hood River, OR 97031 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1950 Mallard Ln, Klamath Falls, OR 97601 · Fossil Fuel Electric Power Generation · OSHA's record · Phone and website on Google Maps
Incident on Jun 23, 2004: Electric shock - direct contact with energized parts
An electric utility employee was assisting in testing capacitor-coupled transfor mers in a 500-kilovolt substation. When he disconnected the test leads from the Doble test set, the employee received an electric shock from an apparent static discharge. The shock burned both of his hands and his left leg. He was hospitali zed for his injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Other-than-serious | $500 | $500 | Sep 7, 2004 | Closed |
7544 Ne 33rd Dr, Portland, OR 97211 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $540 | $540 | Jul 22, 2004 | Closed |
| Citation 1, item 2 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $360 | $360 | Jul 22, 2004 | Closed |
| Citation 2, item 3 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jul 22, 2004 | Closed |
| Citation 2, item 4 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jul 22, 2004 | Closed |
825 Ne Multnomah Ste 1560, Portland, OR 97232 · Hydroelectric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Main St, Sweet Home, OR 97386 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1111 Mill Creek Dr, Prospect, OR 97536 · OSHA's record · Phone and website on Google Maps
Incident on Oct 2, 2002: Employee injured when crane tipped over
On October 2, 2002, Employee #1, of Oldham Crane Services Inc., was operating a 50-ton Grove crane to drive pilings on the construction project. The crane had b een set up and one piling driven. Employee #1 rotated the crane boom to pick up the next piling. As the piling was being lifted, there was a sudden movement of the entire crane and it began tipping over on the side on which the lift was bei ng made. As the crane tipped over, Employee #1 jumped from the crane cab, approx imately 10 ft above the access road that the crane had been set up on. The crane boom contacted a 2,400-volt overhead power line, trapping it under the boom as the boom fell to its side. The devices protecting the power line deenergized it when the line contacted the ground. After the electric utility confirmed the pow er line was deenergized, crew members responded to assist Employee #1. He was tr ansported to a local hospital, where he was hospitalized for hip and pelvic inju ries.
No citations from this inspection.
1950 Mallard Ln, Klamath Falls, OR 97601 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $210 | $210 | Nov 8, 2002 | Closed |
| Citation 1, item 2 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $300 | $300 | Nov 8, 2002 | Closed |
| Citation 1, item 3 29 CFR 1910.242(b) · Hand and power tools |
Serious | $210 | $210 | Nov 8, 2002 | Closed |
| Citation 2, item 4 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Nov 8, 2002 | Closed |
| Citation 2, item 5a 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Nov 8, 2002 | Closed |
| Citation 2, item 5b 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Nov 8, 2002 | Closed |
| Citation 2, item 6 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Nov 8, 2002 | Closed |
1111 Mill Creek Dr, Prospect, OR 97536 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
583 Se Jefferson St, Dallas, OR 97338 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
40th And Ne Tillamook, Portland, OR 97211 · OSHA's record · Phone and website on Google Maps
Incident on Apr 12, 2002: Electric shock - direct contact with overhead line
A journeyman power line worker was on a utility pole, installing jumpers connect ing power line conductors together. As he was changing his position on the pole, his back contacted a 7200-volt overhead power line. He received an electric sho ck and was hospitalized for his injuries.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.950(c)(1) · Electric Power Transmission and Distribution: general |
Serious | $500 | $500 | Jun 25, 2002 | Closed |
| Citation 1, item 1b 29 CFR 7030145 |
Serious | $0 | $0 | Jun 25, 2002 | Closed |
4351 Westgate Street, Pendleton, OR 97801 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
925 S Grape St, Medford, OR 97501 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.29(f)(4)(i) · Manually propelled mobile ladder stands and scaffolds (towers) |
Other-than-serious | $0 | $0 | Apr 17, 2002 | Closed |
1420 Williams Hwy, Grants Pass, OR 97526 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 7, 2002 | Closed |
135 W Lockhart, Coos Bay, OR 97420 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(g)(6) · Noise |
Other-than-serious | $0 | $0 | Oct 8, 2001 | Closed |
63140 Britta St, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
825 Ne Multnomah Ste 1560, Portland, OR 97232 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7200 Toketee School Rd, Idleyld Park, OR 97447 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.243(c)(3) · Guarding of portable powered tools |
Serious | $210 | $210 | May 24, 2001 | Closed |
| Citation 1, item 2 29 CFR 1910.242(b) · Hand and power tools |
Serious | $300 | $300 | May 24, 2001 | Closed |
| Citation 2, item 3 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | May 24, 2001 | Closed |
1908 Barnett Rd, Medford, OR 97504 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms |
Serious | $1,050 | $1,050 | Jun 8, 2001 | Closed |
9th & Reed Market Rd, Bend, OR 97702 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.201(a)(4) · Signaling |
Serious | $350 | $350 | Jan 18, 2000 | Closed |
| Citation 1, item 2 | Serious | $350 | $350 | Jan 18, 2000 | Closed |
1420 Williams Hwy, Grants Pass, OR 97526 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
935 N Crest, Central Point, OR 97502 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Virginia St And Marion St, North Bend, OR 97459 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2045 E Main St, Ashland, OR 97520 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $210 | $210 | Sep 20, 1999 | Closed |
Virginia St And Marion St, North Bend, OR 97459 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.601(b)(8) · Motor vehicles |
Serious | $1,250 | $1,250 | Jul 2, 1999 | Closed |
1420 Williams Hwy, Grants Pass, OR 97526 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $105 | $105 | Jul 7, 1999 | Closed |
| Citation 1, item 2 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $105 | $105 | Jul 7, 1999 | Closed |
| Citation 2, item 3 29 CFR 1910.304(a)(2) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jul 7, 1999 | Closed |
| Citation 2, item 4 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 7, 1999 | Closed |
Morgan Project, North Hills Sub-division, Klamath Falls, OR 97603 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
500 Main Street, Klamath Falls, OR 97601 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3043 Ne 28th, Lincoln City, OR 97367 · OSHA's record · Phone and website on Google Maps
Incident on Mar 16, 1999: Employee fractures foot in fall from ladder
On March 15, 1999, Employee #1 was climbing a ladder onto the roof, when the lad der slipped out from under him. He fell approximately 12 feet to the ground. He fractured his foot and was hospitalized for his injury.
No citations from this inspection.
925 S Grape St, Medford, OR 97501 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.38(a)(2) · Emergency action plans |
Other-than-serious | $0 | $0 | Nov 18, 1998 | Closed |
| Citation 1, item 2 29 CFR 1910.134(f)(5)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Nov 18, 1998 | Closed |
| Citation 1, item 3 29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Nov 18, 1998 | Closed |
| Citation 1, item 4 | Other-than-serious | $0 | $0 | Nov 18, 1998 | Closed |
| Citation 1, item 5 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Nov 18, 1998 | Closed |
| Citation 1, item 6 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Nov 18, 1998 | Closed |
200 Block Of S Broadway, Coos Bay, OR 97420 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
43643 Hwy 62, Prospect, OR 97536 · OSHA's record · Phone and website on Google Maps
Incident on Jun 26, 1998: Burn - electrical fault in overhead line
A power line worker was changing the taps on a transformer to reduce the voltage to a customer's residence. The employee had climbed a utility pole that he was not able to access with his aerial lift. He opened one cutout and removed the co rresponding high-voltage-side connection on the transformer. He swung to the oth er side of the pole and removed the other high-voltage-side jumper without openi ng its cutout. As the employee opened the lid of the transformer, it apparently contacted the energized primary conductor, causing an electrical fault. The ensu ing electric arc and electric shock knocked the employee unconscious momentarily . After regaining consciousness, he was able to climb down the pole and walk to his truck to call for help. He was hospitalized with burns to his right hand.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 7010052 |
Other-than-serious | $250 | $250 | Aug 18, 1998 | Closed |
7200 Toketee School Rd, Idleyld Park, OR 97447 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $210 | $210 | Jul 24, 1998 | Closed |
135 W Lockhart, Coos Bay, OR 97420 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Jun 5, 1998 | Closed |
| Citation 1, item 2 | Other-than-serious | $0 | $0 | Jun 5, 1998 | Closed |
| Citation 1, item 3 | Other-than-serious | $0 | $0 | Jun 5, 1998 | Closed |
251 Valley View Road, Talent, OR 97540 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.453(a)(2)(v) · Aerial lifts |
Serious | $525 | $525 | Apr 23, 1998 | Closed |
100 Yds East Of Tolo & Blackwell Roads Intersect, Central Point, OR 97502 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.67(c)(2)(iv) · Vehicle-mounted elevating and rotating work platforms |
Serious | $105 | $105 | Jun 16, 1997 | Closed |
| Citation 1, item 2 29 CFR 1910.269(g)(2)(i) · Electric power generation, transmission, and distribution |
Serious | $105 | $105 | Jun 16, 1997 | Closed |
988 Commercial Street, Astoria, OR 97103 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
328 Webster, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Washburn Way Street Light Project, Klamath Falls, OR 97603 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $325 | $325 | Oct 7, 1996 | Final |
| Citation 2, item 2 | Serious | $600 | $600 | Oct 7, 1996 | Final |
Roseburg Service Center, 4025 Old Hwy 99s, Roseburg, OR 97470 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts |
Other-than-serious | $0 | $0 | Jul 5, 1996 | Closed |
| Citation 1, item 2 | Other-than-serious | $0 | $0 | Jul 5, 1996 | Closed |
| Citation 1, item 3 29 CFR 1910.184(e)(1) · Slings |
Other-than-serious | $0 | $0 | Jul 5, 1996 | Closed |
| Citation 1, item 4 29 CFR 1910.184(e)(3)(ii) · Slings |
Other-than-serious | $0 | $0 | Jul 5, 1996 | Closed |
| Citation 1, item 5 29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Jul 5, 1996 | Closed |
| Citation 1, item 6 29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Jul 5, 1996 | Closed |
Buena Vista Rd And Corvallis Hwy, Independence, OR 97351 · OSHA's record · Phone and website on Google Maps
Incident on Apr 8, 1996: Burn - electrical fault in meter base
An electrician was using a wire brush to clean a 240/480-volt meter base. He tho ught that he had opened the tap line to the meter base about one and a half mont hs earlier. However, he had actually opened another, nearby tap line, and the me ter base on which he was working was energized. The wire brush caused an electri cal fault, and the resultant electric arc burned the employee. He was hospitaliz ed with first- and second-degree burns to his hands, arms, and face.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.269(c)(3) · Electric power generation, transmission, and distribution |
Serious | $5,000 | $5,000 | May 29, 1996 | Closed |
| Citation 1, item 1b 29 CFR 1910.269(a)(3) · Electric power generation, transmission, and distribution |
Serious | $0 | $0 | May 29, 1996 | Closed |
| Citation 1, item 1c 29 CFR 1910.269(m)(3)(ii) · Electric power generation, transmission, and distribution |
Serious | $0 | $0 | May 29, 1996 | Closed |
Nw Corner Of Boardman & Edwards Streets, Medford, OR 97501 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1247 Se Montgomery St, Albany, OR 97321 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
550 Ne Skipinon, Warrenton, OR 97146 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(j)(2) · Excavations |
Other-than-serious | $0 | $0 | Oct 13, 1995 | Closed |
925 S Grape St, Medford, OR 97501 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $600 | $600 | Sep 5, 1995 | Closed |
| Citation 1, item 2 29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts |
Serious | $210 | $210 | Sep 5, 1995 | Closed |
| Citation 1, item 3 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Serious | $300 | $300 | Sep 5, 1995 | Closed |
| Citation 1, item 4 | Serious | $300 | $300 | Sep 5, 1995 | Closed |
| Citation 2, item 5 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Repeat | $200 | $200 | Sep 5, 1995 | Closed |
| Citation 2, item 6 29 CFR 1910.242(b) · Hand and power tools |
Repeat | $600 | $600 | Sep 5, 1995 | Closed |
| Citation 2, item 7 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Repeat | $400 | $400 | Sep 5, 1995 | Closed |
| Citation 3, item 8 29 CFR 1910.304(a)(2) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Sep 5, 1995 | Closed |
| Citation 3, item 9 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Sep 5, 1995 | Closed |
| Citation 3, item 10 29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Sep 5, 1995 | Closed |
| Citation 3, item 11 29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Sep 5, 1995 | Closed |
| Citation 3, item 12 29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Sep 5, 1995 | Closed |
| Citation 3, item 13 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 5, 1995 | Closed |
North Umpqua Project Box 76 Tokatee Route, Idleyld Park, OR 97447 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Box 76 Toketee Route, Idleyld Park, OR 97447 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3 29 CFR 1910.269(d)(2)(iv) · Electric power generation, transmission, and distribution |
Serious | $210 | $150 | Jun 5, 1995 | Final |
| Citation 1, item 4 29 CFR 1910.269(d)(v)(e) · Electric power generation, transmission, and distribution |
Serious | $210 | $150 | Jun 5, 1995 | Final |
| Citation 1, item 5 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $210 | $210 | Jun 5, 1995 | Closed |
| Citation 1, item 6a 29 CFR 1910.213(h)(1) · Woodworking machinery |
Serious | $150 | $150 | Jun 5, 1995 | Closed |
| Citation 1, item 6b 29 CFR 1910.213(h)(4) · Woodworking machinery |
Serious | $0 | $0 | Jun 5, 1995 | Closed |
| Citation 1, item 7 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $450 | $450 | Jun 5, 1995 | Closed |
| Citation 2, item 8 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Jun 5, 1995 | Closed |
| Citation 2, item 9 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jun 5, 1995 | Closed |
10th & Applegate St, Philomath, OR 97370 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 2, item 2 29 CFR 1910.269(g)(2)(iii) · Electric power generation, transmission, and distribution |
Other-than-serious | $0 | $0 | Feb 28, 1995 | Final |
Hwy 395, Pendleton, OR 97801 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2nd & Revere, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(e)(6)(ii) · Flammable liquids |
Other-than-serious | $0 | $0 | Jul 15, 1994 | Closed |
| Citation 1, item 2 29 CFR 1910.1200(f)(5) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 15, 1994 | Closed |
640 Kennedy St, Echo, Echo, OR 97826 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
925 S Grape St, Medford, OR 97501 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $150 | $150 | Dec 30, 1993 | Closed |
| Citation 1, item 2 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $150 | $150 | Dec 30, 1993 | Closed |
| Citation 2, item 3 29 CFR 1910.242(b) · Hand and power tools |
Other-than-serious | $0 | $0 | Dec 30, 1993 | Closed |
| Citation 2, item 4 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Dec 30, 1993 | Closed |
102 Nevada St, Klamath Falls, OR 97601 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $240 | $240 | Jan 11, 1994 | Closed |
1007 Ne 8th Street, Grants Pass, OR 97526 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms |
Serious | $150 | $150 | Jul 29, 1993 | Closed |
| Citation 1, item 2a 29 CFR 7020305 |
Serious | $150 | $150 | Jul 29, 1993 | Closed |
| Citation 1, item 2b 29 CFR 7020067 |
Serious | $0 | $0 | Jul 29, 1993 | Closed |
Bonanza & Buckley Streets, Echo, OR 97826 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
711 Broadway St, Seaside, OR 97138 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $750 | $750 | Apr 29, 1993 | Closed |
29125 Casting St, Wilsonville, OR 97070 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $210 | $210 | May 14, 1993 | Closed |
| Citation 2, item 2 | Other-than-serious | $0 | $0 | May 14, 1993 | Closed |
Anheny Hill Rd Pole #230600, Jefferson, OR 97352 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $210 | $150 | Feb 22, 1993 | Final |
615 Holley Street, Junction City, OR 97448 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Other-than-serious | $0 | $0 | Feb 25, 1992 | Closed |
935 N Crest, Central Point, OR 97502 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
61155 S Highway 97, Bend, OR 97702 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.951(a)(2) · Medical services and first aid |
Other-than-serious | $0 | $0 | Dec 1, 1989 | Closed |
Southwest Corner Of 4th And Underwood, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 7030420 |
Other-than-serious | $0 | $0 | Jul 31, 1989 | Closed |
Corner Of 8th & Spruce, Myrtle Point, OR 97458 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Shore Pines Trailer Park, Coos Bay, OR 97420 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 7840213 |
Other-than-serious | $0 | $0 | Nov 10, 1988 | Closed |
Across From 2879 Pheasant, Springfield, OR 97477 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1428 Garden Valley Blvd, Roseburg, OR 97470 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
29125 Casting Street, Wilsonville, OR 97070 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Main St, Eugene, OR 97401 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 7833106 |
Other-than-serious | $0 | $0 | Dec 29, 1987 | Closed |
| Citation 1, item 2 29 CFR 7840263 |
Other-than-serious | $0 | $0 | Dec 29, 1987 | Closed |
| Citation 1, item 3 29 CFR 7841063 |
Other-than-serious | $0 | $0 | Dec 29, 1987 | Closed |
Corner 10th & Madison St, Cottage Grove, OR 97424 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 7840286 |
Other-than-serious | $0 | $0 | Oct 8, 1986 | Closed |
610 Sw Alder, Portland, OR 97205 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $45 | $45 | Jul 31, 1986 | Closed |
| Citation 2, item 2 29 CFR 4250003 A |
Other-than-serious | $0 | $0 | Jul 31, 1986 | Closed |
1019 Sw Morrison, Portland, OR 97205 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 4250003 A |
Other-than-serious | $0 | $0 | Jul 31, 1986 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Portland site logged 0 recordable injuries or illnesses among about 793 workers: 0.0 per 100 full-time workers, against a median of 1.0 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| 00482 Zdnulloyd CTR Tower Portland · 2025 | 793 | 0 | 0 | 0.0 | 1.0 |
| 00457 Grape Street Ofc Medford · 2025 | 118 | 1 | 0 | 0.8 | 1.0 |
| 00468 System PWR CNTRL CTR Portland · 2025 | 104 | 0 | 0 | 0.0 | 1.0 |
| 00451 Willamette Ops Albany · 2025 | 77 | 0 | 0 | 0.0 | 1.0 |
| 00169 Central OR OPS Center Bend · 2025 | 67 | 0 | 0 | 0.0 | 1.0 |
| 00419 Klamath Falls Opns Klamath Falls · 2025 | 57 | 1 | 1 | 1.8 | 1.0 |
| 00414 Grants Pass Opns CTR Grants Pass · 2025 | 52 | 0 | 0 | 0.0 | 1.0 |
| 00463 Roseburg Cust SVC CNTR Roseburg · 2025 | 51 | 0 | 0 | 0.0 | 1.0 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(e)(6)(ii)
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.1200(f)(5)
(f) Any organic peroxide which, in laboratory testing, neither detonates in the cavitated state nor deflagrates at all and shows only a low or no effect when heated under confinement as well as low or no explosive power shall be defined as organic peroxide TYPE F;
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.