OSHA SearchOSHA records by employer

Plasticraft Manufacturing Co., Inc.: OSHA inspections and violations

Albertville, Alabama · All Other Plastics Product Manufacturing · NAICS 326199

5inspections
24citation items
$27,129current penalties
Apr 8, 2015last inspection

OSHA has inspected Plasticraft Manufacturing Co., Inc. 5 times in Alabama since 2006.

The latest one began on Apr 8, 2015 on a referral, in Albertville.

Those inspections ended with 24 citation items: 21 serious, 1 repeat and 2 other-than-serious.

Penalties were first proposed at $34,865 and now stand at $27,129, 22% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 4 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Plasticraft Manufacturing Co., Inc. averages $7,070 (2 cited inspections).

Plasticraft Manufacturing Co., Inc.: OSHA citation items per year, 2006 to 2015
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

95employers cited

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Plasticraft Manufacturing Co., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340525708 OPENED APR 8, 2015Closed

Referral · Partial · Safety · 45 employees at the site · Closed Jul 14, 2015

115 Plasticraft Drive, Albertville, AL 35951 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$3,850$3,850Jun 15, 2015Final
Citation 1, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$5,390$5,390Jun 15, 2015Final

Inspection 340184530 OPENED JAN 15, 2015Closed

Unprogrammed related · Partial · Safety · 50 employees at the site · Closed Apr 27, 2015

115 Plasticraft Drive, Albertville, AL 35951 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$4,900$4,900Mar 26, 2015Final

Inspection 315458109 OPENED MAY 4, 2011Closed

Planned · Complete · Health · 47 employees at the site · Closed Jul 6, 2011

115 Plasticraft Drive, Albertville, AL 35951 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a)(2) · Exit routes
Serious$2,800$1,680May 12, 2011Closed
Citation 1, item 2a
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$2,100$1,260May 12, 2011Closed
Citation 1, item 2b
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$0$0May 12, 2011Closed
Citation 1, item 3
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$2,800$1,680May 12, 2011Closed
Citation 2, item 1
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Repeat$5,600$2,800May 12, 2011Closed
Citation 3, item 1
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0May 12, 2011Closed

Inspection 312767486 OPENED FEB 12, 2009Closed

Planned · Complete · Safety · 57 employees at the site · Closed Feb 17, 2009

115 Plasticraft Drive, Albertville, AL 35951 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310164751 OPENED SEP 6, 2006Closed

Planned · Complete · Health · 130 employees at the site · Closed Nov 14, 2006

115 Plasticraft Drive, Albertville, AL 35951 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$1,100$825Oct 10, 2006Closed
Citation 1, item 1b Serious$0$0Oct 10, 2006Closed
Citation 1, item 1c Serious$0$0Oct 10, 2006Closed
Citation 1, item 2a
29 CFR 1910.106(d)(3)(i) · Flammable liquids
Serious$1,100$825Oct 10, 2006Closed
Citation 1, item 2b
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0Oct 10, 2006Closed
Citation 1, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$825$619Oct 10, 2006Closed
Citation 1, item 3b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Oct 10, 2006Closed
Citation 1, item 3c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Oct 10, 2006Closed
Citation 1, item 4
29 CFR 1910.176(b) · Material storage and aisles
Serious$1,100$825Oct 10, 2006Closed
Citation 1, item 5a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$1,100$825Oct 10, 2006Closed
Citation 1, item 5b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Oct 10, 2006Closed
Citation 1, item 6
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$1,100$825Oct 10, 2006Closed
Citation 1, item 7a
29 CFR 1910.1030(c)(1)(iv) · Bloodborne pathogens
Serious$1,100$825Oct 10, 2006Closed
Citation 1, item 7b
29 CFR 1910.1030(g)(2)(iic) · Bloodborne pathogens
Serious$0$0Oct 10, 2006Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Oct 10, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(iv)

(iv) The Exposure Control Plan shall be reviewed and updated at least annually and whenever necessary to reflect new or modified tasks and procedures which affect occupational exposure and to reflect new or revised employee positions with occupational exposure. The review and update of such plans shall also:

29 CFR 1910.1030(g)(2)(iic)

(ii) Training shall be provided as follows:

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(i)

(3) Design, construction, and capacity of storage cabinets—(i) Maximum capacity. Not more than 60 gallons of Category 1, 2, or 3 flammable liquids, nor more than 120 gallons of Category 4 flammable liquids may be stored in a storage cabinet.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other all other plastics product manufacturing employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.