Plastics Engineering Company: OSHA inspections and violations
Sheboygan, Wisconsin · Plastics Material and Resin Manufacturing · NAICS 325211
11inspections
37citation items
$106,169current penalties
Nov 19, 2024last inspection
Plastics Engineering Company has 11 OSHA inspections on record in Wisconsin, the first in 1974.
OSHA's last visit started on Nov 19, 2024 on a referral, in Sheboygan.
Across those inspections OSHA issued 37 citation items: 19 serious and 18 other-than-serious.
OSHA proposed $145,906 in penalties. After settlements and reviews the total is $106,169, down 27%.
Most often, OSHA cited 1910.119, process safety management (13 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Plastics Engineering Company averages $34,477 over 3 cited inspections in that time.
Plastics Engineering Company also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Wisconsin · latest 90 days of OSHA records
229employers cited
Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Plastics Engineering Company and get notified the morning OSHA posts a new citation for it.
Incident on Jul 11, 2005: Employees are burned in phenol pipe failure
On July 11, 2005, Employees #1 through #3, with Plastic Engineering Company, wer e removing a blockage in a phenol pipe line. Prior to removing the pump, the emp loyees had verified the valves were working correctly, the valves were open, eac h end of the pipe section was open to atmosphere. In addition, pressurized steam was introduced on one end of the pipe section and observed leaving from the oth er end. When Employees #1 and #2 (maintenance workers) separated the pump head f rom the centrifugal pump casing base, a steam/phenol mixture sprayed all three e mployees. Employees #1 through #3 were hospitalized for thermal/chemical burns t o their faces, necks and legs. The two maintenance workers were next to the pump and were wearing safety boots, typical work clothing, neoprene chemical resista nt jackets, face shields and safety glasses. Employee #3 (an electrician) was st anding in doorway approximately 10 ft away and wearing safety boots, typical wor k clothing and safety glasses. Emergency showers, additional water sources, and phenol soap were available within 20 ft of the incident.
Citation and rule
Type
Proposed
Current
Issued
Status
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious
$2,625
$1,838
Jan 9, 2006
Closed
Inspection 304011562 OPENED NOV 2, 2001Closed
Referral · Partial · Health · 450 employees at the site · Closed Jul 10, 2002
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Sheboygan site logged 4 recordable injuries or illnesses among about 245 workers: 1.8 per 100 full-time workers, against a median of 1.1 for its industry. Those cases cost 1 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Plastics Engineering Company
Sheboygan · 2025
245
4
1
1.8
1.1
Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
Nov 8, 2024, Sheboygan: Hospitalization · amputations involving bone loss · other finger(s) n.e.c.
On November 8, 2024, an employee climbed onto a machine belt to clear a jammed chunk of plastic from between two heated rollers. The employee deenergized the machine, but the rollers were still coasting. The employee's gloved hand was pulled into the rollers and became trapped between the heated rollers (~330 F) for approximately 12 minutes. The employee was hospitalized with severe burns to the…
Aug 17, 2017, Sheboygan: Hospitalization · second degree heat (thermal) burns · multiple body parts, n.e.c.
An employee was working on a mixer when a flash fire occurred. He suffered first degree burns to the left arm, hand, and face and second degree burns on his left arm and other areas.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(l) Employee information and training—(1) Training program. (i) Each employer who has a workplace in which there is a potential exposure to airborne lead at any level shall inform employees of the content of Appendices A and B of this regulation.
29 CFR 1910.1025(l)(2)(i)
(2) Access to information and training materials. (i) The employer shall make readily available to all affected employees a copy of this standard and its appendices.
(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.
Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.