OSHA SearchOSHA records by employer

Raw Welding Inc.: OSHA inspections and violations

Falmouth, Massachusetts · Structural Steel and Precast Concrete Contractors · NAICS 238120

1inspections
5citation items
$23,407current penalties
Oct 30, 2024last inspection

OSHA inspectors have visited Raw Welding Inc. in Massachusetts one time.

It opened on Oct 30, 2024 on a referral, in Falmouth and is still open.

In all, OSHA issued 5 citation items: 5 serious.

The penalties, $23,407 in total, stand where OSHA first set them.

The rule cited most here is 1926.753 (hoisting and rigging), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Raw Welding Inc. averages $23,407 across 1 cited inspection.

Raw Welding Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

235employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Raw Welding Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347852998 OPENED OCT 30, 2024Open

Referral · Partial · Safety · 6 employees at the site · Open

550 Main Street, Falmouth, MA 02540 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$4,965$4,965Apr 23, 2025Final
Citation 1, item 2
29 CFR 1926.752(d) · Site layout, site-specific erection plan and construction sequence
Serious$4,965$4,965Apr 23, 2025Final
Citation 1, item 3a
29 CFR 1926.753(c)(2) · Hoisting and rigging
Serious$3,547$3,547Apr 23, 2025Final
Citation 1, item 3b
29 CFR 1926.753(d)(2)(iii) · Hoisting and rigging
Serious$4,965$4,965Apr 23, 2025Final
Citation 1, item 5
29 CFR 1926.761(b) · Training
Serious$4,965$4,965Apr 23, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.752 · Site layout, site-specific erection plan and construction sequence

29 CFR 1926.752(d)

(d) Pre-planning of overhead hoisting operations. All hoisting operations in steel erection shall be pre-planned to ensure that the requirements of § 1926.753(d) are met.

29 CFR 1926.753 · Hoisting and rigging

29 CFR 1926.753(c)(2)

(2) A qualified rigger (a rigger who is also a qualified person) shall inspect the rigging prior to each shift in accordance with § 1926.251.

29 CFR 1926.761 · Training

Other structural steel and precast concrete contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.