Reliable Tool & Machine: OSHA inspections and violations
Kendallville, Indiana · Other Motor Vehicle Parts Manufacturing · NAICS 336399
9inspections
42citation items
$9,987current penalties
Nov 15, 2023last inspection
OSHA has inspected Reliable Tool & Machine 9 times in Indiana since 1983.
The latest one began on Nov 15, 2023 on a referral, in Kendallville.
Those inspections ended with 42 citation items: 12 serious and 30 other-than-serious.
Penalties were first proposed at $20,000 and now stand at $9,987, 50% lower after settlements or reviews.
Belts, pulleys and power-transmission parts comes up most often in these citations: 5 items under 1910.219.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Reliable Tool & Machine averages $3,640 (1 cited inspection).
Reliable Tool & Machine also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Indiana · latest 90 days of OSHA records
75employers cited
Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Kendallville site logged 6 recordable injuries or illnesses among about 107 workers: 5.4 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 15 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Reliable Tool and Machine, Inc
Kendallville · 2025
107
6
1
5.4
2.7
Reliable Tool & Machine Co., Inc.
Kendallville · 2024
134
1
0
0.7
2.7
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.110 · Storage and handling of liquefied petroleum gases
29 CFR 1910.110(e)(4)(iii)
(iii) Permanent and removable fuel containers shall be securely mounted to prevent jarring loose, slipping, or rotating, and the fastenings shall be designed and constructed to withstand static loading in any direction equal to twice the weight of the tank and attachments when filled with fuel using a safety factor of not less than four based on the ultimate strength of the material to be used. Field welding, when necessary, shall be made only on saddle plates, lugs or brackets, originally attached to the container by the tank manufacturer.
Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.