Rocky Mountain Steel Inc.: OSHA inspections and violations
Olathe, Colorado · Fabricated Structural Metal Manufacturing · NAICS 332312
8inspections
18citation items
$10,875current penalties
Apr 7, 2021last inspection
Rocky Mountain Steel Inc. has 8 OSHA inspections on record in Colorado, the first in 1999.
OSHA's last visit started on Apr 7, 2021 as a planned inspection, in Olathe.
Across those inspections OSHA issued 18 citation items: 8 serious and 10 other-than-serious.
OSHA proposed $20,236 in penalties. After settlements and reviews the total is $10,875, down 46%.
Most often, OSHA cited 1910.134, respiratory protection (5 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Rocky Mountain Steel Inc. averages $5,000 over 1 cited inspection in that time.
Rocky Mountain Steel Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Colorado · latest 90 days of OSHA records
138employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Olathe site logged 3 recordable injuries or illnesses among about 41 workers: 7.6 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 6 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Rocky Mountain Steel Inc.
Olathe · 2025
41
3
2
7.6
3.6
Rocky Mountain Steel, Inc.
Olathe · 2023
32
3
0
90.6
3.6
Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
29 CFR 1910.134(f)(2)
(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.
Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.