OSHA SearchOSHA records by employer

Ronnie Demeo Construction, Inc.: OSHA inspections and violations

Madison, Connecticut · Masonry Contractors · NAICS 238140

29inspections
100citation items
$177,942current penalties
Apr 10, 2026last inspection

OSHA has inspected Ronnie Demeo Construction, Inc. 29 times in Connecticut since 1988.

The latest one began on Apr 10, 2026 after a complaint, in Naugatuck; the case is still open.

Those inspections ended with 100 citation items: 78 serious, 11 repeat and 11 other-than-serious.

Penalties were first proposed at $270,673 and now stand at $177,942, 34% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 58 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Ronnie Demeo Construction, Inc. averages $15,680 (6 cited inspections).

Ronnie Demeo Construction, Inc. also files yearly injury logs with OSHA, summarized below.

Ronnie Demeo Construction, Inc.: OSHA citation items per year, 1988 to 2026
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

88employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Ronnie Demeo Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348884958 OPENED APR 10, 2026Open

Complaint · Partial · Safety · 8 employees at the site · Open

20 Old Firehouse Road, Naugatuck, CT 06770 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.454(c)(3) · Scaffold training
Serious$9,931$4,966May 14, 2026Final
Citation 2, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$19,863$9,932May 14, 2026Final
Citation 2, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$19,863$9,932May 14, 2026Final

Inspection 346943624 OPENED AUG 28, 2023Closed

Complaint · Partial · Safety · 9 employees at the site · Closed Mar 4, 2025

29 Bell Street, Stamford, CT 06902 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$11,292$7,900Feb 23, 2024Final

Inspection 346047863 OPENED JUN 28, 2022Closed

Complaint · Partial · Safety · 60 employees at the site · Closed Feb 14, 2024

373 East Main Street Building C, Branford, CT 06405 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$6,164$3,750Dec 23, 2022Final
Citation 1, item 2
29 CFR 1926.1153(c)(1) · Silica dust in construction
Serious$6,164$3,750Dec 23, 2022Final

Inspection 345160048 OPENED FEB 23, 2021Closed

Referral · Partial · Safety · 40 employees at the site · Closed Mar 8, 2021

150 Dividend Road, Rocky Hill, CT 06067 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343495651 OPENED SEP 26, 2018Closed

Planned · Partial · Safety · 25 employees at the site · Closed Mar 20, 2019

260 Oxford Road, Oxford, CT 06478 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342058542 OPENED JAN 25, 2017Closed

Planned · Partial · Safety · 35 employees at the site · Closed Apr 5, 2023

580 Captain Neville Dr., Waterbury, CT 06705 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Repeat$34,858$22,300Feb 13, 2017Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Repeat$19,520$12,590Feb 13, 2017Final
Citation 1, item 3
29 CFR 1926.454(a)(1) · Scaffold training
Repeat$13,943$9,510Feb 13, 2017Final

Inspection 340801299 OPENED JUL 17, 2015Closed

Planned · Partial · Safety · 11 employees at the site · Closed Sep 16, 2015

135 Sanford Street, Hamden, CT 06514 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340640069 OPENED MAY 18, 2015Closed

Planned · Partial · Safety · 35 employees at the site · Closed Oct 26, 2015

Storrs Center, Storrs Road, Mansfield Center, CT 06235 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,500$1,750Jul 16, 2015Final
21 older inspections

Inspection 340491109 OPENED FEB 5, 2015Closed

Referral · Complete · Safety · 40 employees at the site · Closed Sep 25, 2017

35 Beachside Ave, Westport, CT 06880 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.350(a)(9) · Gas welding and cutting
Serious$2,800$1,500Apr 14, 2015Final
Citation 1, item 2
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$4,900$3,100Apr 14, 2015Final
Citation 1, item 3
29 CFR 1926.451(f)(12) · Scaffolds, general requirements
Serious$4,900$3,100Apr 14, 2015Final

Inspection 339623258 OPENED MAR 7, 2014Closed

Planned · Partial · Safety · 10 employees at the site · Closed Apr 18, 2016

470 Lewis Ave., Meriden, CT 06451 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,800$2,200Apr 29, 2014Final
Citation 1, item 2a
29 CFR 1926.451(e)(5)(i) · Scaffolds, general requirements
Serious$2,800$2,200Apr 29, 2014Final
Citation 1, item 2b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Apr 29, 2014Final
Citation 1, item 3
29 CFR 1926.454(a)(1) · Scaffold training
Serious$2,000$1,600Apr 29, 2014Final
Citation 2, item 1
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Repeat$5,600$4,500Apr 29, 2014Final

Inspection 338985013 OPENED MAR 28, 2013Closed

Planned · Partial · Safety · 15 employees at the site · Closed Jun 27, 2014

Rt 15 Southbound Rest Plaza, Greenwich, CT 06830 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Other-than-serious$2,200$500Apr 24, 2013Final
Citation 1, item 3
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Other-than-serious$3,080$1,000Apr 24, 2013Final

Inspection 315235481 OPENED FEB 24, 2011Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed Jan 11, 2012

44 Banner Drive, Milford, CT 06460 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.29(b)(1) · Injury and illness log
Repeat$1,540$1,078Jun 10, 2011Closed
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Jun 10, 2011Closed

Inspection 314617200 OPENED JUL 26, 2010Closed

Unprogrammed other · Partial · Safety · 30 employees at the site · Closed Nov 7, 2013

80 Flat Rock Pl, Westbrook, CT 06498 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$1,000$700Dec 2, 2010Closed
Citation 2, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$6,000$4,200Dec 2, 2010Closed

Inspection 312882301 OPENED FEB 19, 2009Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jul 11, 2013

20 Compo Road, Westport, CT 06880 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Repeat$2,000$1,540May 12, 2009Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$4,000$3,080May 12, 2009Closed
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,000$3,600May 12, 2009Closed
Citation 1, item 5
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$1,600$1,400May 12, 2009Closed

Inspection 311759955 OPENED NOV 4, 2008Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 21, 2009

Hampton Inn, Rte. 6, Farmington, CT 06032 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,000$3,000Dec 8, 2008Closed

Inspection 311366892 OPENED NOV 1, 2007Closed

Unprogrammed related · Partial · Safety · 50 employees at the site · Closed Sep 16, 2010

180 Main St., Deep River, CT 06419 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$900$720Feb 14, 2008Closed
Citation 1, item 3
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,000$2,300Feb 14, 2008Closed
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,000$2,300Feb 14, 2008Closed
Citation 1, item 5
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,000$2,300Feb 14, 2008Closed
Citation 1, item 6
29 CFR 1926.451(g)(4)(ii) · Scaffolds, general requirements
Serious$1,500$1,160Feb 14, 2008Closed
Citation 1, item 7
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,160Feb 14, 2008Closed
Citation 1, item 8a
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$1,500$1,160Feb 14, 2008Closed
Citation 1, item 8b
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$0$0Feb 14, 2008Closed
Citation 1, item 9
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$3,000$2,300Feb 14, 2008Closed
Citation 1, item 10
29 CFR 1926.706(a)(1) · Requirements for masonry construction
Serious$1,500$1,160Feb 14, 2008Closed
Citation 1, item 11
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$1,200$960Feb 14, 2008Closed
Citation 1, item 12
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$2,100$1,680Feb 14, 2008Closed
Citation 1, item 13
29 CFR 1926.1053(b)(15) · Ladders in construction
Serious$900$720Feb 14, 2008Closed
Citation 1, item 14
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$1,500$1,160Feb 14, 2008Closed
Citation 2, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$3,000$1,500Feb 14, 2008Closed
Citation 2, item 2
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$3,000$1,500Feb 14, 2008Closed
Citation 3, item 1a
29 CFR 1904.29(b)(1) · Injury and illness log
Other-than-serious$600$480Feb 14, 2008Closed
Citation 3, item 1b
29 CFR 1904.32(b)(2) · Yearly injury summary
Other-than-serious$0$0Feb 14, 2008Closed

Inspection 310920640 OPENED MAY 2, 2007Closed

Referral · Partial · Safety · 25 employees at the site · Closed Jul 3, 2007

90 Ivy Brook Rd, Shelton, CT 06484 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$2,000$1,000Jun 21, 2007Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,000$500Jun 21, 2007Closed

Inspection 308297712 OPENED MAR 22, 2005Closed

Unprogrammed related · Partial · Safety · 25 employees at the site · Closed Jun 8, 2005

80 Flat Rock Pl, Westbrook, CT 06498 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.451(h)(2) · Scaffolds, general requirements
Serious$800$400May 6, 2005Closed

Inspection 304394380 OPENED MAR 14, 2002Closed

Planned · Partial · Safety · 25 employees at the site · Closed May 7, 2002

1291 Boston Post Road, Madison, CT 06443 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,000$1,000Mar 20, 2002Closed

Inspection 116144734 OPENED NOV 7, 2001Closed

Unprogrammed related · Partial · Safety · 25 employees at the site · Closed Apr 24, 2002

Hammer Mill Road, Rocky Hill, CT 06067 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,000$500Nov 19, 2001Closed
Citation 2, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Repeat$2,000$1,000Nov 19, 2001Closed

Inspection 300084845 OPENED AUG 22, 2001Closed

Referral · Partial · Safety · 14 employees at the site · Closed Aug 28, 2001

25 International Drive, Windsor, CT 06095 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 116129925 OPENED AUG 9, 2000Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed Jan 19, 2001

35 Chestnut Street, Norwich, CT 06360 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.250(b)(5) · General requirements for storage
Serious$800$400Oct 17, 2000Closed
Citation 1, item 3a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,000$1,000Oct 17, 2000Closed
Citation 1, item 3b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Oct 17, 2000Closed
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$750$375Oct 17, 2000Closed
Citation 1, item 5
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$450$225Oct 17, 2000Closed
Citation 1, item 6a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,500$750Oct 17, 2000Closed
Citation 1, item 6b
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$0$0Oct 17, 2000Closed

Inspection 123169385 OPENED MAR 1, 1995Closed

Unprogrammed other · Complete · Safety · 15 employees at the site · Closed Mar 20, 2003

1291 Boston Post Road, Madison, CT 06443 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$1,050$1,050Mar 31, 1995Closed
Citation 2, item 1
29 CFR 1926.451(a)(8) · Scaffolds, general requirements
Other-than-serious$0$0Mar 31, 1995Closed

Inspection 109852384 OPENED SEP 20, 1994Closed

Unprogrammed related · Complete · Safety · 13 employees at the site · Closed Feb 25, 2003

100 Signature Way, Taxiway J Building, Windsor Locks, CT 06096 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$2,500$2,500Nov 10, 1994Closed
Citation 1, item 2a
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$3,000$3,000Nov 10, 1994Closed
Citation 1, item 2b
29 CFR 1926.451(d)(4) · Scaffolds, general requirements
Serious$0$0Nov 10, 1994Closed
Citation 1, item 3
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$900$900Nov 10, 1994Closed
Citation 2, item 1
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Repeat$4,200$4,200Nov 10, 1994Closed

Inspection 109852624 OPENED AUG 10, 1994Closed

Referral · Partial · Safety · 5 employees at the site · Closed Mar 29, 2004

Hale Road, Bernie's, Manchester, CT 06040 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$1,000$1,000Sep 19, 1994Closed
Citation 1, item 1b
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$0$0Sep 19, 1994Closed
Citation 1, item 1c
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$0$0Sep 19, 1994Closed
Citation 2, item 1
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Repeat$2,000$2,000Sep 19, 1994Closed

Inspection 123213993 OPENED JUL 13, 1993Closed

Planned · Complete · Safety · 9 employees at the site · Closed Apr 4, 1994

540 Litchfield Street/charlotte Hungerford Hosp., Torrington, CT 06790 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$525$525Aug 23, 1993Closed
Citation 1, item 2
29 CFR 1926.451(a)(2) · Scaffolds, general requirements
Serious$525$525Aug 23, 1993Closed
Citation 1, item 3
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Serious$525$525Aug 23, 1993Closed
Citation 2, item 1
29 CFR 1926.59(g)(1) · Hazard communication
Other-than-serious$0$0Aug 23, 1993Closed

Inspection 113213342 OPENED FEB 18, 1993Closed

Planned · Complete · Safety · 9 employees at the site · Closed Sep 13, 1993

1291 Boston Post Road, Madison, CT 06443 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Serious$600$360Mar 8, 1993Closed
Citation 1, item 2
29 CFR 1926.59(h) · Hazard communication
Serious$600$360Mar 8, 1993Closed
Citation 1, item 3
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$2,000$1,210Mar 8, 1993Closed
Citation 1, item 4
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$2,000$1,210Mar 8, 1993Closed
Citation 1, item 5
29 CFR 1926.601(b)(3) · Motor vehicles
Serious$600$360Mar 8, 1993Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Mar 8, 1993Closed

Inspection 101004364 OPENED JUL 31, 1989Closed

Planned · Complete · Safety · 7 employees at the site · Closed Nov 30, 1989

44 Lake Avenue Extension, Danbury, CT 06810 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$810$810Oct 31, 1989Closed
Citation 1, item 1b
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Oct 31, 1989Closed
Citation 1, item 1c
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$0$0Oct 31, 1989Closed
Citation 1, item 1d
29 CFR 1926.451(d)(7) · Scaffolds, general requirements
Serious$0$0Oct 31, 1989Closed
Citation 1, item 1e
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$0$0Oct 31, 1989Closed
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$250$250Oct 31, 1989Closed
Citation 1, item 3
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$200$200Oct 31, 1989Closed
Citation 2, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Oct 31, 1989Closed
Citation 2, item 2
29 CFR 1926.59(g)(1) · Hazard communication
Other-than-serious$0$0Oct 31, 1989Closed
Citation 2, item 3
29 CFR 1926.59(h) · Hazard communication
Other-than-serious$0$0Oct 31, 1989Closed

Inspection 102738507 OPENED OCT 12, 1988Closed

Referral · Partial · Safety · 7 employees at the site · Closed Apr 11, 1989

32 Shunpike Road, Cromwell, CT 06416 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$810$810Jan 27, 1989Closed
Citation 1, item 2a
29 CFR 1926.451(d)(3) · Scaffolds, general requirements
Serious$560$560Jan 27, 1989Closed
Citation 1, item 2b
29 CFR 1926.451(d)(4) · Scaffolds, general requirements
Serious$0$0Jan 27, 1989Closed
Citation 1, item 2c
29 CFR 1926.451(d)(6) · Scaffolds, general requirements
Serious$0$0Jan 27, 1989Closed
Citation 1, item 2d
29 CFR 1926.451(d)(7) · Scaffolds, general requirements
Serious$0$0Jan 27, 1989Closed
Citation 1, item 3
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$560$560Jan 27, 1989Closed
Citation 1, item 4a
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$640$640Jan 27, 1989Closed
Citation 1, item 4b
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$0$0Jan 27, 1989Closed
Citation 1, item 4c
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$0$0Jan 27, 1989Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Rocky Hill site logged 1 recordable injury or illness among about 50 workers: 2.9 per 100 full-time workers, against a median of 2.8 for its industry. Those cases cost 5 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Ronnie DeMeo Construction Inc.
Rocky Hill · 2022
50 112.92.8

Included with any plan: 5 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(b)(1)

(b) Implementation—(1) What do I need to do to complete the OSHA 300 Log? You must enter information about your business at the top of the OSHA 300 Log, enter a one or two line description for each recordable injury or illness, and summarize this information on the OSHA 300-A at the end of the year.

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(b)(2)

(2) How do I complete the annual summary? You must:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.25 · Housekeeping

29 CFR 1926.250 · General requirements for storage

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.59 · Hazard communication

29 CFR 1926.601 · Motor vehicles

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.706 · Requirements for masonry construction

Other masonry contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.