OSHA SearchOSHA records by employer

Royston, LLC: OSHA inspections and violations

Jackson, Tennessee · Showcase, Partition, Shelving, and Locker Manufacturing · NAICS 337215

6inspections
39citation items
$23,854current penalties
Apr 20, 2015last inspection

Royston, LLC has 6 OSHA inspections on record in Tennessee, the first in 2007.

OSHA's last visit started on Apr 20, 2015 as a planned inspection, in Jackson.

Across those inspections OSHA issued 39 citation items: 19 serious, 2 repeat and 18 other-than-serious.

OSHA proposed $29,050 in penalties. After settlements and reviews the total is $23,854, down 18%.

Most often, OSHA cited 1910.107, spray painting and finishing (7 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Royston, LLC averages $1,800 over 1 cited inspection in that time.

Royston, LLC: OSHA citation items per year, 2007 to 2015
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

353employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Royston, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340568443 OPENED APR 20, 2015Closed

Planned · Complete · Health · 45 employees at the site · Closed Jun 3, 2015

920 Richmond Street, Jackson, TN 38301 · Reconstituted Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(6) · Spray painting and finishing
Serious$1,800$1,800May 7, 2015Final
Citation 1, item 1b
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0May 7, 2015Final
Citation 2, item 1a
29 CFR 1910.1030(h)(2)(i)(b) · Bloodborne pathogens
Other-than-serious$0$0May 7, 2015Final
Citation 2, item 1b
29 CFR 1910.1030(h)(2)(i)(c) · Bloodborne pathogens
Other-than-serious$0$0May 7, 2015Final

Inspection 317488278 OPENED DEC 4, 2013Closed

Follow-up · Partial · Safety · 50 employees at the site · Closed Jan 24, 2014

920 Richmond Street, Jackson, TN 38301 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Repeat$2,500$2,500Dec 19, 2013Closed
Citation 2, item 1
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$100$100Dec 19, 2013Closed

Inspection 317161958 OPENED MAY 22, 2013Closed

Planned · Complete · Safety · 46 employees at the site · Closed Aug 9, 2013

920 Richmond Street, Jackson, TN 38301 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$3,500$2,883Jun 21, 2013Closed
Citation 1, item 2a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,000$1,383Jun 21, 2013Closed
Citation 1, item 2b
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$0$0Jun 21, 2013Closed
Citation 1, item 2c
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Jun 21, 2013Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Repeat$1,250$1,250Jun 21, 2013Closed
Citation 3, item 1
29 CFR 1910.22(a)(2) · General requirements
Other-than-serious$250$250Jun 21, 2013Closed
Citation 3, item 2
29 CFR 1910.138(a) · Gloves and hand protection
Other-than-serious$250$250Jun 21, 2013Closed
Citation 3, item 3
29 CFR 3000403 B 3
Other-than-serious$2,000$1,383Jun 21, 2013Closed

Inspection 314395898 OPENED APR 23, 2010Closed

Planned · Complete · Safety · 20 employees at the site · Closed Aug 9, 2010

920 Richmond Street, Jackson, TN 38301 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$1,400$1,050Jun 10, 2010Closed
Citation 1, item 1b
29 CFR 1910.107(e)(9) · Spray painting and finishing
Serious$0$0Jun 10, 2010Closed
Citation 1, item 2a
29 CFR 1910.107(b)(3) · Spray painting and finishing
Serious$1,400$1,050Jun 10, 2010Closed
Citation 1, item 2b
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Jun 10, 2010Closed
Citation 1, item 3
29 CFR 1910.107(c)(4) · Spray painting and finishing
Serious$1,750$1,300Jun 10, 2010Closed
Citation 1, item 4a
29 CFR 1910.134(h)(1) · Respiratory protection
Serious$1,050$750Jun 10, 2010Closed
Citation 1, item 4b
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Jun 10, 2010Closed
Citation 1, item 5
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$2,450$1,800Jun 10, 2010Closed
Citation 1, item 6a
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$1,750$1,300Jun 10, 2010Closed
Citation 1, item 6b
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$0$0Jun 10, 2010Closed
Citation 1, item 6c
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Jun 10, 2010Closed
Citation 1, item 6d
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Jun 10, 2010Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$350$260Jun 10, 2010Closed
Citation 2, item 2
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$175$175Jun 10, 2010Closed
Citation 2, item 3
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$175$175Jun 10, 2010Closed
Citation 2, item 4
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$175$175Jun 10, 2010Closed
Citation 2, item 5
29 CFR 3000327 B 1
Other-than-serious$2,100$1,575Jun 10, 2010Closed
Citation 2, item 6
29 CFR 9000602
Other-than-serious$350$260Jun 10, 2010Closed
Citation 2, item 7
29 CFR 90007
Other-than-serious$350$260Jun 10, 2010Closed

Inspection 310705330 OPENED JAN 19, 2007Closed

Referral · Partial · Safety · 102 employees at the site · Closed Mar 14, 2007

920 Richmond Street, Jackson, TN 38301 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$1,400$1,400Feb 22, 2007Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$350$350Feb 22, 2007Closed
Citation 2, item 2a
29 CFR 1910.37(a)(3) · Exit routes
Other-than-serious$175$175Feb 22, 2007Closed
Citation 2, item 2b
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Feb 22, 2007Closed
Citation 2, item 3
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 22, 2007Closed
Citation 2, item 4
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 22, 2007Closed

Inspection 310704820 OPENED JAN 11, 2007Closed

Complaint · Partial · Health · 102 employees at the site · Closed Mar 12, 2007

920 Richmond Street, Jackson, TN 38301 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(3)

(3) Floors. The floor surface of a spray booth and operator's working area, if combustible, shall be covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues.

29 CFR 1910.107(b)(6)

(6) Frontal area. Each spray booth having a frontal area larger than 9 square feet shall have a metal deflector or curtain not less than 2 1/2 inches deep installed at the upper outer edge of the booth over the opening.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment