OSHA SearchOSHA records by employer

Smith Refrigeration Inc: OSHA inspections and violations

Wallace, South Carolina · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
2citation items
$300current penalties
Sep 16, 2015last inspection

OSHA has inspected Smith Refrigeration Inc once in South Carolina.

The inspection began on Sep 16, 2015 as a planned inspection, in Wallace.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $300 and still stand at $300.

Ground-fault protection on job sites comes up most often in these citations: 2 items under 1926.404.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Smith Refrigeration Inc averages $300 (1 cited inspection).

Smith Refrigeration Inc: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

43employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Smith Refrigeration Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340933365 OPENED SEP 16, 2015Closed

Planned · Complete · Safety · 14 employees at the site · Closed Nov 30, 2015

3643 Highway 9 West, Wallace, SC 29596 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$300$300Oct 28, 2015Final
Citation 1, item 2b
29 CFR 1926.404(f)(7)(iv)(c)(2) · Ground-fault protection on job sites
Serious$0$0Oct 28, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(7)(iv)(c)(2)

(C) If the equipment is one of the types listed in paragraphs (f)(7)(iv)(C)(1) through (f)(7)(iv)(C)(5) of this section. However, even though the equipment may be one of these types, it need not be grounded if it is exempted by paragraph (f)(7)(iv)(C)(6).

Other plumbing, heating, and air-conditioning contractors employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.