OSHA SearchOSHA records by employer

Soles Enterprises, LLC: OSHA inspections and violations

Fairmont, West Virginia · Primary Battery Manufacturing · NAICS 335912

1inspections
28citation items
$19,250current penalties
Mar 18, 2015last inspection

OSHA inspectors have visited Soles Enterprises, LLC in West Virginia one time.

It opened on Mar 18, 2015 as a planned inspection, in Fairmont.

In all, OSHA issued 28 citation items: 28 serious.

The proposed penalties came to $38,500; today they stand at $19,250, 50% less.

The rule cited most here is 1910.1018 (inorganic arsenic), 14 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Soles Enterprises, LLC averages $19,250 across 1 cited inspection.

Soles Enterprises, LLC also files yearly injury logs with OSHA, summarized below.

Soles Enterprises, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

West Virginia · latest 90 days of OSHA records

28employers cited

Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in West Virginia

Checking a subcontractor, a client or your own company? Watch Soles Enterprises, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340478361 OPENED MAR 18, 2015Closed

Planned · Partial · Health · 4 employees at the site · Closed Jul 31, 2017

225 Holbert Road, Fairmont, WV 26554 · Primary Battery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$3,500$1,750Jul 6, 2015Final
Citation 1, item 1b
29 CFR 1910.107(b)(2) · Spray painting and finishing
Serious$0$0Jul 6, 2015Final
Citation 1, item 2a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$3,500$1,750Jul 6, 2015Final
Citation 1, item 2b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Jul 6, 2015Final
Citation 1, item 2c
29 CFR 1910.134(k)(3) · Respiratory protection
Serious$0$0Jul 6, 2015Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,500$1,750Jul 6, 2015Final
Citation 1, item 4a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$3,500$1,750Jul 6, 2015Final
Citation 1, item 4b
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Jul 6, 2015Final
Citation 1, item 5
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$2,800$1,400Jul 6, 2015Final
Citation 1, item 6a
29 CFR 1910.1018(c) · Inorganic arsenic
Serious$3,500$1,750Jul 6, 2015Final
Citation 1, item 6b
29 CFR 1910.1018(e)(2) · Inorganic arsenic
Serious$0$0Jul 6, 2015Final
Citation 1, item 6c
29 CFR 1910.1018(f)(1) · Inorganic arsenic
Serious$0$0Jul 6, 2015Final
Citation 1, item 7a
29 CFR 1910.1018(g)(1)(i) · Inorganic arsenic
Serious$3,500$1,750Jul 6, 2015Final
Citation 1, item 7b
29 CFR 1910.1018(g)(2)(i) · Inorganic arsenic
Serious$0$0Jul 6, 2015Final
Citation 1, item 8a
29 CFR 1910.1018(j)(2)(vii)(a) · Inorganic arsenic
Serious$3,500$1,750Jul 6, 2015Final
Citation 1, item 8b
29 CFR 1910.1018(p)(1)(iii) · Inorganic arsenic
Serious$0$0Jul 6, 2015Final
Citation 1, item 8c
29 CFR 1910.1018(p)(2)(i) · Inorganic arsenic
Serious$0$0Jul 6, 2015Final
Citation 1, item 9a
29 CFR 1910.1018(k)(4) · Inorganic arsenic
Serious$3,500$1,750Jul 6, 2015Final
Citation 1, item 9b
29 CFR 1910.1018(o)(1)(i) · Inorganic arsenic
Serious$0$0Jul 6, 2015Final
Citation 1, item 9c
29 CFR 1910.1018(m)(2)(i) · Inorganic arsenic
Serious$0$0Jul 6, 2015Final
Citation 1, item 9d
29 CFR 1910.1018(m)(3)(i) · Inorganic arsenic
Serious$0$0Jul 6, 2015Final
Citation 1, item 10a
29 CFR 1910.1018(n)(1)(i)(a) · Inorganic arsenic
Serious$3,500$1,750Jul 6, 2015Final
Citation 1, item 10b
29 CFR 1910.1018(n)(3)(i) · Inorganic arsenic
Serious$0$0Jul 6, 2015Final
Citation 1, item 11a
29 CFR 1910.1025(d)(4)(i) · Lead in general industry
Serious$2,100$1,050Jul 6, 2015Final
Citation 1, item 11b
29 CFR 1910.1025(d)(2) · Lead in general industry
Serious$0$0Jul 6, 2015Final
Citation 1, item 12a
29 CFR 1910.1025(h)(1) · Lead in general industry
Serious$2,100$1,050Jul 6, 2015Final
Citation 1, item 12b
29 CFR 1910.1025(j)(1)(i) · Lead in general industry
Serious$0$0Jul 6, 2015Final
Citation 1, item 12c
29 CFR 1910.1025(l)(1)(i) · Lead in general industry
Serious$0$0Jul 6, 2015Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Fairmont site logged 0 recordable injuries or illnesses among about 50 workers: 0.0 per 100 full-time workers, against a median of 1.5 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Soles Enterprises LLC
Fairmont · 2024
50 000.01.5
Soles Electric
Fairmont · 2022
48 214.51.5
Soles Electric Company Fairmont
Fairmont · 2018
47 408.41.5

Included with any plan: 5 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1018 · Inorganic arsenic

29 CFR 1910.1018(c)

(c) Permissible exposure limit. The employer shall assure that no employee is exposed to inorganic arsenic at concentrations greater than 10 micrograms per cubic meter of air (10 µg/m 3), averaged over any 8-hour period.

29 CFR 1910.1018(e)(2)

(2) Initial monitoring. Each employer who has a workplace or work operation covered by this standard shall monitor each such workplace and work operation to accurately determine the airborne concentration of inorganic arsenic to which employees may be exposed.

29 CFR 1910.1018(f)(1)

(f) Regulated area—(1) Establishment. The employer shall establish regulated areas where worker exposures to inorganic arsenic, without regard to the use of respirators, are in excess of the permissible limit.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.304 · Grounding and circuit protection

Other primary battery manufacturing employers in West Virginia

Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.