Spirit Fabs, Inc.: OSHA inspections and violations
Green Bay, Wisconsin · Fabricated Structural Metal Manufacturing · NAICS 332312
7inspections
20citation items
$9,027current penalties
Jun 15, 2017last inspection
OSHA has inspected Spirit Fabs, Inc. 7 times in Wisconsin since 2001.
The latest one began on Jun 15, 2017 after a complaint, in Green Bay.
Those inspections ended with 20 citation items: 11 serious and 9 other-than-serious.
Penalties were first proposed at $16,286 and now stand at $9,027, 45% lower after settlements or reviews.
Respiratory protection comes up most often in these citations: 7 items under 1910.134.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Spirit Fabs, Inc. averages $8,437 (1 cited inspection).
Spirit Fabs, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Wisconsin · latest 90 days of OSHA records
216employers cited
Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Wrightstown site logged 2 recordable injuries or illnesses among about 65 workers: 3.0 per 100 full-time workers, against a median of 2.4 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Spirit Fabs, Inc.
Wrightstown · 2025
65
2
0
3.0
2.4
Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
An employee was rolling a steel beam with an overhead crane and a plate clamp. The clamp slipped and the beam fell, crushing the employee's left middle fingertip. The tip was surgically removed at the first knuckle.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.107(d)(2)
(2) General. All spraying areas shall be provided with mechanical ventilation adequate to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life is not endangered. Mechanical ventilation shall be kept in operation at all times while spraying operations are being conducted and for a sufficient time thereafter to allow vapors from drying coated articles and drying finishing material residue to be exhausted.
Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.