OSHA SearchOSHA records by employer

ST Paul Beverage Solutions LLC: OSHA inspections and violations

Saint Paul, Minnesota · Fluid Milk Manufacturing · NAICS 311511

3inspections
10citation items
$15,270current penalties
Dec 2, 2025last inspection

Since 2022, OSHA inspectors have visited ST Paul Beverage Solutions LLC in Minnesota 3 times.

The most recent inspection opened on Dec 2, 2025 as a planned inspection, in Saint Paul.

In all, OSHA issued 10 citation items: 8 serious and 2 other-than-serious.

The proposed penalties came to $24,650; today they stand at $15,270, 38% less.

The rule cited most here is 1910.119 (process safety management), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,875 penalty. ST Paul Beverage Solutions LLC averages $5,090 across 3 cited inspections.

ST Paul Beverage Solutions LLC: OSHA citation items per year, 2022 to 2025
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

369employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch ST Paul Beverage Solutions LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348622887 OPENED DEC 2, 2025Closed

Planned · Complete · Safety · 284 employees at the site · Closed Jul 6, 2026

2080 Rice St, Saint Paul, MN 55113 · Fluid Milk Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.176(c) · Material storage and aisles
Other-than-serious$600$600Dec 9, 2025Final
Citation 1, item 2
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$600$600Dec 9, 2025Final

Inspection 346216534 OPENED SEP 13, 2022Closed

Planned · Complete · Health · 260 employees at the site · Closed Sep 19, 2023

2080 Rice St, Saint Paul, MN 55113 · Fluid Milk Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.119(d)(3)(i)(b) · Process safety management
Serious$4,900$2,940Feb 27, 2023Final
Citation 1, item 2
29 CFR 1910.119(g)(2) · Process safety management
Serious$2,100$1,260Feb 27, 2023Final
Citation 1, item 3
29 CFR 1910.119(n) · Process safety management
Serious$4,900$2,940Feb 27, 2023Final
Citation 1, item 4
29 CFR 1910.119(o)(4) · Process safety management
Serious$4,900$2,940Feb 27, 2023Final
Citation 1, item 5
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$1,750$1,050Feb 27, 2023Final

Inspection 346282627 OPENED SEP 13, 2022Closed

Planned · Complete · Safety · 260 employees at the site · Closed Sep 14, 2023

2080 Rice St, Saint Paul, MN 55113 · Fluid Milk Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$1,750$1,050Feb 27, 2023Final
Citation 1, item 2
29 CFR 1910.106(e)(2)(ii)(b)(2) · Flammable liquids
Serious$1,400$840Feb 27, 2023Final
Citation 1, item 3
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$1,750$1,050Feb 27, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ii)(b)(2)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.119 · Process safety management

29 CFR 1910.119(d)(3)(i)(b)

(B) Piping and instrument diagrams (P&ID's);

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.28 · Fall protection in general industry

Other fluid milk manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.