STK Electronics, Inc.: OSHA inspections and violations

Cazenovia, New York · Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing · NAICS 334416

2inspections
8citation items
$4,883current penalties
Apr 25, 2019last inspection

STK Electronics, Inc. has 2 OSHA inspections on record in New York, the first in 1986.

OSHA's last visit started on Apr 25, 2019 as a planned inspection, in Cazenovia.

Across those inspections OSHA issued 8 citation items: 5 serious and 3 other-than-serious.

OSHA proposed $8,039 in penalties. After settlements and reviews the total is $4,883, down 39%.

Most often, OSHA cited 1910.106, flammable liquids (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. STK Electronics, Inc. averages $4,733 over 1 cited inspection in that time.

STK Electronics, Inc.: OSHA citation items per year, 1986 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites STK Electronics, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343957890 OPENED APR 25, 2019Closed

Planned · Complete · Health · 30 employees at the site · Closed Jul 29, 2020

2747 Route 20 East, Cazenovia, NY 13035 · Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,508$2,705Sep 18, 2019Final
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$3,381$2,029Sep 18, 2019Final
Citation 2, item 1
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$0$0Sep 18, 2019Final

Inspection 100162783 OPENED JUN 27, 1986Closed

Complaint · Partial · Health · 82 employees at the site · Closed Jan 5, 1987

John Trush Jr. Blvd., Cazenovia, NY 13035 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$150$150Oct 29, 1986Closed
Citation 1, item 1b
29 CFR 1910.106(d)(4)(iii) · Flammable liquids
Serious$0$0Oct 29, 1986Closed
Citation 1, item 1c
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Oct 29, 1986Closed
Citation 2, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 29, 1986Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 29, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iii)

(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.212 · Machine guarding

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.304 · Grounding and circuit protection

Other capacitor, resistor, coil, transformer, and other inductor manufacturing employers in New York

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.