Swaim Ornamental Iron Works, Inc.: OSHA inspections and violations

Winston Salem, North Carolina · Ornamental and Architectural Metal Work Manufacturing · NAICS 332323

4inspections
75citation items
$3,775current penalties
Jan 20, 2016last inspection

OSHA has inspected Swaim Ornamental Iron Works, Inc. 4 times in North Carolina since 2003.

The latest one began on Jan 20, 2016 as a planned inspection, in Winston Salem.

Those inspections ended with 75 citation items: 34 serious and 41 other-than-serious.

Penalties were first proposed at $4,500 and now stand at $3,775, 16% lower after settlements or reviews.

Hazard communication comes up most often in these citations: 9 items under 1910.1200.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Swaim Ornamental Iron Works, Inc. averages $2,100 (1 cited inspection).

Swaim Ornamental Iron Works, Inc. also files yearly injury logs with OSHA, summarized below.

Swaim Ornamental Iron Works, Inc.: OSHA citation items per year, 2003 to 2016
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Swaim Ornamental Iron Works, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341188571 OPENED JAN 20, 2016Closed

Planned · Complete · Health · 22 employees at the site · Closed Mar 28, 2016

2570 Landmark Drive, Winston Salem, NC 27103 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$600$600Feb 9, 2016Final
Citation 1, item 1b
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Serious$0$0Feb 9, 2016Final
Citation 1, item 1c
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Feb 9, 2016Final
Citation 1, item 2a
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$600$600Feb 9, 2016Final
Citation 1, item 2b
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$0$0Feb 9, 2016Final
Citation 1, item 2c
29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks
Serious$0$0Feb 9, 2016Final
Citation 1, item 3a
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$300$300Feb 9, 2016Final
Citation 1, item 3b
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Serious$0$0Feb 9, 2016Final
Citation 1, item 4a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$300$300Feb 9, 2016Final
Citation 1, item 4b
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0Feb 9, 2016Final
Citation 1, item 4c
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Serious$0$0Feb 9, 2016Final
Citation 1, item 5a
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$300$300Feb 9, 2016Final
Citation 1, item 5b
29 CFR 1910.1200(j)(1) · Hazard communication
Serious$0$0Feb 9, 2016Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Feb 9, 2016Final

Inspection 315434043 OPENED MAR 1, 2011Closed

Planned · Complete · Safety · 18 employees at the site · Closed Apr 12, 2011

2570 Landmark Drive, Winston-salem, NC 27103 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$300$300Mar 22, 2011Closed
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Mar 22, 2011Closed
Citation 1, item 1c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Mar 22, 2011Closed
Citation 1, item 1d
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Serious$0$0Mar 22, 2011Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$300$300Mar 22, 2011Closed
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Mar 22, 2011Closed
Citation 2, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 22, 2011Closed
Citation 2, item 3
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 22, 2011Closed
Citation 2, item 4a
29 CFR 1910.254(d)(8) · Arc welding and cutting
Other-than-serious$0$0Mar 22, 2011Closed
Citation 2, item 4b
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Other-than-serious$0$0Mar 22, 2011Closed
Citation 2, item 5
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Mar 22, 2011Closed
Citation 2, item 6
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Mar 22, 2011Closed

Inspection 310399746 OPENED JAN 23, 2007Closed

Planned · Complete · Health · 23 employees at the site · Closed Feb 21, 2007

2570 Landmark Drive, Winston-salem, NC 27103 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$100$100Jan 31, 2007Closed
Citation 1, item 2a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$100$100Jan 31, 2007Closed
Citation 1, item 2b
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Jan 31, 2007Closed
Citation 1, item 2c
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Jan 31, 2007Closed
Citation 1, item 2d
29 CFR 1910.305(g)(1)(iiia) · Electrical wiring methods
Serious$0$0Jan 31, 2007Closed
Citation 1, item 2e
29 CFR 1910.305(g)(1)(iiic) · Electrical wiring methods
Serious$0$0Jan 31, 2007Closed
Citation 1, item 2f
29 CFR 1910.305(g)(1)(iiid) · Electrical wiring methods
Serious$0$0Jan 31, 2007Closed
Citation 1, item 2g
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Jan 31, 2007Closed
Citation 2, item 1
29 CFR 1910.37(b)(3) · Exit routes
Other-than-serious$0$0Jan 31, 2007Closed
Citation 2, item 2a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jan 31, 2007Closed
Citation 2, item 2b
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jan 31, 2007Closed
Citation 2, item 3
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Jan 31, 2007Closed

Inspection 306499617 OPENED MAY 29, 2003Closed

Planned · Complete · Safety · 19 employees at the site · Closed Sep 2, 2003

2570 Landmark Drive, Winston Salem, NC 27103 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7F0102
Serious$350$200Jun 25, 2003Closed
Citation 1, item 2a
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$250$135Jun 25, 2003Closed
Citation 1, item 2b
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Serious$0$0Jun 25, 2003Closed
Citation 1, item 3
29 CFR 1910.107(e)(9) · Spray painting and finishing
Serious$250$135Jun 25, 2003Closed
Citation 1, item 4
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$250$135Jun 25, 2003Closed
Citation 1, item 5
29 CFR 1910.252(b)(3) · Welding fire safety
Serious$250$135Jun 25, 2003Closed
Citation 1, item 6a
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$250$135Jun 25, 2003Closed
Citation 1, item 6b
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Jun 25, 2003Closed
Citation 2, item 2a
29 CFR 1910.22(b)(1) · General requirements
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 2b
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 3
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 4
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 5
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 6
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 7
29 CFR 1910.145(c)(2)(i) · Specifications for accident prevention signs and tags
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 8a
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 8b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 9
29 CFR 1910.151(b) · First aid and eyewash
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 10a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 10b
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 10c
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 11a
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 11b
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 13a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 13b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 14
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 16
29 CFR 1910.254(b)(4)(iv) · Arc welding and cutting
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 17a
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 17b
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 17c
29 CFR 1910.303(g)(2)(id) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 18a
29 CFR 1910.304(e)(1)(iv) · Grounding and circuit protection
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 19a
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 19b
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 21a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 21b
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 21c
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Jun 25, 2003Closed
Citation 2, item 21d
29 CFR 1910.1200(h)(1)(i) · Hazard communication
Other-than-serious$0$0Jun 25, 2003Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Winston Salem site logged 1 recordable injury or illness among about 25 workers: 3.3 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Swaim Ornamental Iron Works Inc
Winston Salem · 2025
25 103.33.6

Included with any plan: 1 more yearly log from these sites, back to 2024, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.106(e)(9)(iii)

(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(e)(2)

(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes