Thermal Care, Inc.: OSHA inspections and violations
Niles, Illinois · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · NAICS 333415
8inspections
31citation items
$33,290current penalties
Jul 19, 2018last inspection
OSHA has inspected Thermal Care, Inc. 8 times in Illinois since 1983.
The latest one began on Jul 19, 2018 after a complaint, in Niles.
Those inspections ended with 31 citation items: 19 serious and 12 other-than-serious.
Penalties were first proposed at $59,877 and now stand at $33,290, 44% lower after settlements or reviews.
Respiratory protection comes up most often in these citations: 8 items under 1910.134.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Thermal Care, Inc. averages $10,000 (1 cited inspection).
1 inspection on this page followed a fatal incident.
Thermal Care, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Illinois · latest 90 days of OSHA records
416employers cited
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
Planned · Partial · Safety · 87 employees at the site · Closed Feb 9, 2010
7720 N. Lehigh Ave., Niles, IL 60714 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
Follow-up · Partial · Health · 125 employees at the site · Closed Oct 29, 2003
7720 N. Lehigh, Niles, IL 60714 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 307025429 OPENED SEP 8, 2003Closed
Follow-up · No inspection · Health · 125 employees at the site · Closed Sep 8, 2003
7720 N. Lehigh, Niles, IL 60714 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 307025155 OPENED SEP 2, 2003Closed
Follow-up · Partial · Safety · 123 employees at the site · Closed Sep 2, 2003
7720 N. Lehigh, Niles, IL 60714 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Inspection 305974073 OPENED JAN 7, 2003Closed
Referral · Partial · Health · 125 employees at the site · Closed Apr 29, 2003
7720 N. Lehigh, Niles, IL 60714 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
Accident · Partial · Safety · 125 employees at the site · Closed Jul 8, 2003
7720 N. Lehigh, Niles, IL 60714 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Dec 6, 2002 (fatal): Employee found dead in water reservoir tank being cleaned
On December 6, 2002, Employee #1, a chiller assembler, was found dead inside a w ater tank reservoir he was cleaning. Employee #1's normal shift begins at 7:00 a .m. Employee #1's time card did not show him leaving work the night before. His tools were found to have been left out and his automobile was still in the parki ng lot. The supervisor went looking for Employee #1 and found him around 6:00 to 6:30 a.m. in the water reservoir. Employee #1 was inside the water reservoir, a n open tank that was being manufactured. Employee #1 had been grinding and clean ing off the tank. At the time of the accident, Employee #1 was cleaning the tank with LPS, a heavy-duty degreaser. A can of the LPS was underneath Employee #1. The supervisor called for someone to call Emergency Services and entered the tan k and found Employee #1 dead.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2022, the Niles site logged 6 recordable injuries or illnesses among about 121 workers: 5.3 per 100 full-time workers, against a median of 2.4 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Thermal Care Inc.
Niles · 2022
121
6
0
5.3
2.4
Niles site
Niles · 2017
122
2
1
1.6
2.1
Included with any plan: 3 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Jul 2, 2025, Niles: Amputation · avulsions, enucleations without bone loss · thumb(s)
An employee was opening a manual gate on the property. The gate reached the end of the track and fell off the rail. The employee then went to lift the panel back onto the track and the tip of their left thumb was pinched between the rail and the roller resulting in amputation of soft tissue from the top of the thumb.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.
(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.