OSHA SearchOSHA records by employer

Trudeau Electric Inc: OSHA inspections and violations

Yemassee, South Carolina · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
3citation items
$1,750current penalties
Mar 29, 2017last inspection

Trudeau Electric Inc has 2 OSHA inspections on record in South Carolina, the first in 2016.

OSHA's last visit started on Mar 29, 2017 to follow up on an earlier case, in Yemassee.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $5,000 in penalties. After settlements and reviews the total is $1,750, down 65%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Trudeau Electric Inc averages $1,750 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Trudeau Electric Inc: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

43employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Trudeau Electric Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342254828 OPENED MAR 29, 2017Closed

Follow-up · Partial · Safety · 7 employees at the site · Closed May 4, 2017

108 River Rd, Yemassee, SC 29945 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341642833 OPENED JUL 22, 2016Closed

Fatality or catastrophe · Partial · Safety · 2 employees at the site · Closed May 4, 2017

108 River Rd, Yemassee, SC 29945 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 21, 2016 (fatal): Employee falls and is killed

At 11:25 a.m. on June 22, 2016, a crew of two electrical contractor employees was relocating junction boxes for a large manufacturing facility. They were relocating the junction box because it was in the way of a new indoor crane being installed. Employee #1 had one year on-the-job experience and no school training in electric work. The electrical foreman had electrical training from the military. The new large junction box was located approximately 19 feet from ground level and attached to a smaller 4 by 4 by 2.5 (inches) junction box that was approximately 17 feet 4 inches from ground level. There was an I-beam going across the facility just below the junction boxes at 14 feet 8 inches. The power was not permanently shut off from the panel box that powered the junction boxes. The panel box was 277volts/480 volts. To gain access to the junction boxes, the employer provided employees with 10 feet 1 inch of masonry framing scaffold. Employee #1 climbed up the masonry scaffold frame then used the cross braces to step up on the I-beam. Employee #1 used an electrical tester; tested each wire to determine if it was live or not. Once Employee #1 found the wire and determined if it was live, Employee #1 would relay to the Electrical Foreman on the ground to turn off the power. The panel box was not labeled, therefore, the Electrical Foreman would have to go switch by switch until the tester indicated the wire was not live. While working on the junction box, Employee #1 was sitting on the I-beam, lost his balance and fell. While falling, Employee #1 struck the cross braces with his legs and struck his head on the electrical panel before ultimately falling to the concrete floor and striking his head. Employee #1 died from a fracture of the neck due to a fall from a height. neck due to a fall from a height.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3
29 CFR 1926.501(b)(15) · Fall protection in construction
Serious$1,500$750Jan 19, 2017Final
Citation 1, item 4a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,500$1,000Jan 19, 2017Final
Citation 1, item 4b
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$2,000$0Jan 19, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(15)

(15) Walking/working surfaces not otherwise addressed. Except as provided in § 1926.500(a)(2) or in § 1926.501 (b)(1) through (b)(14), each employee on a walking/working surface 6 feet (1.8 m) or more above lower levels shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system.

Other electrical contractors and other wiring installation contractors employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.