Easley, South Carolina · Fabricated Structural Metal Manufacturing · NAICS 332312
3inspections
11citation items
$11,924current penalties
Jul 3, 2019last inspection
Since 2013, OSHA inspectors have visited Vci-SC Inc in South Carolina 3 times.
The most recent inspection opened on Jul 3, 2019 as a planned inspection, in Easley.
In all, OSHA issued 11 citation items: 9 serious and 2 other-than-serious.
The proposed penalties came to $21,925; today they stand at $11,924, 46% less.
The rule cited most here is 1910.107 (spray painting and finishing), 5 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Vci-SC Inc averages $7,999 across 1 cited inspection.
Vci-SC Inc also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
South Carolina · latest 90 days of OSHA records
43employers cited
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2020, the Easley site logged 6 recordable injuries or illnesses among about 44 workers: 13.3 per 100 full-time workers, against a median of 2.4 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Vci-SC
Easley · 2020
44
6
0
13.3
2.4
Included with any plan: 1 more yearly log from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(c)(6)
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.107(f)(3)
(3) Cleaning of heads. Sprinklers protecting spraying areas shall be kept as free from deposits as practical by cleaning daily if necessary. (See also paragraph (g) of this section.)
Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.