OSHA SearchOSHA records by employer

Vogel Display Corporation: OSHA inspections and violations

Becker, Minnesota · Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing · NAICS 335122

3inspections
7citation items
$2,800current penalties
May 8, 2025last inspection

Since 1995, OSHA inspectors have visited Vogel Display Corporation in Minnesota 3 times.

The most recent inspection opened on May 8, 2025 after a complaint, in Becker.

In all, OSHA issued 7 citation items: 5 serious and 2 other-than-serious.

The penalties, $2,800 in total, stand where OSHA first set them.

The rule cited most here is 1910.219 (belts, pulleys and power-transmission parts), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Vogel Display Corporation averages $200 across 1 cited inspection.

Vogel Display Corporation: OSHA citation items per year, 1995 to 2025
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

369employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Vogel Display Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348242900 OPENED MAY 8, 2025Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Jul 14, 2025

13982 Industry Ave, Becker, MN 55308 · Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$200$200May 21, 2025Final

Inspection 126561737 OPENED DEC 5, 1995Closed

Complaint · Partial · Health · 35 employees at the site · Closed May 22, 1996

13982 Industry Ave, Becker, MN 55308 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Jan 18, 1996Closed

Inspection 126571363 OPENED DEC 5, 1995Closed

Complaint · Complete · Safety · 30 employees at the site · Closed May 28, 1996

13982 Industry Ave, Becker, MN 55308 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$0$0Jan 18, 1996Closed
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$600$600Jan 18, 1996Closed
Citation 1, item 3
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$600$600Jan 18, 1996Closed
Citation 1, item 4
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$800$800Jan 18, 1996Closed
Citation 1, item 5 Serious$600$600Jan 18, 1996Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(d)(1)

(d) Pulleys—(1) Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.

29 CFR 1910.219(f)(3)

(3) Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets.

29 CFR 1910.332 · Training

29 CFR 5205.700

Other commercial, industrial, and institutional electric lighting fixture manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.