Inspection 345471486 OPENED AUG 11, 2021Closed
137 Hanover Pike, Hampstead, MD 21074 · Machine Shops · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 1987, OSHA inspectors have visited Western Industrial Machining, Inc. in Maryland 10 times.
The most recent inspection opened on Aug 11, 2021 to follow up on an earlier case, in Hampstead.
In all, OSHA issued 101 citation items: 52 serious and 49 other-than-serious.
The proposed penalties came to $51,912; today they stand at $31,128, 40% less.
The rule cited most here is 1910.1200 (hazard communication), 10 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Western Industrial Machining, Inc. averages $4,809 across 3 cited inspections.
Maryland · latest 90 days of OSHA records
183employers cited
Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Maryland
Checking a subcontractor, a client or your own company? Watch Western Industrial Machining, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company137 Hanover Pike, Hampstead, MD 21074 · Machine Shops · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
137 Hanover Pike, Hampstead, MD 21074 · Machine Shops · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $1,650 | $941 | Jan 2, 2020 | Final |
| Citation 1, item 1b 29 CFR 1910.1200(f)(6)(ii) · Hazard communication |
Serious | $0 | $0 | Jan 2, 2020 | Final |
| Citation 1, item 1c 29 CFR 1910.1200(g)(1) · Hazard communication |
Serious | $0 | $0 | Jan 2, 2020 | Final |
| Citation 1, item 1d 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Jan 2, 2020 | Final |
| Citation 2, item 1 29 CFR 1910.106(d)(2)(i) · Flammable liquids |
Other-than-serious | $0 | $0 | Jan 2, 2020 | Final |
| Citation 2, item 2 29 CFR 1910.138(a) · Gloves and hand protection |
Other-than-serious | $0 | $0 | Jan 2, 2020 | Final |
| Citation 2, item 3 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 2, 2020 | Final |
| Citation 2, item 4 29 CFR 1910.1200(j)(2)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 2, 2020 | Final |
137 Hanover Pike, Hampstead, MD 21074 · Machine Shops · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $1,925 | $1,345 | Feb 18, 2020 | Final |
| Citation 1, item 1b 29 CFR 1910.147(c)(5)(i) · Lockout/tagout |
Serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 1, item 1c 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 1, item 1d 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 1, item 2a 29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks |
Serious | $1,925 | $1,345 | Feb 18, 2020 | Final |
| Citation 1, item 2b 29 CFR 1910.178(a)(5) · Forklifts and other powered industrial trucks |
Serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 1, item 3 29 CFR 1910.184(i)(9)(iii) · Slings |
Serious | $1,925 | $1,345 | Feb 18, 2020 | Final |
| Citation 1, item 4a 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $2,000 | $1,400 | Feb 18, 2020 | Final |
| Citation 1, item 4b 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 1, item 5 29 CFR 1910.242(b) · Hand and power tools |
Serious | $2,200 | $1,540 | Feb 18, 2020 | Final |
| Citation 1, item 6a 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Serious | $1,925 | $1,345 | Feb 18, 2020 | Final |
| Citation 1, item 6b 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 1, item 7 29 CFR 1910.304(g)(6)(vi)(c)(8) · Grounding and circuit protection |
Serious | $2,200 | $1,540 | Feb 18, 2020 | Final |
| Citation 1, item 8 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $2,200 | $1,320 | Feb 18, 2020 | Final |
| Citation 1, item 9 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $2,200 | $1,320 | Feb 18, 2020 | Final |
| Citation 2, item 1 29 CFR 1910.37(b)(2) · Exit routes |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 2 29 CFR 1910.37(b)(5) · Exit routes |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 3 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 4 29 CFR 1910.147(c)(7)(iv) · Lockout/tagout |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 5 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 6 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 7 29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 8 29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 9 29 CFR 1910.212(a)(2) · Machine guarding |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 10 29 CFR 1910.212(b) · Machine guarding |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 11 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 12 29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 13 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
| Citation 2, item 14 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Feb 18, 2020 | Final |
170 Airport Drive, Westminster, MD 21157 · Machine Shops · OSHA's record · Phone and website on Google Maps
Incident on Mar 1, 2017: Worker falls from ladder, incurs multiple fractures, and oth
At 8:00 a.m. on March 1, 2017, Employee #1, employed by a machine shop, was performing repair work. He was working from a stepladder in the closed position and making repairs to a bay door on a loading dock. He was trying to tighten the spring of the bay door when a tool he was using spun around and hit him in the face. Employee #1 fell from the ladder and landed on the side of a welding table. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for fractures to seven to eight ribs, a lacerated liver, a partially collapsed lung, abrasions to his torso, and a cut to his face.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 05-104(A) |
Serious | $1,625 | $812 | Apr 20, 2017 | Final |
| Citation 2, item 1 29 CFR 1904.32(a)(4) · Yearly injury summary |
Other-than-serious | $350 | $175 | Apr 20, 2017 | Final |
| Citation 2, item 2 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 20, 2017 | Final |
170 Airport Drive, Westminster, MD 21157 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.132(d)(1)(i) · Personal protective equipment, general requirements |
Serious | $1,750 | $500 | Jul 17, 2000 | Closed |
| Citation 1, item 1b 29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements |
Serious | $0 | $0 | Jul 17, 2000 | Closed |
| Citation 2, item 1a 29 CFR 1910.94(d)(9)(iii) · Ventilation |
Serious | $1,500 | $500 | Jul 17, 2000 | Closed |
| Citation 2, item 1b 29 CFR 1910.94(d)(9)(v) · Ventilation |
Serious | $0 | $0 | Jul 17, 2000 | Closed |
| Citation 3, item 1 29 CFR 1910.107(e)(4) · Spray painting and finishing |
Serious | $750 | $250 | Jul 17, 2000 | Closed |
| Citation 3, item 2 29 CFR 1910.107(g)(3) · Spray painting and finishing |
Serious | $1,000 | $250 | Jul 17, 2000 | Closed |
| Citation 4, item 1 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $1,500 | $200 | Jul 17, 2000 | Closed |
| Citation 5, item 1 29 CFR 1910.94(d)(9)(viii) · Ventilation |
Other-than-serious | $0 | $0 | Jul 17, 2000 | Closed |
| Citation 5, item 2 29 CFR 1910.107(b)(9) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Jul 17, 2000 | Closed |
| Citation 5, item 3 29 CFR 1910.107(g)(7) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Jul 17, 2000 | Closed |
| Citation 5, item 4 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Jul 17, 2000 | Closed |
| Citation 5, item 5 29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Jul 17, 2000 | Closed |
| Citation 5, item 6 29 CFR 1910.138(a) · Gloves and hand protection |
Other-than-serious | $0 | $0 | Jul 17, 2000 | Closed |
| Citation 5, item 7 29 CFR 1910.252(c)(6)(ii) · Welding fire safety |
Other-than-serious | $0 | $0 | Jul 17, 2000 | Closed |
170 Airport Drive, Westminster, MD 21157 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 50104 A |
Serious | $1,575 | $200 | Jul 18, 2000 | Closed |
| Citation 2, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $1,350 | $400 | Jul 18, 2000 | Closed |
| Citation 3, item 1 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $1,350 | $200 | Jul 18, 2000 | Closed |
| Citation 4, item 1 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $1,125 | $400 | Jul 18, 2000 | Closed |
| Citation 5, item 1 29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting |
Serious | $675 | $200 | Jul 18, 2000 | Closed |
| Citation 6, item 1 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $1,125 | $400 | Jul 18, 2000 | Closed |
| Citation 6, item 2 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $1,575 | $400 | Jul 18, 2000 | Closed |
| Citation 7, item 1a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $1,575 | $400 | Jul 18, 2000 | Closed |
| Citation 7, item 1b 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Jul 18, 2000 | Closed |
| Citation 7, item 1c 29 CFR 50405 B01 |
Serious | $0 | $0 | Jul 18, 2000 | Closed |
| Citation 7, item 1d 29 CFR 50406 A01 |
Serious | $0 | $0 | Jul 18, 2000 | Closed |
| Citation 8, item 1a | Serious | $787 | $250 | Jul 18, 2000 | Closed |
| Citation 8, item 1b | Serious | $0 | $0 | Jul 18, 2000 | Closed |
| Citation 9, item 1 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jul 18, 2000 | Closed |
| Citation 9, item 2 29 CFR 1910.304(e)(1)(vic) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jul 18, 2000 | Closed |
| Citation 9, item 3 29 CFR 1910.305(a)(2)(iiif) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jul 18, 2000 | Closed |
137 Hanover Pike, Hampstead, MD 21074 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
137 Hanover Pike, Hampstead, MD 21074 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Serious | $1,400 | $1,400 | May 16, 1995 | Closed |
| Citation 1, item 2 29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements |
Serious | $1,400 | $1,400 | May 16, 1995 | Closed |
| Citation 2, item 1 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $1,200 | $1,200 | May 16, 1995 | Closed |
| Citation 3, item 1 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $1,400 | $1,400 | May 16, 1995 | Closed |
| Citation 3, item 2 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Serious | $1,400 | $1,400 | May 16, 1995 | Closed |
| Citation 3, item 3 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $1,400 | $1,400 | May 16, 1995 | Closed |
| Citation 4, item 1 | Serious | $1,400 | $1,400 | May 16, 1995 | Closed |
| Citation 5, item 1 29 CFR 1910.22(d)(1) · General requirements |
Other-than-serious | $0 | $0 | May 16, 1995 | Closed |
| Citation 5, item 2 29 CFR 1910.37(k)(2) · Exit routes |
Other-than-serious | $0 | $0 | May 16, 1995 | Closed |
| Citation 5, item 3 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | May 16, 1995 | Closed |
| Citation 5, item 4 29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | May 16, 1995 | Closed |
| Citation 5, item 5 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | May 16, 1995 | Closed |
| Citation 5, item 6 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | May 16, 1995 | Closed |
| Citation 5, item 7 | Other-than-serious | $0 | $0 | May 16, 1995 | Closed |
137 Hanover Pike, Hampstead, MD 21074 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $450 | $450 | Sep 21, 1993 | Closed |
| Citation 2, item 1 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $750 | $750 | Sep 21, 1993 | Closed |
| Citation 2, item 2 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $750 | $750 | Sep 21, 1993 | Closed |
| Citation 3, item 1 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $600 | $600 | Sep 21, 1993 | Closed |
| Citation 3, item 2 29 CFR 1910.1200(h) · Hazard communication |
Serious | $0 | $0 | Sep 21, 1993 | Closed |
| Citation 3, item 3 29 CFR 50405 B03 |
Other-than-serious | $0 | $0 | Sep 21, 1993 | Closed |
| Citation 3, item 4 29 CFR 50406 A01 |
Other-than-serious | $0 | $0 | Sep 21, 1993 | Closed |
| Citation 4, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Other-than-serious | $0 | $0 | Sep 21, 1993 | Closed |
| Citation 4, item 2 | Other-than-serious | $0 | $0 | Sep 21, 1993 | Closed |
137 Hanover Pike, Hampstead, MD 21074 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jul 20, 1987 | Closed |
| Citation 1, item 2 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jul 20, 1987 | Closed |
| Citation 1, item 3 29 CFR 890032 E B |
Other-than-serious | $0 | $0 | Jul 20, 1987 | Closed |
| Citation 1, item 4 29 CFR 890032 F A |
Other-than-serious | $0 | $0 | Jul 20, 1987 | Closed |
| Citation 1, item 5 29 CFR 890032 H A |
Other-than-serious | $0 | $0 | Jul 20, 1987 | Closed |
| Citation 1, item 6 29 CFR 890032 M B |
Other-than-serious | $0 | $0 | Jul 20, 1987 | Closed |
| Citation 1, item 7 | Other-than-serious | $0 | $0 | Jul 20, 1987 | Closed |
| Citation 1, item 8 | Other-than-serious | $0 | $0 | Jul 20, 1987 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(2)(i)
(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.
29 CFR 1910.107(b)(9)
(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.
Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.