Westfalia Technologies, Incorporated: OSHA inspections and violations
York, Pennsylvania · Conveyor and Conveying Equipment Manufacturing · NAICS 333922
3inspections
12citation items
$7,225current penalties
Nov 18, 2016last inspection
OSHA has inspected Westfalia Technologies, Incorporated 3 times in Pennsylvania since 1997.
The latest one began on Nov 18, 2016 on a referral, in York.
Those inspections ended with 12 citation items: 10 serious and 2 other-than-serious.
Penalties were first proposed at $12,658 and now stand at $7,225, 43% lower after settlements or reviews.
Belts, pulleys and power-transmission parts comes up most often in these citations: 2 items under 1910.219.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Westfalia Technologies, Incorporated averages $6,200 (1 cited inspection).
Westfalia Technologies, Incorporated also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Pennsylvania · latest 90 days of OSHA records
285employers cited
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Westfalia Technologies, Incorporated and get notified the morning OSHA posts a new citation for it.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the York site logged 10 recordable injuries or illnesses among about 218 workers: 4.7 per 100 full-time workers, against a median of 1.9 for its industry. Those cases cost 213 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Westfalia Technologies Inc.
York · 2025
218
10
3
4.7
1.9
Westfalia Technologies
York · 2024
228
5
1
2.3
1.9
Westfalaia Technologies, Inc.
York · 2022
155
4
1
2.5
1.9
Included with any plan: 2 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
(g) Training and education. (1) Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.
29 CFR 1910.178 · Forklifts and other powered industrial trucks
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.