Advance Industries Group: OSHA inspections and violations
Cleveland, Ohio · Fabricated Structural Metal Manufacturing · NAICS 332312
2inspections
11citation items
$7,700current penalties
Jan 21, 2016last inspection
Advance Industries Group has 2 OSHA inspections on record in Ohio, the first in 2016.
OSHA's last visit started on Jan 21, 2016 after a complaint, in Cleveland.
Across those inspections OSHA issued 11 citation items: 9 serious and 2 other-than-serious.
OSHA proposed $15,400 in penalties. After settlements and reviews the total is $7,700, down 50%.
Most often, OSHA cited 1910.147, lockout/tagout (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Advance Industries Group averages $3,850 over 2 cited inspections in that time.
Advance Industries Group also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Ohio · latest 90 days of OSHA records
265employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Cleveland site logged 0 recordable injuries or illnesses among about 27 workers: 0.0 per 100 full-time workers, against a median of 2.4 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Advance Industries Group, LLC.
Cleveland · 2025
27
0
0
0.0
2.4
Included with any plan: 8 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”
(6) Frontal area. Each spray booth having a frontal area larger than 9 square feet shall have a metal deflector or curtain not less than 2 1/2 inches deep installed at the upper outer edge of the booth over the opening.
29 CFR 1910.107(b)(9)
(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.
Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.