OSHA SearchOSHA records by employer

Commercial Millwork, Inc.: OSHA inspections and violations

Syracuse, New York · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

2inspections
10citation items
$5,976current penalties
Apr 26, 2017last inspection

OSHA has inspected Commercial Millwork, Inc. 2 times in New York since 2016.

The latest one began on Apr 26, 2017 to follow up on an earlier case, in Syracuse.

Those inspections ended with 10 citation items: 5 serious and 5 other-than-serious.

Penalties were first proposed at $5,976 and still stand at $5,976.

Forklifts and other powered industrial trucks comes up most often in these citations: 2 items under 1910.178.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Commercial Millwork, Inc. averages $5,976 (1 cited inspection).

Commercial Millwork, Inc.: OSHA citation items per year, 2016 to 2017
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Commercial Millwork, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342290384 OPENED APR 26, 2017Closed

Follow-up · No inspection · Health · 1 employee at the site · Closed May 2, 2017

221 West Division Street, Syracuse, NY 13204 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341872513 OPENED OCT 27, 2016Closed

Planned · Complete · Health · 3 employees at the site · Closed Nov 4, 2022

221 West Division Street, Syracuse, NY 13204 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$2,173$2,173Feb 10, 2017Final
Citation 1, item 1b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Feb 10, 2017Final
Citation 1, item 1c
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Feb 10, 2017Final
Citation 1, item 2
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$1,630$1,630Feb 10, 2017Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,173$2,173Feb 10, 2017Final
Citation 2, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Other-than-serious$0$0Feb 10, 2017Final
Citation 2, item 2a
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Feb 10, 2017Final
Citation 2, item 2b
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Feb 10, 2017Final
Citation 2, item 3a
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Feb 10, 2017Final
Citation 2, item 3b
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Feb 10, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(g)(2)

(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.22 · Walking-working surfaces

Other wood kitchen cabinet and countertop manufacturing employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.