Egger Steel Company has 19 OSHA inspections on record in South Dakota, the first in 1972.
OSHA's last visit started on Jan 27, 2026 as a planned inspection, in Sioux Falls, and the case has not closed yet.
Across those inspections OSHA issued 74 citation items: 23 serious and 51 other-than-serious.
OSHA proposed $24,238 in penalties. After settlements and reviews the total is $14,785, down 39%.
Most often, OSHA cited 1910.212, machine guarding (10 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Egger Steel Company averages $6,350 over 2 cited inspections in that time.
Egger Steel Company also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
South Dakota · latest 90 days of OSHA records
31employers cited
Get notified the morning OSHA posts each new citation in South Dakota: the employer, the site address, the rules broken and the penalty.
Incident on Dec 8, 2017: Employee's fingertip is amputated when caught in press brake
At 9:00 a.m. on December 8, 2017, Employee #1 was operating a press brake. As the employee was changing the dye, his finger became caught between the die and bed, amputating his right middle fingertip.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Sioux Falls site logged 7 recordable injuries or illnesses among about 42 workers: 14.3 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 60 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Egger Steel Company
Sioux Falls · 2025
42
7
2
14.3
3.6
Included with any plan: 8 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Dec 8, 2017, Sioux Falls: Amputation · amputations · fingertip(s)
An employee was changing a die on a press brake when the press brake was activated. The employee's finger was caught in the point of operation, partially amputating the fingertip.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(a) Table Z-1—(1) Substances with limits preceded by “C”—Ceiling Values. An employee's exposure to any substance in Table Z-1, the exposure limit of which is preceded by a “C”, shall at no time exceed the exposure limit given for that substance. If instantaneous monitoring is not feasible, then the ceiling shall be assessed as a 15-minute time weighted average exposure which shall not be exceeded at any time during the working day.
29 CFR 1910.1000(a)(2)
(2) Other substances—8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a “C”, shall not exceed the 8-hour Time Weighted Average given for that substance in any 8-hour work shift of a 40-hour work week.
29 CFR 1910.1000(e)
(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.
Alert subscribers get notified of each newly cited employer in South Dakota the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.