OSHA SearchOSHA records by employer

Fluitron, LLC: OSHA inspections and violations

Warminster, Pennsylvania · Metal Tank (Heavy Gauge) Manufacturing · NAICS 332420

6inspections
51citation items
$30,800current penalties
Mar 28, 2023last inspection

Fluitron, LLC has 6 OSHA inspections on record in Pennsylvania, the first in 1985.

OSHA's last visit started on Mar 28, 2023 after a complaint, in Ivyland.

Across those inspections OSHA issued 51 citation items: 40 serious and 11 other-than-serious.

OSHA proposed $35,150 in penalties. After settlements and reviews the total is $30,800, down 12%.

Most often, OSHA cited 1910.1200, hazard communication (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Fluitron, LLC averages $25,000 over 1 cited inspection in that time.

Fluitron, LLC also files yearly injury logs with OSHA, summarized below.

Fluitron, LLC: OSHA citation items per year, 1985 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Fluitron, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346594872 OPENED MAR 28, 2023Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Oct 2, 2023

30 Industrial Drive, Ivyland, PA 18974 · Metal Tank (Heavy Gauge) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(e)(2) · Exit route design
Serious$4,687$4,687Aug 24, 2023Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$6,250$6,250Aug 24, 2023Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Aug 24, 2023Final
Citation 1, item 2c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Aug 24, 2023Final
Citation 1, item 2d
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Aug 24, 2023Final
Citation 1, item 3
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$7,813$7,813Aug 24, 2023Final
Citation 1, item 4a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$6,250$6,250Aug 24, 2023Final
Citation 1, item 4b
29 CFR 1910.1200(g)(11) · Hazard communication
Serious$0$0Aug 24, 2023Final
Citation 1, item 4c
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Aug 24, 2023Final
Citation 2, item 1
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Aug 24, 2023Final

Inspection 303722698 OPENED OCT 25, 2001Closed

Complaint · Partial · Safety · 25 employees at the site · Closed Oct 26, 2001

30 Industrial Drive, Warminster, PA 18974 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303718753 OPENED FEB 21, 2001Closed

Complaint · Partial · Safety · 35 employees at the site · Closed Nov 16, 2001

30 Industrial Drive, Warminster, PA 18974 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Apr 2, 2001Closed
Citation 1, item 2
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Other-than-serious$0$0Apr 2, 2001Closed
Citation 1, item 3
29 CFR 1910.219(p)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Apr 2, 2001Closed

Inspection 123257974 OPENED AUG 3, 1994Closed

Planned · Complete · Health · 35 employees at the site · Closed Feb 7, 1995

30 Industrial Drive, Warminster, PA 18974 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$525$315Sep 15, 1994Closed
Citation 2, item 1
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Sep 15, 1994Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1)(ii) · Hazard communication
Other-than-serious$0$0Sep 15, 1994Closed
Citation 2, item 3a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Sep 15, 1994Closed
Citation 2, item 3b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Sep 15, 1994Closed

Inspection 123266660 OPENED AUG 2, 1994Closed

Planned · Complete · Safety · 35 employees at the site · Closed Nov 10, 1994

30 Industrial Drive, Warminster, PA 18974 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$525$295Aug 31, 1994Closed
Citation 1, item 2a
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$700$380Aug 31, 1994Closed
Citation 1, item 2b
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Serious$0$0Aug 31, 1994Closed
Citation 1, item 2c
29 CFR 1910.24(d) · Fixed industrial stairs
Serious$0$0Aug 31, 1994Closed
Citation 1, item 2d
29 CFR 1910.24(f) · Fixed industrial stairs
Serious$0$0Aug 31, 1994Closed
Citation 1, item 3a Serious$700$400Aug 31, 1994Closed
Citation 1, item 3b
29 CFR 1910.107(f)(4) · Spray painting and finishing
Serious$0$0Aug 31, 1994Closed
Citation 1, item 3c
29 CFR 1910.107(g)(3) · Spray painting and finishing
Serious$0$0Aug 31, 1994Closed
Citation 1, item 3d
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Aug 31, 1994Closed
Citation 1, item 4
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$700$400Aug 31, 1994Closed
Citation 1, item 5a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$700$400Aug 31, 1994Closed
Citation 1, item 5b
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Serious$0$0Aug 31, 1994Closed
Citation 1, item 5c Serious$0$0Aug 31, 1994Closed
Citation 1, item 5d
29 CFR 1910.333(b)(2)(i) · Working near live electrical parts
Serious$0$0Aug 31, 1994Closed
Citation 1, item 5e
29 CFR 1910.334(c)(1) · Using electrical equipment
Serious$0$0Aug 31, 1994Closed
Citation 1, item 6a
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Serious$1,050$630Aug 31, 1994Closed
Citation 1, item 6b
29 CFR 1910.178(o)(2) · Forklifts and other powered industrial trucks
Serious$0$0Aug 31, 1994Closed
Citation 1, item 6c Serious$0$0Aug 31, 1994Closed
Citation 1, item 7
29 CFR 1910.212(a)(1) · Machine guarding
Serious$700$380Aug 31, 1994Closed
Citation 1, item 8
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$875$515Aug 31, 1994Closed
Citation 1, item 9
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$525$295Aug 31, 1994Closed
Citation 1, item 10a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$700$400Aug 31, 1994Closed
Citation 1, item 10b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Aug 31, 1994Closed
Citation 1, item 11
29 CFR 1910.242(b) · Hand and power tools
Serious$700$400Aug 31, 1994Closed
Citation 1, item 12a
29 CFR 1910.303(c) · Electrical equipment, general requirements
Serious$700$400Aug 31, 1994Closed
Citation 1, item 12b
29 CFR 1910.334(c)(2) · Using electrical equipment
Serious$0$0Aug 31, 1994Closed
Citation 1, item 13
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$525$295Aug 31, 1994Closed
Citation 1, item 14a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$525$295Aug 31, 1994Closed
Citation 1, item 14b
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Aug 31, 1994Closed
Citation 1, item 14c
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$0$0Aug 31, 1994Closed
Citation 2, item 1
29 CFR 1910.110(f)(2)(ii) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Aug 31, 1994Closed
Citation 2, item 2
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 31, 1994Closed
Citation 2, item 3
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Aug 31, 1994Closed

Inspection 706291 OPENED SEP 10, 1985Closed

Planned · Records only · Safety · 33 employees at the site · Closed Sep 17, 1985

30 Industrial Drive, Ivyland, PA 18974 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Ivyland site logged 2 recordable injuries or illnesses among about 45 workers: 6.6 per 100 full-time workers, against a median of 1.9 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Fluitron Inc.
Ivyland · 2022
45 206.61.9

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(f)(4)

(4) Portable extinguishers. An adequate supply of suitable portable fire extinguishers shall be installed near all spraying areas.

29 CFR 1910.107(g)(3)

(3) Residue disposal. Residue scrapings and debris contaminated with residue shall be immediately removed from the premises and properly disposed of. Approved metal waste cans shall be provided wherever rags or waste are impregnated with finishing material and all such rags or waste deposited therein immediately after use. The contents of waste cans shall be properly disposed of at least once daily or at the end of each shift.

29 CFR 1910.107(g)(7)

(7) “No Smoking” signs. “No smoking” signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.332 · Training

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.36 · Exit route design

29 CFR 1910.94 · Ventilation

OSH Act Section 5 · General Duty Clause

Other metal tank (heavy gauge) manufacturing employers in Pennsylvania