OSHA has inspected Fox Tank Company 11 times in Texas since 2013.
The latest one began on Aug 11, 2022 on a referral, in Albany.
Those inspections ended with 59 citation items: 52 serious, 4 repeat and 3 other-than-serious.
Penalties were first proposed at $122,821 and now stand at $50,653, 59% lower after settlements or reviews.
Electrical wiring methods comes up most often in these citations: 12 items under 1910.305.
How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,425, and Fox Tank Company averages $8,008 (4 cited inspections).
Fox Tank Company also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Texas · latest 90 days of OSHA records
401employers cited
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2020, the Kerrville site logged 0 recordable injuries or illnesses among about 82 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Kerrville site
Kerrville · 2020
82
0
0
0.0
2.8
Albany site
Albany · 2020
31
0
0
0.0
2.8
Fox Tank Company
Kerrville · 2016
52
1
1
2.2
2.8
Included with any plan: 4 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(a) Table Z-1—(1) Substances with limits preceded by “C”—Ceiling Values. An employee's exposure to any substance in Table Z-1, the exposure limit of which is preceded by a “C”, shall at no time exceed the exposure limit given for that substance. If instantaneous monitoring is not feasible, then the ceiling shall be assessed as a 15-minute time weighted average exposure which shall not be exceeded at any time during the working day.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(c)(2)
(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.