Inspection 344247911 OPENED AUG 21, 2019Open
One Stickley Drive, Manlius, NY 13104 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Since 1975, OSHA inspectors have visited L. & J.G. Stickley, Inc. in New York 20 times.
The most recent inspection opened on Aug 21, 2019 on a referral, in Manlius and is still open.
In all, OSHA issued 139 citation items: 56 serious, 4 repeat and 79 other-than-serious.
The proposed penalties came to $94,216; today they stand at $60,592, 36% less.
The rule cited most here is 1910.107 (spray painting and finishing), 21 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. L. & J.G. Stickley, Inc. averages $25,369 across 1 cited inspection.
L. & J.G. Stickley, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
New York · latest 90 days of OSHA records
372employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch L. & J.G. Stickley, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show L. & J.G. Stickley, Inc. at 3 sites in 2 states. Together they've had 21 inspections and $61,592 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 3 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plansOne Stickley Drive, Manlius, NY 13104 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
One Stickley Drive, Manlius, NY 13104 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
One Stickley Drive, Manlius, NY 13104 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.36(h)(2) · Exit route design |
Serious | $4,617 | $2,770 | May 30, 2017 | Final |
| Citation 1, item 2a 29 CFR 1910.107(b)(10) · Spray painting and finishing |
Serious | $6,157 | $3,694 | May 30, 2017 | Final |
| Citation 1, item 2b 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Serious | $0 | $0 | May 30, 2017 | Final |
| Citation 1, item 3 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $12,675 | $7,605 | May 30, 2017 | Final |
| Citation 1, item 4a 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Serious | $6,157 | $3,694 | May 30, 2017 | Final |
| Citation 1, item 4b 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $0 | May 30, 2017 | Final |
| Citation 1, item 4c 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | May 30, 2017 | Final |
| Citation 1, item 5 29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection |
Serious | $12,675 | $7,605 | May 30, 2017 | Final |
| Citation 2, item 1 29 CFR 1910.36(d)(1) · Exit route design |
Other-than-serious | $0 | $0 | May 30, 2017 | Final |
| Citation 2, item 2 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | May 30, 2017 | Final |
One Stickley Drive, Manlius, NY 13104 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
One Stickley Drive, Manlius, NY 13104 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(1) · General requirements |
Serious | $1,875 | $1,219 | Nov 13, 2009 | Closed |
| Citation 1, item 2a 29 CFR 1910.106(e)(2)(ivd) · Flammable liquids |
Serious | $1,875 | $1,219 | Nov 13, 2009 | Closed |
| Citation 1, item 2b 29 CFR 1910.106(e)(9)(i) · Flammable liquids |
Serious | $0 | $0 | Nov 13, 2009 | Closed |
| Citation 1, item 3a 29 CFR 1910.107(b)(6) · Spray painting and finishing |
Other-than-serious | $1,125 | $731 | Nov 13, 2009 | Closed |
| Citation 1, item 3b 29 CFR 1910.107(b)(10) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Nov 13, 2009 | Closed |
| Citation 1, item 11a 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $0 | $1,219 | Nov 13, 2009 | Closed |
| Citation 1, item 11b 29 CFR 1910.213(p)(4) · Woodworking machinery |
Serious | $0 | $0 | Nov 13, 2009 | Closed |
| Citation 1, item 11c 29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Nov 13, 2009 | Closed |
| Citation 1, item 12a 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $0 | $1,219 | Nov 13, 2009 | Closed |
| Citation 1, item 12b 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $0 | $0 | Nov 13, 2009 | Closed |
| Citation 1, item 13a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $731 | Nov 13, 2009 | Closed |
| Citation 1, item 13b 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Nov 13, 2009 | Closed |
| Citation 1, item 13c 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Nov 13, 2009 | Closed |
| Citation 2, item 1 29 CFR 1910.305(g)(1)(iva) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Nov 13, 2009 | Closed |
One Stickley Drive, Manlius, NY 13104 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(1) · General requirements |
Serious | $1,125 | $731 | Apr 20, 2006 | Closed |
| Citation 1, item 2 29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes |
Other-than-serious | $1,125 | $731 | Apr 20, 2006 | Closed |
| Citation 1, item 3a 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Other-than-serious | $1,500 | $975 | Apr 20, 2006 | Closed |
| Citation 1, item 3b 29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 4 29 CFR 1910.106(d)(3)(ii) · Flammable liquids |
Other-than-serious | $1,125 | $731 | Apr 20, 2006 | Closed |
| Citation 1, item 5 29 CFR 1910.107(b)(1) · Spray painting and finishing |
Serious | $1,875 | $1,219 | Apr 20, 2006 | Closed |
| Citation 1, item 6 29 CFR 1910.107(c)(4) · Spray painting and finishing |
Serious | $1,875 | $1,219 | Apr 20, 2006 | Closed |
| Citation 1, item 7 29 CFR 1910.107(e)(9) · Spray painting and finishing |
Serious | $1,500 | $975 | Apr 20, 2006 | Closed |
| Citation 1, item 8a 29 CFR 1910.107(g)(1) · Spray painting and finishing |
Serious | $1,875 | $1,219 | Apr 20, 2006 | Closed |
| Citation 1, item 8b 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 9a 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $1,875 | $1,219 | Apr 20, 2006 | Closed |
| Citation 1, item 9b 29 CFR 1910.147(d)(4)(i) · Lockout/tagout |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 10 29 CFR 1910.157(g)(2) · Portable fire extinguishers |
Serious | $1,500 | $975 | Apr 20, 2006 | Closed |
| Citation 1, item 12 29 CFR 1910.212(b) · Machine guarding |
Other-than-serious | $1,125 | $731 | Apr 20, 2006 | Closed |
| Citation 1, item 13 29 CFR 1910.213(b)(3) · Woodworking machinery |
Serious | $1,125 | $731 | Apr 20, 2006 | Closed |
| Citation 1, item 18 29 CFR 1910.242(b) · Hand and power tools |
Other-than-serious | $1,125 | $731 | Apr 20, 2006 | Closed |
| Citation 1, item 20 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $1,875 | $1,219 | Apr 20, 2006 | Closed |
| Citation 1, item 22 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Other-than-serious | $1,125 | $731 | Apr 20, 2006 | Closed |
| Citation 1, item 23a 29 CFR 1910.332(b)(1) · Training |
Serious | $1,875 | $1,219 | Apr 20, 2006 | Closed |
| Citation 1, item 23b 29 CFR 1910.333(b)(2)(i) · Working near live electrical parts |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 24a 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $0 | $1,219 | Apr 20, 2006 | Closed |
| Citation 1, item 24b 29 CFR 1910.213(p)(4) · Woodworking machinery |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 24c 29 CFR 1910.213(r)(4) · Woodworking machinery |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 25a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $975 | Apr 20, 2006 | Closed |
| Citation 1, item 25b 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 25c 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 26a 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $0 | $975 | Apr 20, 2006 | Closed |
| Citation 1, item 26b 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 26c 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 2, item 1 29 CFR 1910.37(b)(4) · Exit routes |
Other-than-serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 2, item 2 29 CFR 1910.165(b)(5) · Employee alarm systems |
Other-than-serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 2, item 3 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Other-than-serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 2, item 4 29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts |
Other-than-serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 2, item 5 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 2, item 6 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 20, 2006 | Closed |
One Stickley Drive, Manlius, NY 13104 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(i)(2)(i) · Noise |
Other-than-serious | $2,000 | $0 | Jun 22, 2006 | Final |
| Citation 1, item 2 29 CFR 1910.106(d)(2)(iii) · Flammable liquids |
Other-than-serious | $2,000 | $0 | Jun 22, 2006 | Final |
| Citation 1, item 3 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Other-than-serious | $2,000 | $0 | Jun 22, 2006 | Final |
| Citation 1, item 4 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $2,000 | $500 | Jun 22, 2006 | Final |
| Citation 1, item 5 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Serious | $2,000 | $500 | Jun 22, 2006 | Final |
| Citation 2, item 1a 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Jun 22, 2006 | Final |
| Citation 2, item 1b 29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Jun 22, 2006 | Final |
1 Stickley Drive, Manlius, NY 13104 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1b 29 CFR 1910.213(n)(1) · Woodworking machinery |
Serious | $0 | $2,500 | May 10, 2002 | Closed |
1 Stickley Drive, Manlius, NY 13104 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(c)(2) · Spray painting and finishing |
Serious | $1,300 | $845 | May 27, 1999 | Closed |
| Citation 1, item 2 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $1,300 | $845 | May 27, 1999 | Closed |
| Citation 1, item 3 29 CFR 1910.213(c)(3) · Woodworking machinery |
Serious | $1,625 | $1,056 | May 27, 1999 | Closed |
| Citation 1, item 4 29 CFR 1910.213(g)(1) · Woodworking machinery |
Other-than-serious | $1,625 | $0 | May 27, 1999 | Closed |
| Citation 1, item 5 29 CFR 1910.213(p)(4) · Woodworking machinery |
Other-than-serious | $975 | $0 | May 27, 1999 | Closed |
| Citation 1, item 6 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Serious | $1,300 | $845 | May 27, 1999 | Closed |
| Citation 2, item 1 29 CFR 1910.37(q)(5) · Exit routes |
Other-than-serious | $0 | $0 | May 27, 1999 | Closed |
1 Stickley Drive, Manlius, NY 13104 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(a)(2) · Respiratory protection |
Other-than-serious | $550 | $440 | Aug 7, 1992 | Closed |
| Citation 1, item 1b 29 CFR 1910.134(e)(5)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 7, 1992 | Closed |
| Citation 1, item 1c 29 CFR 1910.1000(a)(3) · Air contaminants |
Other-than-serious | $0 | $0 | Aug 7, 1992 | Closed |
| Citation 1, item 1d 29 CFR 1910.1000(f)(2)(i) · Air contaminants |
Other-than-serious | $0 | $0 | Aug 7, 1992 | Closed |
1 Stickley Drive, Manlius, NY 13104 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(e)(2)(iva) · Flammable liquids |
Serious | $500 | $300 | Oct 2, 1990 | Closed |
| Citation 1, item 2 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Serious | $500 | $300 | Oct 2, 1990 | Closed |
| Citation 1, item 3 29 CFR 1910.1200(h) · Hazard communication |
Serious | $500 | $300 | Oct 2, 1990 | Closed |
| Citation 2, item 1 29 CFR 1910.133(a)(1) · Eye and face protection |
Repeat | $1,000 | $600 | Oct 2, 1990 | Closed |
1 Stickley Drive, Manlius, NY 13104 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.133(a)(1) · Eye and face protection |
Serious | $210 | $150 | Dec 16, 1987 | Closed |
| Citation 1, item 2 29 CFR 1910.213(p)(4) · Woodworking machinery |
Serious | $210 | $150 | Dec 16, 1987 | Closed |
| Citation 2, item 1 29 CFR 1910.37(q)(2) · Exit routes |
Other-than-serious | $0 | $0 | Dec 16, 1987 | Closed |
| Citation 2, item 2 29 CFR 1910.106(e)(6)(i) · Flammable liquids |
Other-than-serious | $0 | $0 | Dec 16, 1987 | Closed |
| Citation 2, item 3 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Dec 16, 1987 | Closed |
| Citation 2, item 4 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Dec 16, 1987 | Closed |
| Citation 2, item 5 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Dec 16, 1987 | Closed |
| Citation 2, item 6 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Dec 16, 1987 | Closed |
| Citation 2, item 7 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Dec 16, 1987 | Closed |
300 Orchard St, Fayetteville, NY 13066 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $180 | $90 | Nov 2, 1984 | Closed |
| Citation 2, item 1 29 CFR 1910.107(g)(1) · Spray painting and finishing |
Repeat | $160 | $80 | Nov 2, 1984 | Closed |
| Citation 2, item 2 29 CFR 1910.213(g)(1) · Woodworking machinery |
Repeat | $720 | $360 | Nov 2, 1984 | Closed |
| Citation 2, item 3 29 CFR 1910.242(b) · Hand and power tools |
Repeat | $160 | $80 | Nov 2, 1984 | Closed |
| Citation 3, item 1 29 CFR 1910.22(a)(1) · General requirements |
Other-than-serious | $0 | $0 | Nov 2, 1984 | Closed |
| Citation 3, item 2 29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Nov 2, 1984 | Closed |
| Citation 3, item 3 29 CFR 1910.101(b) · Compressed gases (general requirements) |
Other-than-serious | $0 | $0 | Nov 2, 1984 | Closed |
| Citation 3, item 4 29 CFR 1910.107(e)(2) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Nov 2, 1984 | Closed |
| Citation 3, item 5 29 CFR 1910.184(e)(3)(i) · Slings |
Other-than-serious | $0 | $0 | Nov 2, 1984 | Closed |
| Citation 3, item 6 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Nov 2, 1984 | Closed |
| Citation 3, item 7 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Nov 2, 1984 | Closed |
300 Orchard St, Fayetteville, NY 13066 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.213(g)(1) · Woodworking machinery |
Serious | $200 | $75 | May 19, 1982 | Closed |
| Citation 1, item 2 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $150 | $75 | May 19, 1982 | Closed |
| Citation 2, item 1 29 CFR 1910.106(e)(9)(iii) · Flammable liquids |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 2 29 CFR 1910.107(b)(1) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 3 29 CFR 1910.107(b)(2) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 4 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Other-than-serious | $0 | $0 | May 5, 1982 | Closed |
| Citation 2, item 5 29 CFR 1910.107(b)(9) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 6 29 CFR 1910.107(f)(3) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 7 29 CFR 1910.107(g)(1) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 8 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 9 29 CFR 1910.107(g)(7) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 10 29 CFR 1910.134(f)(2)(iii) · Respiratory protection |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 11 29 CFR 1910.134(f)(3) · Respiratory protection |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 12 29 CFR 1910.134(f)(5)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 13 29 CFR 1910.213(b)(3) · Woodworking machinery |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 14 29 CFR 1910.215(a)(2) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 15 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 16 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 17 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 18 29 CFR 1910.242(b) · Hand and power tools |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
| Citation 2, item 19 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 29, 1982 | Closed |
300 Orchard Street, Fayetteville, NY 13066 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
300 Orchard Street, Fayetteville, NY 13066 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
300 Orchard Street, Fayetteville, NY 13066 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(b) · Noise |
Other-than-serious | $0 | $0 | Jul 24, 1975 | Closed |
300 Orchard Street, Fayetteville, NY 13066 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
300 Orchard Street, Fayetteville, NY 13066 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
300 Orchard Street, Fayetteville, NY 13066 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | May 12, 1975 | Closed |
| Citation 1, item 2 29 CFR 1910.157(a)(3) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | May 12, 1975 | Closed |
| Citation 1, item 3 29 CFR 1910.157(a)(6) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | May 12, 1975 | Closed |
| Citation 1, item 4 | Other-than-serious | $0 | $0 | May 12, 1975 | Closed |
| Citation 1, item 5 29 CFR 1910.242(b) · Hand and power tools |
Other-than-serious | $30 | $30 | May 12, 1975 | Closed |
| Citation 1, item 6 | Other-than-serious | $0 | $0 | May 12, 1975 | Closed |
| Citation 1, item 7 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Other-than-serious | $25 | $25 | May 12, 1975 | Closed |
| Citation 1, item 8 29 CFR 1910.212(a)(5) · Machine guarding |
Other-than-serious | $25 | $25 | May 12, 1975 | Closed |
| Citation 1, item 9 | Other-than-serious | $0 | $0 | May 12, 1975 | Closed |
| Citation 1, item 10 29 CFR 1910.213(d)(1) · Woodworking machinery |
Other-than-serious | $25 | $25 | May 12, 1975 | Closed |
| Citation 1, item 11 29 CFR 1910.213(g)(1) · Woodworking machinery |
Other-than-serious | $25 | $25 | May 12, 1975 | Closed |
| Citation 1, item 12 29 CFR 1910.213(c)(3) · Woodworking machinery |
Other-than-serious | $0 | $0 | May 12, 1975 | Closed |
| Citation 1, item 13 29 CFR 1910.213(c)(2) · Woodworking machinery |
Other-than-serious | $0 | $0 | May 12, 1975 | Closed |
| Citation 1, item 14 29 CFR 1910.213(a)(13) · Woodworking machinery |
Other-than-serious | $60 | $60 | May 12, 1975 | Closed |
| Citation 1, item 15 29 CFR 1910.213(c)(1) · Woodworking machinery |
Other-than-serious | $80 | $80 | May 12, 1975 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Manlius site logged 4 recordable injuries or illnesses among about 319 workers: 1.4 per 100 full-time workers, against a median of 3.7 for its industry. Those cases cost 70 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| L. & J. G. Stickley Manlius · 2025 | 319 | 4 | 2 | 1.4 | 3.7 |
| L. & J. G. Stickley, Inc. Manlius · 2018 | 550 | 20 | 9 | 3.5 | 3.7 |
| Stickley, Audi & Co.- Fayetteville Fayetteville · 2017 | 21 | 0 | 0 | 0.0 | 0.0 |
Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansEmployers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Feb 2, 2016, Manlius: Amputation · amputations · fingertip(s)
Two employees were removing sheets of plywood from old shelving when a piece about 3' by 6' slipped. The injured employee's right pinky fingertip was caught against the plywood and the skin tore off (no bone damage) within the employee's glove. The employee was hospitalized.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.101(b)
(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.
29 CFR 1910.106(d)(2)(iii)
(iii) Size. Flammable liquid containers shall be in accordance with Table H-12, except that glass or plastic containers of no more than 1-gallon capacity may be used for a Category 1 or 2 flammable liquid if:
29 CFR 1910.106(d)(3)(ii)
(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.