OSHA SearchOSHA records by employer

Marine Corps Logistics Base Barstow: OSHA inspections and violations

Barstow, California · National Security · NAICS 928110

10inspections
52citation items
$0current penalties
Feb 2, 2016last inspection

Since 1995, OSHA inspectors have visited Marine Corps Logistics Base Barstow in California 10 times.

The most recent inspection opened on Feb 2, 2016 after a complaint, in Barstow.

In all, OSHA issued 52 citation items: 36 serious and 16 other-than-serious.

No penalty came with these citations.

The rule cited most here is 1910.335 (safeguards for personnel protection), 4 times.

Among public administration employers, the typical cited inspection since 2015 ends with a $0 penalty. Marine Corps Logistics Base Barstow averages $0 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

It reported 1 severe injury to OSHA since 2015.

Marine Corps Logistics Base Barstow: OSHA citation items per year, 1995 to 2016
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,134employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch Marine Corps Logistics Base Barstow and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341230761 OPENED FEB 2, 2016Closed

Complaint · Partial · Safety · Federal government · 64 employees at the site · Closed Jul 29, 2016

Bldg. 197 Mclb Barstow, Barstow, CA 92311 · National Security · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(b)(2)(ii)(a) · Working near live electrical parts
Serious$0$0Jun 16, 2016Final
Citation 1, item 2
29 CFR 1910.335(a)(1)(ii) · Safeguards for personnel protection
Serious$0$0Jun 16, 2016Final

Inspection 340990548 OPENED OCT 14, 2015Closed

Complaint · Partial · Safety · Federal government · 64 employees at the site · Closed May 17, 2016

Bldg. 197 Mclb Barstow, Barstow, CA 92311 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.67(c)(2)(ii) · Vehicle-mounted elevating and rotating work platforms
Serious$0$0Apr 1, 2016Final
Citation 1, item 2 Serious$0$0Apr 1, 2016Final
Citation 1, item 3a
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$0$0Apr 1, 2016Final
Citation 1, item 3b
29 CFR 1910.335(a)(2)(i) · Safeguards for personnel protection
Serious$0$0Apr 1, 2016Final

Inspection 312422447 OPENED SEP 25, 2008Closed

Planned · Complete · Safety · Federal government · 1,200 employees at the site · Closed May 4, 2009

Yermo Annex Maintenance Facility, Barstow, CA 92311 · National Security · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$0$0Apr 16, 2009Closed
Citation 1, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Apr 16, 2009Closed
Citation 1, item 3
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Apr 16, 2009Closed
Citation 1, item 4
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Serious$0$0Apr 16, 2009Closed
Citation 1, item 5
29 CFR 1910.132(d)(1)(i) · Personal protective equipment, general requirements
Serious$0$0Apr 16, 2009Closed
Citation 1, item 6
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Serious$0$0Apr 16, 2009Closed
Citation 1, item 7
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$0$0Apr 16, 2009Closed

Inspection 310771134 OPENED FEB 12, 2007Closed

Complaint · Partial · Health · Federal government · 1,000 employees at the site · Closed Aug 2, 2007

Yermo Annex - Building 573 Repair Division, Barstow, CA 92311 · National Security · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Jun 27, 2007Closed
Citation 1, item 2 Serious$0$0Jun 27, 2007Closed

Inspection 109332387 OPENED OCT 6, 2003Closed

Accident · Partial · Safety · Federal government · 377 employees at the site · Closed Feb 4, 2004

Yermo Annex - Building 573 Repair Division, Barstow, CA 92311 · National Security · OSHA's record · Phone and website on Google Maps

Incident on Oct 3, 2003 (fatal): Employee is electrocuted by arc from amplifier

At approximately 7:21 a.m. on October 3, 2003, an employee was working an integr ated systems mechanic at the Marine Corps base. The Marine Corps base was tasked to restore, overhaul and repair the radar sets. The radar set involved in the a ccident was the AN/TPS-63B Radar Set manufactured by Westinghouse. Reportedly, t he unit could be moved anywhere in the world and set up to monitor aircraft with in about 100-mile radius of its location. These radar sets were moth balled in t he mid 1990s, but they were used again because of increased military activity by the Marine Corps. The complete radar set looked like a small intermodal shippin g container with an articulating antenna on the top and various electrical cabin ets inside. The container was about 9-ft high, by 9-ft wide by 9-ft long. At the time of the accident, two coworkers had just powered up the radar set to verify the transformer installations they completed the previous night. They were insi de the radar set near electrical equipment located in a cabinet. One coworker po inted out to the employee that one of the gauges did not work on the equipment. The employee then pointed inside the cabinet at the high voltage deck. Electrici ty then arced from the deck to the employee's finger. The employee indicated tha t he was not okay and then collapsed. Artificial respiration was attempted witho ut reviving the employee. It appeared that emergency services arrived at the sce ne within about six- minutes of the accident. The equipment, known as the TWT Am plifier, was located in a metal cabinet on an interior side wall near the rear o f the radar unit. The equipment's panel cover was open, the plastic shields were removed, and the electric power was on at the time of the accident. There was a nother metal, electrical cabinet located 27-in. away on the opposite interior wa ll of the radar unit. No insulating gloves or curtains were used.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$0$0Nov 26, 2003Closed
Citation 1, item 2
29 CFR 1910.335(a)(2)(ii) · Safeguards for personnel protection
Serious$0$0Nov 26, 2003Closed

Inspection 109352062 OPENED JUL 30, 2002Closed

Planned · Complete · Safety · Federal government · 1,300 employees at the site · Closed Feb 28, 2003

Yermo Annex, Barstow, CA 92311 · Military Armored Vehicle, Tank, and Tank Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(e)(5)(iv) · Guarding floor and wall openings and holes
Serious$0$0Dec 10, 2002Closed
Citation 1, item 2
29 CFR 1910.37(f)(6) · Exit routes
Serious$0$0Dec 10, 2002Closed
Citation 1, item 3
29 CFR 1910.141(g)(2) · Sanitation
Serious$0$0Dec 10, 2002Closed
Citation 1, item 4
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Dec 10, 2002Closed
Citation 1, item 5
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$0$0Dec 10, 2002Closed
Citation 1, item 6
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$0$0Dec 10, 2002Closed
Citation 1, item 7 Serious$0$0Dec 10, 2002Closed
Citation 1, item 8
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$0$0Dec 10, 2002Closed
Citation 1, item 9
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Dec 10, 2002Closed
Citation 1, item 10
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 10, 2002Closed
Citation 1, item 11
29 CFR 1910.242(b) · Hand and power tools
Serious$0$0Dec 10, 2002Closed
Citation 1, item 12
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Dec 10, 2002Closed
Citation 1, item 13
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$0$0Dec 10, 2002Closed
Citation 2, item 1 Other-than-serious$0$0Dec 10, 2002Closed
Citation 2, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Dec 10, 2002Closed
Citation 2, item 3
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Dec 10, 2002Closed
Citation 2, item 4
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 10, 2002Closed
Citation 2, item 5
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Dec 10, 2002Closed
Citation 2, item 6
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 10, 2002Closed
Citation 2, item 7 Other-than-serious$0$0Dec 10, 2002Closed
Citation 2, item 8 Other-than-serious$0$0Dec 10, 2002Closed
Citation 2, item 9 Other-than-serious$0$0Dec 10, 2002Closed
Citation 2, item 10 Other-than-serious$0$0Dec 10, 2002Closed

Inspection 305564510 OPENED JUL 30, 2002Closed

Planned · Complete · Safety · Federal government · 1,300 employees at the site · Closed Jan 28, 2003

Fleet Support Division, Yermo Annex, CA 92398 · Military Armored Vehicle, Tank, and Tank Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(q)(6) · Exit routes
Other-than-serious$0$0Dec 10, 2002Closed
Citation 1, item 2
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 10, 2002Closed
Citation 1, item 3
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 10, 2002Closed

Inspection 117950840 OPENED MAY 19, 1998Closed

Complaint · Partial · Safety · Federal government · 1,200 employees at the site · Closed Sep 14, 1998

Yermo Annex - Building 573 Repair Division, Barstow, CA 92311 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Serious$0$0Aug 7, 1998Closed
Citation 1, item 2
29 CFR 1910.305(j)(2)(ii) · Electrical wiring methods
Serious$0$0Aug 7, 1998Closed
Citation 2, item 1
29 CFR 1910.119(e)(1) · Process safety management
Other-than-serious$0$0Aug 7, 1998Closed
Citation 2, item 2
29 CFR 1910.1450(e)(1) · Occupational exposure to hazardous chemicals in laboratories
Other-than-serious$0$0Aug 7, 1998Closed
2 older inspections

Inspection 110621240 OPENED MAR 24, 1997Closed

Planned · Complete · Safety · Federal government · 1,200 employees at the site · Closed May 17, 1999

Yermo Annex - Building 573 Repair Division, Barstow, CA 92311 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(d)(1) · Respiratory protection
Serious$0$0Apr 23, 1997Closed
Citation 1, item 2
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$0$0Apr 23, 1997Closed
Citation 1, item 3
29 CFR 1910.242(b) · Hand and power tools
Serious$0$0Apr 23, 1997Closed
Citation 2, item 1 Other-than-serious$0$0Apr 23, 1997Closed

Inspection 106058324 OPENED MAY 30, 1995Closed

Complaint · Partial · Health · Federal government · 400 employees at the site · Closed Jul 13, 1995

Yermo Annex - Building 573 Repair Division, Barstow, CA 92311 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1025(h)(1) · Lead in general industry
Serious$0$0Jun 2, 1995Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 13, 2018, Barstow: Hospitalization · coughing and throat irritation- toxic, noxious, or allergenic effect · body systems

An employee was removing expired chlorine tabs from a dilution system tank that was shut down for maintenance. He was exposed to chlorinated water from a leak in the system, as well as wet chlorine tablets stored in a bucket during the maintenance. He reported having a heavy cough after his shift and difficulty breathing the next day and was hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(h)(1)

(h) Housekeeping—(1) Surfaces. All surfaces shall be maintained as free as practicable of accumulations of lead.

29 CFR 1910.1027 · Cadmium

29 CFR 1910.1027(d)(5)(i)

(5) Employee Notification of Monitoring Results. (i) The employer must, within 15 working days after the receipt of the results of any monitoring performed under this section, notify each affected employee of these results either individually in writing or by posting the results in an appropriate location that is accessible to employees.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(9)(iii)

(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.

29 CFR 1910.119 · Process safety management

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.1450 · Occupational exposure to hazardous chemicals in laboratories

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.332 · Training

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.37 · Exit routes

29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms

29 CFR 1960.11

29 CFR 1960.28

29 CFR 1960.59

29 CFR 1960.67

29 CFR 1960.69

Other national security employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.