OSHA SearchOSHA records by employer

Universal Builders Supply Inc: OSHA inspections and violations

New York, New York · All Other Specialty Trade Contractors · NAICS 238990

21inspections
64citation items
$57,493current penalties
Nov 19, 2015last inspection

OSHA has inspected Universal Builders Supply Inc 21 times in New York since 1984.

The latest one began on Nov 19, 2015 as part of a related case, in New York.

Those inspections ended with 64 citation items: 48 serious and 16 other-than-serious.

Penalties were first proposed at $76,535 and now stand at $57,493, 25% lower after settlements or reviews.

Scope, application, and definitions applicable to this subpart comes up most often in these citations: 6 items under 1926.500.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Universal Builders Supply Inc averages $5,600 (1 cited inspection).

2 inspections on this page followed a fatal incident.

Universal Builders Supply Inc: OSHA citation items per year, 1984 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Universal Builders Supply Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341250579 OPENED NOV 19, 2015Closed

Unprogrammed related · Partial · Safety · 11 employees at the site · Closed Aug 31, 2016

50 West St., New York, NY 10006 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1052(c)(4)(iv) · Stairways in construction
Serious$2,800$2,800Mar 28, 2016Final
Citation 1, item 2
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$2,800$2,800Mar 28, 2016Final

Inspection 307535971 OPENED OCT 7, 2004Closed

Complaint · Partial · Safety · 14 employees at the site · Closed Nov 24, 2004

7401 South Broadway, Red Hook, NY 12571 · Construction and Mining (except Oil Well) Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$975$975Oct 20, 2004Closed
Citation 1, item 2
29 CFR 1910.176(b) · Material storage and aisles
Serious$1,625$1,625Oct 20, 2004Closed
Citation 1, item 3
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$1,625$1,625Oct 20, 2004Closed
Citation 2, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 20, 2004Closed

Inspection 306334053 OPENED MAR 28, 2003Closed

Accident · Complete · Safety · 15 employees at the site · Closed May 15, 2003

100 Morton Street, New York, NY 10014 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Incident on Mar 28, 2003 (fatal): Employee falls from hoist tower

At approximately 10:45 a.m. on March 28, 2003, Employee #1 and two coworkers wer e unloading doors from the Alimack hoist tower to the third floor of a construct ion site. There was an approximately 3-foot gap between the Alimack cab and the edge of the building. The workers laid down two 4-inch by 4-inch timbers approxi mately 30 inches apart, and put 0.75 inch, 8-feet by 4-feet plywood on top to ma ke a bridge for the delivery. When the delivery was finished, the two coworkers went into the Alimack cab and slid the plywood into the cab. Employee #1 then pr oceeded to walk on the two 4-inch by 4-inch timbers to the Alimack cab when one timber broke. He fell approximately 36 feet to the concrete street below. He was transported to Saint Vincent Hospital, where he was pronounced dead at 11:20 a. m. in the emergency room.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$5,000$4,500Apr 22, 2003Closed
Citation 1, item 4a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$5,000$4,500Apr 22, 2003Closed
Citation 1, item 4b
29 CFR 1926.501(a)(2) · Fall protection in construction
Serious$0$0Apr 22, 2003Closed

Inspection 302945704 OPENED FEB 27, 2001Closed

Unprogrammed other · Partial · Safety · 7 employees at the site · Closed Sep 27, 2001

270 West 43rd Street, New York, NY 10036 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$2,000$1,500May 8, 2001Closed
Citation 1, item 1b
29 CFR 1926.404(b)(1)(iiie) · Ground-fault protection on job sites
Serious$0$0May 8, 2001Closed
Citation 1, item 2
29 CFR 1926.451(g)(2) · Scaffolds, general requirements
Other-than-serious$4,000$1,000May 8, 2001Closed
Citation 1, item 3
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$1,600$1,200May 8, 2001Closed

Inspection 302940481 OPENED MAR 10, 2000Closed

Unprogrammed related · Complete · Safety · 65 employees at the site · Closed Jul 28, 2000

353 West 57 Street, New York, NY 10019 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,625$0Jun 7, 2000Closed
Citation 1, item 2
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,300$910Jun 7, 2000Closed
Citation 1, item 3
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$1,625$1,138Jun 7, 2000Closed

Inspection 300619624 OPENED JUL 21, 1998Closed

Referral · Partial · Safety · 100 employees at the site · Closed Aug 4, 1999

4 Times Square, New York, NY 10036 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$7,000$4,900Jan 20, 1999Final
Citation 1, item 2
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$7,000$4,900Jan 20, 1999Final
Citation 1, item 3
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$5,000$3,500Jan 20, 1999Final
Citation 1, item 4
29 CFR 1926.452(c)(6) · Rules for each type of scaffold
Serious$7,000$4,900Jan 20, 1999Final

Inspection 300618048 OPENED JUN 26, 1998Closed

Accident · Complete · Safety · 100 employees at the site · Closed Nov 3, 1999

4 Times Square, New York, NY 10036 · OSHA's record · Phone and website on Google Maps

Incident on Jun 26, 1998 (fatal): Employee crushed by material hoist

Employee #1 was working in an active hoist shaft when the hoist crushed him to d eath.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$3,000$2,100Dec 23, 1998Final
Citation 1, item 2
29 CFR 1926.501(b)(3) · Fall protection in construction
Serious$3,000$2,100Dec 23, 1998Final
Citation 1, item 3
29 CFR 1926.503(a)(2) · Fall protection training in construction
Serious$3,000$2,100Dec 23, 1998Final

Inspection 300616117 OPENED JAN 15, 1998Closed

Unprogrammed related · Partial · Safety · 20 employees at the site · Closed May 29, 1998

520 W 43 St., New York, NY 10036 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

13 older inspections

Inspection 106726672 OPENED FEB 25, 1992Closed

Planned · Complete · Safety · 16 employees at the site · Closed Jun 30, 1992

64 South Broadway, Red Hook, NY 12571 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Serious$500$500Apr 6, 1992Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Apr 6, 1992Closed
Citation 2, item 2 Other-than-serious$0$0Apr 6, 1992Closed
Citation 2, item 3
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Apr 6, 1992Closed
Citation 2, item 4
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Apr 6, 1992Closed

Inspection 106890700 OPENED NOV 22, 1991Closed

Planned · Complete · Safety · 4 employees at the site · Closed Dec 12, 1991

216 South Terrace Avenue, Mount Vernon, NY 10550 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$225$225Dec 2, 1991Closed
Citation 1, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$225$225Dec 2, 1991Closed

Inspection 100600667 OPENED MAR 14, 1990Closed

Complaint · Complete · Safety · 300 employees at the site · Closed Mar 28, 1990

151 West 45th Street, New York, NY 10036 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 100510775 OPENED APR 6, 1989Closed

Planned · Complete · Safety · 7 employees at the site · Closed Feb 1, 1990

388 Greenwich Street, New York, NY 10013 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Serious$180$180Aug 3, 1989Closed
Citation 1, item 2
29 CFR 1926.59(g)(1) · Hazard communication
Serious$180$180Aug 3, 1989Closed
Citation 1, item 3
29 CFR 1926.59(h) · Hazard communication
Serious$180$180Aug 3, 1989Closed
Citation 1, item 4
29 CFR 1926.552(a)(2) · Material hoists, personnel hoists, and elevators
Serious$810$810Aug 3, 1989Closed
Citation 1, item 5
29 CFR 1926.552(b)(2) · Material hoists, personnel hoists, and elevators
Serious$810$810Aug 3, 1989Closed
Citation 1, item 6
29 CFR 1926.552(c)(4) · Material hoists, personnel hoists, and elevators
Serious$640$640Aug 3, 1989Closed

Inspection 106526049 OPENED NOV 29, 1988Closed

Planned · Complete · Safety · 65 employees at the site · Closed Mar 14, 1989

64 South Broadway, Red Hook, NY 12571 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.252(a)(2)(iib) · Welding fire safety
Serious$480$480Jan 12, 1989Closed
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$480$480Jan 12, 1989Closed
Citation 2, item 1
29 CFR 1904.6 · Determination of new cases
Other-than-serious$0$0Jan 12, 1989Closed
Citation 2, item 2 Other-than-serious$0$0Jan 12, 1989Closed
Citation 2, item 3
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Jan 12, 1989Closed
Citation 2, item 4
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Jan 12, 1989Closed

Inspection 100487065 OPENED MAR 29, 1988Closed

Unprogrammed related · Complete · Safety · 7 employees at the site · Closed Oct 3, 1988

25-01 Jackson Avenue, Long Island City, NY 11101 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$420$320Jul 19, 1988Closed
Citation 1, item 2
29 CFR 1926.350(a)(1) · Gas welding and cutting
Serious$240$240Jul 19, 1988Closed
Citation 1, item 3
29 CFR 1926.350(a)(9) · Gas welding and cutting
Serious$240$240Jul 19, 1988Closed
Citation 1, item 4
29 CFR 1926.350(j) · Gas welding and cutting
Serious$240$240Jul 19, 1988Closed
Citation 1, item 5
29 CFR 1926.500(b)(1) · Scope, application, and definitions applicable to this subpart
Serious$420$320Jul 19, 1988Closed
Citation 1, item 6
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$360$360Jul 19, 1988Closed
Citation 1, item 7
29 CFR 1926.500(d)(2) · Scope, application, and definitions applicable to this subpart
Serious$420$300Jul 19, 1988Closed
Citation 1, item 8
29 CFR 1926.500(e)(1)(iii) · Scope, application, and definitions applicable to this subpart
Serious$180$180Jul 19, 1988Closed

Inspection 17772005 OPENED FEB 25, 1987Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed Jun 1, 1987

Ellis Island, New York, NY 10004 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$240$240May 5, 1987Closed
Citation 1, item 1b
29 CFR 1926.500(d)(2) · Scope, application, and definitions applicable to this subpart
Serious$0$0May 5, 1987Closed
Citation 1, item 2
29 CFR 1926.500(b)(1) · Scope, application, and definitions applicable to this subpart
Serious$300$300May 5, 1987Closed

Inspection 100619048 OPENED JAN 27, 1987Closed

Planned · Complete · Safety · 5 employees at the site · Closed Feb 5, 1987

139 Pierrepont St., Brooklyn, NY 11201 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 17810573 OPENED NOV 21, 1986Closed

Planned · Complete · Safety · 30 employees at the site · Closed Dec 29, 1986

64 South Broadway, Red Hook, NY 12571 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Dec 3, 1986Closed
Citation 1, item 2
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0Dec 3, 1986Closed
Citation 1, item 3
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Dec 3, 1986Closed
Citation 1, item 4
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Other-than-serious$0$0Dec 3, 1986Closed
Citation 1, item 5
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Dec 3, 1986Closed

Inspection 2276376 OPENED JUL 11, 1985Closed

Unprogrammed other · Complete · Safety · 40 employees at the site · Closed May 7, 1986

Battery Park City - Bldg. "d", New York, NY 10007 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$240$200Oct 30, 1985Closed
Citation 1, item 2
29 CFR 1926.28(a) · Personal protective equipment
Serious$400$120Oct 30, 1985Closed
Citation 1, item 3
29 CFR 1926.400(h)(1) · Introduction
Serious$400$200Oct 30, 1985Closed
Citation 1, item 4
29 CFR 1926.401(c) · [Reserved]
Serious$400$200Oct 30, 1985Closed

Inspection 1035039 OPENED OCT 24, 1984Closed

Planned · No inspection · Safety · Closed Oct 24, 1984

216 South Terrace Ave, Mount Vernon, NY 10550 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 1088327 OPENED JUL 19, 1984Closed

Unprogrammed other · Complete · Safety · 15 employees at the site · Closed Dec 10, 1984

200 Vesey Street Battery Park City Bldg C, Ny, NY 10007 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 1088384 OPENED JUL 17, 1984Closed

Planned · Complete · Safety · 4 employees at the site · Closed Aug 21, 1984

Statue Of Liberty, Liberty Island, NY 10004 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(13) · Scaffolds, general requirements
Serious$350$250Aug 1, 1984Closed
Citation 2, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$0$0Aug 1, 1984Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1904.6 · Determination of new cases

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.141 · Sanitation

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.400 · Introduction

29 CFR 1926.401 · [Reserved]

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.552 · Material hoists, personnel hoists, and elevators

29 CFR 1926.59 · Hazard communication

OSH Act Section 5 · General Duty Clause

Other all other specialty trade contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.