OSHA SearchOSHA records by employer

Vision Systems, Inc: OSHA inspections and violations

Tarpon Springs, Florida · Optical Instrument and Lens Manufacturing · NAICS 333314

1inspections
14citation items
$11,407current penalties
Aug 18, 2016last inspection

OSHA inspectors have visited Vision Systems, Inc in Florida one time.

It opened on Aug 18, 2016 after a complaint, in Tarpon Springs.

In all, OSHA issued 14 citation items: 7 serious and 7 other-than-serious.

The proposed penalties came to $19,012; today they stand at $11,407, 40% less.

The rule cited most here is 1910.107 (spray painting and finishing), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Vision Systems, Inc averages $11,407 across 1 cited inspection.

Vision Systems, Inc: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Vision Systems, Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341723633 OPENED AUG 18, 2016Closed

Complaint · Partial · Health · 34 employees at the site · Closed Mar 8, 2017

769 Wesley Ave, Tarpon Springs, FL 34689 · Optical Instrument and Lens Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$3,802$2,281Feb 10, 2017Final
Citation 1, item 2a
29 CFR 1910.107(b)(1) · Spray painting and finishing
Serious$5,070$3,042Feb 10, 2017Final
Citation 1, item 2b
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$0$0Feb 10, 2017Final
Citation 1, item 2c
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Feb 10, 2017Final
Citation 1, item 2d
29 CFR 1910.107(h)(12) · Spray painting and finishing
Serious$0$0Feb 10, 2017Final
Citation 1, item 3
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$5,070$3,042Feb 10, 2017Final
Citation 1, item 4
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$5,070$3,042Feb 10, 2017Final
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Feb 10, 2017Final
Citation 2, item 2
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Feb 10, 2017Final
Citation 2, item 3
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Feb 10, 2017Final
Citation 2, item 4
29 CFR 1910.305(a)(2)(x) · Electrical wiring methods
Other-than-serious$0$0Feb 10, 2017Final
Citation 2, item 5
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Feb 10, 2017Final
Citation 2, item 6
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Feb 10, 2017Final
Citation 2, item 7
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Feb 10, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(1)

(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.305 · Electrical wiring methods

OSH Act Section 5 · General Duty Clause

Other optical instrument and lens manufacturing employers in Florida

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.