Inspection 349054262 OPENED JUL 14, 2026Closed
1670 Drydock Avenue Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
North Charleston, South Carolina · Ship Building and Repairing · NAICS 336611
Since 1972, OSHA inspectors have visited Detyens Shipyards, Inc. in South Carolina 67 times.
The most recent inspection opened on Jul 14, 2026 on a referral, in North Charleston.
In all, OSHA issued 343 citation items: 155 serious, 8 repeat and 180 other-than-serious.
The proposed penalties came to $598,673; today they stand at $397,042, 34% less.
The rule cited most here is 1910.134 (respiratory protection), 45 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Detyens Shipyards, Inc. averages $25,205 across 9 cited inspections.
6 inspections on this page followed a fatal incident.
Detyens Shipyards, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 4 severe injuries to OSHA since 2015.
South Carolina · latest 90 days of OSHA records
42employers cited
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Carolina
Checking a subcontractor, a client or your own company? Watch Detyens Shipyards, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company1670 Drydock Avenue Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Avenue Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1915.81(a)(3) · Housekeeping |
Other-than-serious | $0 | $0 | Feb 10, 2026 | Final |
1670 Dry Dock Avenue, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Usns 1st Lt Jack Lummus Drydock #5 Detyens Shipyard, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
Incident on Nov 11, 2023 (fatal): Employee is killed in fall off ladder
At 11:00 a.m. on November 11, 2023, Employee #1 was descending a ladder into an empty marine vessel gas fuel tank to perform work at the very bottom of the tank (a distance of 30-feet). While standing on a ladder platform 19.5 feet from the bottom of the tank, Employee #1 was preparing to pass a jumper hose to another employee located underneath that platform, and he fell. Employee #1 was killed due to head trauma.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1915.82(c)(1) · Lighting |
Serious | $16,131 | $8,065 | Apr 18, 2024 | Final |
| Citation 1, item 2 29 CFR 1915.155(a)(1) · Head protection |
Other-than-serious | $12,676 | $0 | Apr 18, 2024 | Final |
| Citation 2, item 1 29 CFR 1915.77(c) · Working surfaces |
Repeat | $161,323 | $112,986 | Apr 18, 2024 | Final |
1670 Drydock Avenue Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Avenue Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(e)(2)(iv)(b) · Flammable liquids |
Serious | $4,838 | $2,903 | Aug 24, 2023 | Final |
1670 Drydock Avenue Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Avenue Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.25(b)(1) · Stairways |
Serious | $8,349 | $5,009 | Aug 25, 2023 | Final |
| Citation 1, item 2 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $8,349 | $5,009 | Aug 25, 2023 | Final |
| Citation 1, item 3 29 CFR 1910.213(h)(1) · Woodworking machinery |
Serious | $10,436 | $6,262 | Aug 25, 2023 | Final |
| Citation 1, item 4 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $8,349 | $5,009 | Aug 25, 2023 | Final |
| Citation 1, item 5 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $6,261 | $3,757 | Aug 25, 2023 | Final |
| Citation 1, item 6 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Serious | $6,261 | $3,757 | Aug 25, 2023 | Final |
| Citation 1, item 7 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Serious | $10,436 | $6,262 | Aug 25, 2023 | Final |
| Citation 1, item 8 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $6,261 | $3,757 | Aug 25, 2023 | Final |
| Citation 1, item 9 29 CFR 1910.305(g)(1)(iv)(b) · Electrical wiring methods |
Serious | $8,349 | $5,009 | Aug 25, 2023 | Final |
| Citation 1, item 10 29 CFR 1915.73(f) · Guarding of deck openings and edges |
Serious | $8,349 | $5,009 | Aug 25, 2023 | Final |
| Citation 1, item 11 29 CFR 1915.75(d) · Access to and guarding of dry docks and marine railways |
Serious | $10,436 | $6,262 | Aug 25, 2023 | Final |
| Citation 2, item 1 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Aug 25, 2023 | Final |
| Citation 2, item 2 29 CFR 1915.89(n)(3)(iv) · Control of hazardous energy (lockout/tags-plus) |
Other-than-serious | $0 | $0 | Aug 25, 2023 | Final |
1670 Drydock Avenue Bldg 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Usns 1st Lt. Jack Lummus 1670 Drydock Ave, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
Incident on Jul 17, 2022 (fatal): Employee is killed in fall while welding smoke stack
At 8:15 p.m. on July 17, 2022, an employee was preparing to weld inside a ship's smokestack while performing ship repair at a shipyard. The employee was standing on a plywood blank set 6 inches below the stack opening to prevent slag and debris from dropping down into the engine room. The plywood blank did not hold employee's weight and he fell 75 to 100 ft and was killed.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1b 29 CFR 1910.145(f)(3) · Specifications for accident prevention signs and tags |
Serious | $0 | $8,701 | Jan 9, 2023 | Final |
1670 Drydock Avenue Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Avenue Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Avenue Bldg 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
Incident on Jan 13, 2020 (fatal): Employee fractures skull when struck by sheared shackle and
At 4:15 p.m. on January 13, 2020, an employee was working with a load and was struck in the head by a sheared off shackle. The employee fractured his skull when struck by a sheared off shackle and was killed in a fall.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1915.152(a) · Personal Protective Equipment (PPE): general requirements |
Serious | $13,494 | $13,494 | Jun 10, 2020 | Final |
1670 Drydock Avenue Dry Dock #5, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
Incident on Dec 7, 2019: Employee burns finger in arc blast while removing cables
At 9:20 p.m. on December 7, 2019, an employee working as an Electrician for a shipyard was removing electrical cables from a power source. An arc blast occurred striking the employee. The employee sustained 2nd degree burns on his right index finger. The employee was transported to a burn unit, where he was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1915.89(g)(2) · Control of hazardous energy (lockout/tags-plus) |
Serious | $13,494 | $6,747 | Mar 24, 2020 | Final |
1670 Drydock Avenue Bldg 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Usns 1st Lt. Jack Lummus Main Yard, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
Incident on Apr 3, 2019 (fatal): Employee is struck and crushed by life boat davit arm
At 9:15 a.m. on April 3, 2019, Employee #1 was initiating the arc-welding to the davit #6 (a Harkrader Gravity Davit), manufactured by Marine Safety Equipment Corporation in 1985. The davit was located on the starboard side of the ship. When he setup the welder near the bottom of the davit, the wire rope holding the davit arm in place broke in two and the davit arm went from the "stowed" position to the swung-out position. When the wire rope broke, the davit arm swung down and struck the employee, killing him. According to the testing done by the Salt lake City Technical Center, the wire rope failed due to the electrical current that passed through it resulting in an electrical arc, which allowed the davit arm to swing down.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1915.56(c)(3) · Arc welding and cutting |
Serious | $13,260 | $8,619 | Sep 13, 2019 | Final |
| Citation 1, item 2 29 CFR 1915.116(f) · Use of gear |
Other-than-serious | $10,419 | $6,772 | Sep 13, 2019 | Final |
1670 Drydock Avenue Bldg 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Avenue Bldg 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
Incident on Nov 19, 2017: Employee is caught in stair tower and suffers multiple bone
At 1:00 p.m. on November 19, 2017, an employee was lifting the brow from a ship in a dry dock with a remote control hooked up to a tower crane and the brow moved in a forward direction. The employee fell off the brow onto the weathered deck of the ship and the employee was caught in the guard rails of the stair platform tower. The employee suffered multiple broken and fractured bones. The employee was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1915.117(b) · Qualifications of operators |
Serious | $6,911 | $3,455 | Mar 22, 2018 | Final |
1670 Drydock Ave Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Avenue Bldg 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Avenue Bldg 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Avenue Bldg 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.36(b)(1) · Exit route design |
Serious | $5,500 | $5,500 | May 29, 2015 | Final |
| Citation 1, item 1b 29 CFR 1910.36(d)(1) · Exit route design |
Serious | $5,500 | $0 | May 29, 2015 | Final |
| Citation 1, item 3a 29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks |
Serious | $7,000 | $5,600 | May 29, 2015 | Final |
| Citation 1, item 3b 29 CFR 1915.93(b)(3) · Motor vehicle safety equipment, operation and maintenance |
Serious | $0 | $0 | May 29, 2015 | Final |
| Citation 1, item 4 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $3,300 | $1,980 | May 29, 2015 | Final |
| Citation 1, item 5 29 CFR 1910.213(h)(4) · Woodworking machinery |
Serious | $5,500 | $4,400 | May 29, 2015 | Final |
| Citation 1, item 6a 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $3,300 | $3,300 | May 29, 2015 | Final |
| Citation 1, item 6b 29 CFR 1910.304(b)(2) · Grounding and circuit protection |
Serious | $0 | $0 | May 29, 2015 | Final |
| Citation 1, item 7 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Serious | $4,400 | $3,080 | May 29, 2015 | Final |
| Citation 1, item 8a 29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods |
Serious | $4,400 | $2,640 | May 29, 2015 | Final |
| Citation 1, item 8b 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | May 29, 2015 | Final |
| Citation 1, item 9 29 CFR 1910.305(j)(2)(vii) · Electrical wiring methods |
Serious | $4,400 | $3,080 | May 29, 2015 | Final |
| Citation 1, item 10 29 CFR 1915.56(b)(2) · Arc welding and cutting |
Serious | $3,300 | $3,300 | May 29, 2015 | Final |
| Citation 1, item 11 29 CFR 1915.56(e) · Arc welding and cutting |
Serious | $5,500 | $3,850 | May 29, 2015 | Final |
| Citation 1, item 12 29 CFR 1915.81(a)(3) · Housekeeping |
Serious | $5,500 | $4,400 | May 29, 2015 | Final |
| Citation 1, item 13 29 CFR 1915.81(a)(4) · Housekeeping |
Serious | $5,500 | $4,400 | May 29, 2015 | Final |
| Citation 2, item 1 29 CFR 1915.73(d) · Guarding of deck openings and edges |
Repeat | $38,500 | $23,100 | May 29, 2015 | Final |
| Citation 3, item 1 29 CFR 1910.37(b)(2) · Exit routes |
Other-than-serious | $0 | $0 | May 29, 2015 | Final |
1670 Drydock Ave Building 236 Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Avenue Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Avenue Building 236, Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Ave Building 236 Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.180(h)(3)(ix) · Crawler locomotive and truck cranes |
Serious | $7,000 | $4,200 | Sep 26, 2011 | Closed |
1670 Drydock Ave Building 236 Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1670 Drydock Ave Building 236 Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $3,400 | $2,210 | Jul 15, 2011 | Closed |
| Citation 1, item 1b 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Jul 15, 2011 | Closed |
| Citation 1, item 2 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $4,250 | $2,762 | Jul 15, 2011 | Closed |
| Citation 1, item 3 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $2,167 | $1,409 | Jul 15, 2011 | Closed |
| Citation 1, item 4 29 CFR 1915.71(j)(1) · Scaffolds or staging |
Serious | $4,250 | $2,762 | Jul 15, 2011 | Closed |
| Citation 1, item 5 29 CFR 1915.73(d) · Guarding of deck openings and edges |
Serious | $4,250 | $2,763 | Jul 15, 2011 | Closed |
| Citation 2, item 1 29 CFR 1915.132(d) · Portable electric tools |
Other-than-serious | $0 | $0 | Jul 15, 2011 | Closed |
1670 Drydock Ave Building 236 Suite 200, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Repeat | $200 | $200 | Jul 15, 2011 | Closed |
| Citation 1, item 1b 29 CFR 1910.1200(f)(5)(ii) · Hazard communication |
Repeat | $0 | $0 | Jul 15, 2011 | Closed |
| Citation 2, item 1 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Jul 15, 2011 | Closed |
| Citation 2, item 2 29 CFR 1910.107(g)(7) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Jul 15, 2011 | Closed |
| Citation 2, item 3 29 CFR 1910.134(k)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Jul 15, 2011 | Closed |
Debutante Project, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.24(f) · Fixed industrial stairs |
Serious | $1,083 | $758 | Oct 2, 2007 | Closed |
| Citation 1, item 2a 29 CFR 1910.95(d)(1) · Noise |
Serious | $1,700 | $1,190 | Oct 2, 2007 | Closed |
| Citation 1, item 2b 29 CFR 1910.95(g)(1) · Noise |
Serious | $0 | $0 | Oct 2, 2007 | Closed |
| Citation 1, item 2c 29 CFR 1910.95(k)(1) · Noise |
Serious | $0 | $0 | Oct 2, 2007 | Closed |
| Citation 1, item 3 29 CFR 1915.77(e) · Working surfaces |
Serious | $1,083 | $758 | Oct 2, 2007 | Closed |
| Citation 2, item 1a 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Oct 2, 2007 | Closed |
| Citation 2, item 1b 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Oct 2, 2007 | Closed |
| Citation 2, item 1c 29 CFR 1910.1200(f)(5)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Oct 2, 2007 | Closed |
Debutante Project, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(c)(5) · Spray painting and finishing |
Serious | $956 | $669 | Oct 10, 2007 | Closed |
| Citation 1, item 2 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $1,500 | $1,050 | Oct 10, 2007 | Closed |
| Citation 1, item 3 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $1,500 | $1,050 | Oct 10, 2007 | Closed |
| Citation 1, item 4 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $1,875 | $1,312 | Oct 10, 2007 | Closed |
| Citation 1, item 5 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $1,875 | $1,312 | Oct 10, 2007 | Closed |
| Citation 1, item 6 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Serious | $1,875 | $1,312 | Oct 10, 2007 | Closed |
| Citation 1, item 7 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $956 | $669 | Oct 10, 2007 | Closed |
| Citation 1, item 8 29 CFR 1910.334(a)(1) · Using electrical equipment |
Serious | $956 | $669 | Oct 10, 2007 | Closed |
| Citation 1, item 9a 29 CFR 1915.73(d) · Guarding of deck openings and edges |
Serious | $1,875 | $1,312 | Oct 10, 2007 | Closed |
| Citation 1, item 9b 29 CFR 1915.77(c) · Working surfaces |
Serious | $0 | $0 | Oct 10, 2007 | Closed |
| Citation 2, item 1 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Oct 10, 2007 | Closed |
| Citation 2, item 2 29 CFR 1910.304(a)(2) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Oct 10, 2007 | Closed |
| Citation 2, item 3 29 CFR 1915.91(a) · Accident prevention signs and tags |
Other-than-serious | $0 | $0 | Oct 10, 2007 | Closed |
Debutante Project, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1915.12(d)(4)(i) · Precautions and the order of testing before entering confined and enclosed spaces and other dangerous atmospheres |
Serious | $2,125 | $2,125 | May 1, 2006 | Closed |
| Citation 1, item 1b 29 CFR 1915.12(d)(2) · Precautions and the order of testing before entering confined and enclosed spaces and other dangerous atmospheres |
Serious | $0 | $0 | May 1, 2006 | Closed |
| Citation 1, item 2a 29 CFR 1915.15(b) · Maintenance of safe conditions |
Serious | $2,125 | $2,125 | May 1, 2006 | Closed |
| Citation 1, item 2b 29 CFR 1915.15(c) · Maintenance of safe conditions |
Serious | $0 | $0 | May 1, 2006 | Closed |
| Citation 2, item 1 29 CFR 1915.502(a) · Fire safety plan |
Other-than-serious | $0 | $0 | May 1, 2006 | Closed |
2383 Hwy 41, Mt Pleasant, SC 29466 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $1,875 | $1,300 | Jul 22, 2003 | Closed |
| Citation 1, item 1b 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $0 | $0 | Jul 22, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $1,500 | $1,000 | Jul 22, 2003 | Closed |
| Citation 1, item 3 29 CFR 1915.153(a)(3) · Eye and face protection |
Serious | $956 | $700 | Jul 22, 2003 | Closed |
2383 Hwy 41, Mt Pleasant, SC 29466 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(c)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 3 29 CFR 1910.134(e)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 4 29 CFR 1910.134(f)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 5 29 CFR 1910.134(g)(1)(ia) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 6 29 CFR 1910.134(h)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 7 29 CFR 1910.134(h)(2)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 8 29 CFR 1910.134(h)(3)(ia) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 9 29 CFR 1910.134(h)(4)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 10a 29 CFR 1910.134(i)(5)(iii) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 10b 29 CFR 1910.134(i)(5)(iv) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 11 29 CFR 1910.134(k)(5) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 12a 29 CFR 1910.141(d)(2)(ii) · Sanitation |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 12b 29 CFR 1910.141(d)(2)(iv) · Sanitation |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 13a 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 13b 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 13c 29 CFR 1910.1200(f)(5)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 13d 29 CFR 1910.1200(h)(2)(iv) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
Debutante Project, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes |
Serious | $956 | $670 | Jul 21, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.37(q)(2) · Exit routes |
Serious | $1,875 | $1,312 | Jul 21, 2003 | Closed |
| Citation 1, item 3 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $1,500 | $1,050 | Jul 21, 2003 | Closed |
| Citation 1, item 4 29 CFR 1910.213(c)(2) · Woodworking machinery |
Serious | $1,500 | $1,050 | Jul 21, 2003 | Closed |
| Citation 1, item 5 29 CFR 1910.213(h)(1) · Woodworking machinery |
Serious | $1,875 | $1,312 | Jul 21, 2003 | Closed |
| Citation 1, item 6 29 CFR 1910.213(h)(3) · Woodworking machinery |
Serious | $1,875 | $1,312 | Jul 21, 2003 | Closed |
| Citation 1, item 7 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $1,500 | $1,050 | Jul 21, 2003 | Closed |
| Citation 1, item 8a 29 CFR 1910.303(c) · Electrical equipment, general requirements |
Serious | $1,875 | $1,312 | Jul 21, 2003 | Closed |
| Citation 1, item 8b 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Jul 21, 2003 | Closed |
| Citation 1, item 9 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $1,875 | $1,312 | Jul 21, 2003 | Closed |
| Citation 1, item 10 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $1,875 | $1,312 | Jul 21, 2003 | Closed |
| Citation 1, item 11 29 CFR 1915.73(d) · Guarding of deck openings and edges |
Serious | $1,875 | $1,312 | Jul 21, 2003 | Closed |
| Citation 1, item 12 29 CFR 1915.73(e) · Guarding of deck openings and edges |
Serious | $1,875 | $1,312 | Jul 21, 2003 | Closed |
| Citation 1, item 13 29 CFR 1915.74(c)(2) · Access to vessels |
Serious | $956 | $670 | Jul 21, 2003 | Closed |
| Citation 1, item 14 29 CFR 1915.77(c) · Working surfaces |
Serious | $956 | $670 | Jul 21, 2003 | Closed |
| Citation 1, item 15 29 CFR 1915.153(a)(3) · Eye and face protection |
Serious | $956 | $670 | Jul 21, 2003 | Closed |
| Citation 2, item 1 29 CFR 1910.304(a)(2) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jul 21, 2003 | Closed |
| Citation 2, item 2 29 CFR 1915.56(e) · Arc welding and cutting |
Other-than-serious | $0 | $0 | Jul 21, 2003 | Closed |
| Citation 2, item 3 29 CFR 1915.91(a) · Accident prevention signs and tags |
Other-than-serious | $0 | $0 | Jul 21, 2003 | Closed |
Debutante Project, North Charleston, SC 29405 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(c)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.134(d)(1)(iii) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 3 29 CFR 1910.134(d)(3)(iiib)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 4 29 CFR 1910.134(f)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 5 29 CFR 1910.134(h)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 6 29 CFR 1910.134(k)(1)(vii) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 7 29 CFR 1910.134(k)(5) · Respiratory protection |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 8 29 CFR 1910.141(a)(3)(ii) · Sanitation |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 9a 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
| Citation 1, item 9b 29 CFR 1910.1200(f)(5)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 24, 2003 | Closed |
Debutante Project, North Charleston, SC 29405 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms |
Serious | $5,000 | $2,250 | Jul 2, 2002 | Closed |
Debutante Project, North Charleston, SC 29405 · OSHA's record · Phone and website on Google Maps
Incident on Nov 30, 1999 (fatal): Employee killed in fall from elevation
Employee #1 was on board a hopper barge trying to restore power to the temporary lighting located on the brow. Employee #1, working in the dark, climbed up upon the coaming between the port beam and the port bow. According to one eyewitness , Employee #1 then stood erect and stepped of the coaming, falling approximately 25 feet, 7 inches into the bottom of the empty hold. Employee #1 was pronounced dead at the hospital.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1915.73(c) · Guarding of deck openings and edges |
Serious | $5,000 | $5,000 | Apr 5, 2000 | Closed |
| Citation 1, item 1b 29 CFR 1915.73(e) · Guarding of deck openings and edges |
Serious | $0 | $0 | Apr 5, 2000 | Closed |
Debutante Project, North Charleston, SC 29405 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1915.14(a)(1)(ii) · Hot work |
Serious | $2,125 | $1,275 | Oct 19, 1999 | Closed |
| Citation 1, item 2 29 CFR 1915.116(p) · Use of gear |
Serious | $2,125 | $1,275 | Oct 19, 1999 | Closed |
| Citation 2, item 1 29 CFR 1910.1200(h) · Hazard communication |
Repeat | $200 | $120 | Oct 19, 1999 | Closed |
| Citation 3, item 1a 29 CFR 1915.12(d)(2) · Precautions and the order of testing before entering confined and enclosed spaces and other dangerous atmospheres |
Other-than-serious | $0 | $0 | Oct 19, 1999 | Closed |
| Citation 3, item 1b 29 CFR 1915.12(d)(3) · Precautions and the order of testing before entering confined and enclosed spaces and other dangerous atmospheres |
Other-than-serious | $0 | $0 | Oct 19, 1999 | Closed |
Debutante Project, North Charleston, SC 29405 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(b)(1) · Noise |
Serious | $2,125 | $2,125 | Jun 15, 1999 | Closed |
| Citation 1, item 2a 29 CFR 1910.95(d)(1) · Noise |
Serious | $2,125 | $2,125 | Jun 15, 1999 | Closed |
| Citation 1, item 2b 29 CFR 1910.95(g)(1) · Noise |
Serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 1, item 2c 29 CFR 1910.95(g)(5)(i) · Noise |
Serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 1, item 2d 29 CFR 1910.95(k)(1) · Noise |
Serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 1, item 3 29 CFR 1915.1030(g)(2)(iia) · Bloodborne pathogens |
Serious | $2,125 | $2,125 | Jun 15, 1999 | Closed |
| Citation 2, item 1 29 CFR 1910.95(l)(1) · Noise |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 2a 29 CFR 1910.134(c)(1)(ii) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 2b 29 CFR 1910.134(c)(1)(iii) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 2c 29 CFR 1910.134(c)(1)(v) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 2d 29 CFR 1910.134(c)(1)(vi) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 2e 29 CFR 1910.134(c)(1)(vii) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 2f 29 CFR 1910.134(c)(1)(ix) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 3 29 CFR 1910.134(d)(1)(iii) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 4 29 CFR 1910.134(d)(3)(iiib)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 5 29 CFR 1910.134(e)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 6 29 CFR 1910.134(f)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 7 29 CFR 1910.134(h)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 8 29 CFR 1910.134(k)(1)(vi) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 9 29 CFR 1910.134(k)(1)(vii) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 10 29 CFR 1910.134(k)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 11 29 CFR 1910.141(d)(2)(ii) · Sanitation |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 12 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 13 29 CFR 1910.1200(f)(5)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 14 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 15 29 CFR 1915.7(d)(2) · Competent person |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 16a 29 CFR 1915.1001(k)(2)(iib) · Asbestos |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 16b 29 CFR 1915.1001(k)(6) · Asbestos |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 16c 29 CFR 1915.1001(k)(8)(vii) · Asbestos |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
| Citation 2, item 16d 29 CFR 1915.1001(l)(4)(ii) · Asbestos |
Other-than-serious | $0 | $0 | Jun 15, 1999 | Closed |
Debutante Project, North Charleston, SC 29405 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.36(b)(4) · Exit route design |
Serious | $2,125 | $1,062 | Jul 16, 1999 | Closed |
| Citation 1, item 2 29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms |
Serious | $2,125 | $1,062 | Jul 16, 1999 | Closed |
| Citation 1, item 3a 29 CFR 1910.213(c)(2) · Woodworking machinery |
Serious | $1,700 | $850 | Jul 16, 1999 | Closed |
| Citation 1, item 3b 29 CFR 1910.213(c)(3) · Woodworking machinery |
Serious | $0 | $0 | Jul 16, 1999 | Closed |
| Citation 1, item 4 29 CFR 1910.213(h)(3) · Woodworking machinery |
Serious | $2,125 | $1,062 | Jul 16, 1999 | Closed |
| Citation 1, item 5a 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $1,700 | $850 | Jul 16, 1999 | Closed |
| Citation 1, item 5b 29 CFR 1915.134(b) · Abrasive wheels |
Serious | $0 | $0 | Jul 16, 1999 | Closed |
| Citation 1, item 6 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $2,125 | $1,062 | Jul 16, 1999 | Closed |
| Citation 1, item 7 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $2,125 | $1,062 | Jul 16, 1999 | Closed |
| Citation 1, item 8 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Serious | $2,125 | $1,062 | Jul 16, 1999 | Closed |
| Citation 2, item 1 29 CFR 1910.22(d)(1) · General requirements |
Other-than-serious | $850 | $425 | Jul 16, 1999 | Closed |
| Citation 2, item 2 29 CFR 1910.37(f)(6) · Exit routes |
Other-than-serious | $0 | $0 | Jul 16, 1999 | Closed |
| Citation 2, item 3 29 CFR 1910.37(q)(1) · Exit routes |
Other-than-serious | $0 | $0 | Jul 16, 1999 | Closed |
| Citation 2, item 4 29 CFR 1910.179(e)(4) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Jul 16, 1999 | Closed |
| Citation 2, item 5 29 CFR 1910.212(a)(1) · Machine guarding |
Other-than-serious | $0 | $0 | Jul 16, 1999 | Closed |
Debutante Project, North Charleston, SC 29405 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.305(j)(1)(i) · Electrical wiring methods |
Serious | $1,625 | $1,625 | Aug 12, 1997 | Closed |
| Citation 1, item 1b 29 CFR 1915.92(b)(1) · Retention of DOT markings, placards, and labels |
Serious | $0 | $0 | Aug 12, 1997 | Closed |
| Citation 1, item 2 29 CFR 1915.73(d) · Guarding of deck openings and edges |
Serious | $1,625 | $1,625 | Aug 12, 1997 | Closed |
| Citation 2, item 1 29 CFR 1915.71(b)(1) · Scaffolds or staging |
Other-than-serious | $0 | $0 | Aug 12, 1997 | Closed |
2383 Hwy 41, Mt Pleasant, SC 29466 · OSHA's record · Phone and website on Google Maps
Incident on Feb 4, 1995 (fatal): Employee falls from gangway and dies
Between 1:20 and 2:45 p.m., Employee #1 was working alone as a shipyard dock wat chman. One of Employee #1's duties was to ensure that the dry dock remained leve l and to operate the pumps to correct any listing. At approximately 2:45 p.m., E mployee #1 was found unconscious by his relief at the bottom of the dry dock. Em ployee #1 apparently fell 28 to 30 feet from the gangway that ran between the sh ip and the north wing wall. The gangway was found turned over on its west side. High winds of 42 to 46 mph may have contributed to the accident. The EMTs arrive d and found Employee #1 suffering from head and limb fractures and internal inju ries. He died at the hospital.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.27(d)(2) · Fixed ladders |
Serious | $1,500 | $600 | Apr 14, 1995 | Closed |
2383 Hwy 41, Mt Pleasant, SC 29466 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $1,500 | $750 | Jul 18, 1994 | Closed |
| Citation 1, item 1b 29 CFR 1915.134(b) · Abrasive wheels |
Serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 1, item 2a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $1,125 | $562 | Jul 18, 1994 | Closed |
| Citation 1, item 2b 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 1, item 3a 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $1,875 | $938 | Jul 18, 1994 | Closed |
| Citation 1, item 3b 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 1, item 4a 29 CFR 1910.305(d) · Electrical wiring methods |
Serious | $1,875 | $938 | Jul 18, 1994 | Closed |
| Citation 1, item 4b 29 CFR 1910.305(e)(1) · Electrical wiring methods |
Serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 1, item 5a 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Serious | $4,500 | $2,250 | Jul 18, 1994 | Closed |
| Citation 1, item 5b 29 CFR 1915.92(b)(2) · Retention of DOT markings, placards, and labels |
Serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 1, item 5c 29 CFR 1915.92(b)(3) · Retention of DOT markings, placards, and labels |
Serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 1, item 5d 29 CFR 1915.92(c) · Retention of DOT markings, placards, and labels |
Serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 1, item 6a 29 CFR 1910.253(b)(4)(i) · Gas welding and cutting |
Serious | $1,500 | $750 | Jul 18, 1994 | Closed |
| Citation 1, item 6b 29 CFR 1915.55(a)(9) · Gas welding and cutting |
Serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 1, item 7 29 CFR 1915.71(j)(1) · Scaffolds or staging |
Serious | $1,125 | $562 | Jul 18, 1994 | Closed |
| Citation 1, item 8 29 CFR 1915.71(k)(1) · Scaffolds or staging |
Serious | $1,500 | $750 | Jul 18, 1994 | Closed |
| Citation 1, item 9 29 CFR 1915.72(b)(7) · Ladders |
Serious | $1,500 | $750 | Jul 18, 1994 | Closed |
| Citation 1, item 10 29 CFR 1915.92(b)(1) · Retention of DOT markings, placards, and labels |
Serious | $1,875 | $938 | Jul 18, 1994 | Closed |
| Citation 1, item 11 29 CFR 1915.132(a) · Portable electric tools |
Serious | $1,875 | $938 | Jul 18, 1994 | Closed |
| Citation 2, item 1 29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 2, item 2 29 CFR 1910.24(f) · Fixed industrial stairs |
Other-than-serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 2, item 3 29 CFR 1910.67(c)(2)(ii) · Vehicle-mounted elevating and rotating work platforms |
Other-than-serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 2, item 4 29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms |
Other-than-serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 2, item 5 29 CFR 1910.213(c)(3) · Woodworking machinery |
Other-than-serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 2, item 6 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 2, item 7 29 CFR 1915.7(a)(2) · Competent person |
Other-than-serious | $0 | $0 | Jul 18, 1994 | Closed |
| Citation 2, item 8 29 CFR 1915.71(j)(5) · Scaffolds or staging |
Other-than-serious | $0 | $0 | Jul 18, 1994 | Closed |
2383 Hwy 41, Mt Pleasant, SC 29466 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(c)(1) · Noise |
Serious | $1,500 | $750 | Aug 1, 1994 | Closed |
| Citation 1, item 2a 29 CFR 1910.165(b)(2) · Employee alarm systems |
Serious | $1,500 | $750 | Aug 1, 1994 | Closed |
| Citation 1, item 2b 29 CFR 1910.165(b)(3) · Employee alarm systems |
Serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 1, item 3 29 CFR 1915.14(c) · Hot work |
Serious | $1,875 | $938 | Aug 1, 1994 | Closed |
| Citation 1, item 4a | Serious | $1,500 | $750 | Aug 1, 1994 | Closed |
| Citation 1, item 4b | Serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 1a 29 CFR 1910.134(a)(2) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 1b 29 CFR 1910.134(b)(5) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 1c 29 CFR 1910.134(b)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 1d 29 CFR 1910.134(b)(10) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 1e 29 CFR 1910.134(e)(5)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 2 29 CFR 1910.1030(c)(1)(i) · Bloodborne pathogens |
Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 3 29 CFR 1915.7(c)(1) · Competent person |
Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 4 | Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 5a | Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 5b | Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 5c | Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 6a | Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 6b | Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 7a | Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 7b | Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 8 29 CFR 1915.152(a)(1) · Personal Protective Equipment (PPE): general requirements |
Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
| Citation 2, item 9 29 CFR 1915.152(a)(2) · Personal Protective Equipment (PPE): general requirements |
Other-than-serious | $0 | $0 | Aug 1, 1994 | Closed |
2383 Hwy 41, Mt Pleasant, SC 29466 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2383 Hwy 41, Mt Pleasant, SC 29466 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Repeat | $400 | $400 | Apr 12, 1990 | Closed |
| Citation 2, item 1 29 CFR 1910.134(e)(5) · Respiratory protection |
Other-than-serious | $0 | $0 | Apr 12, 1990 | Closed |
| Citation 2, item 2 29 CFR 1915.152(a)(1) · Personal Protective Equipment (PPE): general requirements |
Other-than-serious | $0 | $0 | Apr 12, 1990 | Closed |
| Citation 2, item 3 29 CFR 1915.152(a)(2) · Personal Protective Equipment (PPE): general requirements |
Other-than-serious | $0 | $0 | Apr 12, 1990 | Closed |
2383 Hwy 41, Mt Pleasant, SC 29466 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $320 | $256 | May 8, 1990 | Closed |
| Citation 1, item 2 29 CFR 1910.133(a)(1) · Eye and face protection |
Serious | $160 | $128 | May 8, 1990 | Closed |
| Citation 1, item 3a 29 CFR 1910.179(j)(2) · Overhead and gantry cranes |
Serious | $240 | $192 | May 8, 1990 | Closed |
| Citation 1, item 3b 29 CFR 1910.179(j)(3) · Overhead and gantry cranes |
Serious | $0 | $0 | May 8, 1990 | Closed |
| Citation 1, item 4 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $160 | $128 | May 8, 1990 | Closed |
| Citation 1, item 5 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $560 | $448 | May 8, 1990 | Closed |
| Citation 1, item 6 29 CFR 1910.213(d)(1) · Woodworking machinery |
Serious | $400 | $320 | May 8, 1990 | Closed |
| Citation 1, item 7 29 CFR 1910.213(i)(1) · Woodworking machinery |
Serious | $400 | $320 | May 8, 1990 | Closed |
| Citation 1, item 8 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $240 | $192 | May 8, 1990 | Closed |
| Citation 1, item 9a 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $160 | $128 | May 8, 1990 | Closed |
| Citation 1, item 9b 29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | May 8, 1990 | Closed |
| Citation 1, item 10 29 CFR 1910.252(a)(2)(ivc) · Welding fire safety |
Serious | $160 | $128 | May 8, 1990 | Closed |
| Citation 1, item 11 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Serious | $480 | $384 | May 8, 1990 | Closed |
| Citation 1, item 12 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $320 | $256 | May 8, 1990 | Closed |
| Citation 1, item 13a 29 CFR 1915.74(a)(1) · Access to vessels |
Serious | $560 | $448 | May 8, 1990 | Closed |
| Citation 1, item 13b 29 CFR 1915.74(a)(2) · Access to vessels |
Serious | $0 | $0 | May 8, 1990 | Closed |
| Citation 1, item 14 29 CFR 1915.75(e) · Access to and guarding of dry docks and marine railways |
Serious | $480 | $384 | May 8, 1990 | Closed |
| Citation 1, item 15 29 CFR 1915.91(a) · Accident prevention signs and tags |
Serious | $240 | $192 | May 8, 1990 | Closed |
| Citation 1, item 16 29 CFR 1915.111(a) · Inspection |
Serious | $480 | $384 | May 8, 1990 | Closed |
| Citation 1, item 17 29 CFR 1915.154(c)(1) · Respiratory protection |
Serious | $480 | $384 | May 8, 1990 | Closed |
| Citation 2, item 1 29 CFR 1910.252(a)(2)(iid) · Welding fire safety |
Other-than-serious | $0 | $0 | May 8, 1990 | Closed |
| Citation 2, item 2 29 CFR 1915.55(a)(1) · Gas welding and cutting |
Other-than-serious | $0 | $0 | May 8, 1990 | Closed |
| Citation 2, item 3 29 CFR 1915.74(a)(10) · Access to vessels |
Other-than-serious | $0 | $0 | May 8, 1990 | Closed |
2383 Hwy 41, Mt Pleasant, SC 29466 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.94(d)(9)(vii) · Ventilation |
Other-than-serious | $0 | $0 | Mar 18, 1987 | Closed |
| Citation 1, item 2a 29 CFR 1910.134(b)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 18, 1987 | Closed |
| Citation 1, item 2b 29 CFR 1910.134(b)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 18, 1987 | Closed |
| Citation 1, item 3a 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 18, 1987 | Closed |
| Citation 1, item 3b 29 CFR 1910.1200(f)(4) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 18, 1987 | Closed |
| Citation 1, item 3c 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 18, 1987 | Closed |
| Citation 1, item 4 29 CFR 1915.7(c)(1) · Competent person |
Other-than-serious | $0 | $0 | Mar 18, 1987 | Closed |
2383 Hwy 41, Mt Pleasant, SC 29466 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.28(a)(2) · Safety requirements for scaffolding |
Serious | $400 | $400 | Mar 6, 1987 | Closed |
| Citation 2, item 1 29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Mar 6, 1987 | Closed |
| Citation 2, item 2 29 CFR 1910.133(a)(1) · Eye and face protection |
Other-than-serious | $0 | $0 | Mar 6, 1987 | Closed |
| Citation 2, item 3 29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Mar 6, 1987 | Closed |
| Citation 2, item 4 29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Mar 6, 1987 | Closed |
| Citation 2, item 5 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Mar 6, 1987 | Closed |
U S Highway 41 At Wando River, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 2, item 1 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 23, 1982 | Closed |
| Citation 2, item 2 | Other-than-serious | $0 | $0 | Mar 23, 1982 | Closed |
Hwy 41 At Wando River Bridge, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
U S Highway 41 At Wando River, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
U S Highway 41 At Wamdo River, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1915.56(a) · Arc welding and cutting |
Serious | $490 | $490 | Nov 14, 1978 | Closed |
| Citation 2, item 1 | Other-than-serious | $0 | $0 | Nov 14, 1978 | Closed |
U S Highway 41 At Wando River, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Us Highway 41 At Wando River B, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Us Highway 41 At Wandoriver Br, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(d)(2)(ii) · Respiratory protection |
Other-than-serious | $0 | $0 | Dec 21, 1977 | Closed |
U S Highway 41 At Wando River, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $200 | $200 | Dec 21, 1977 | Closed |
| Citation 1, item 2 29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts |
Serious | $150 | $150 | Dec 21, 1977 | Closed |
| Citation 2, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Dec 21, 1977 | Closed |
| Citation 2, item 2 29 CFR 1910.151(c) · First aid and eyewash |
Other-than-serious | $0 | $0 | Dec 21, 1977 | Closed |
| Citation 2, item 3 29 CFR 1910.184(e)(1) · Slings |
Other-than-serious | $0 | $0 | Dec 21, 1977 | Closed |
| Citation 2, item 4 29 CFR 1910.184(e)(3)(ii) · Slings |
Other-than-serious | $0 | $0 | Dec 21, 1977 | Closed |
| Citation 2, item 5 29 CFR 1910.212(a)(1) · Machine guarding |
Other-than-serious | $50 | $50 | Dec 21, 1977 | Closed |
| Citation 2, item 6 29 CFR 1910.213(h)(3) · Woodworking machinery |
Other-than-serious | $85 | $85 | Dec 21, 1977 | Closed |
| Citation 2, item 7 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Dec 21, 1977 | Closed |
| Citation 2, item 8 29 CFR 1910.242(b) · Hand and power tools |
Other-than-serious | $0 | $0 | Dec 21, 1977 | Closed |
| Citation 2, item 9 | Other-than-serious | $0 | $0 | Dec 21, 1977 | Closed |
| Citation 99, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Other-than-serious | $0 | $0 | Dec 24, 1977 | Closed |
U S Highway 41 At Wando River, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.36(b)(8) · Exit route design |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 2 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 3 29 CFR 1910.151(c) · First aid and eyewash |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 4 29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 5 29 CFR 1910.179(b)(5) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 6 29 CFR 1910.213(h)(1) · Woodworking machinery |
Other-than-serious | $40 | $40 | Sep 4, 1975 | Closed |
| Citation 1, item 7 29 CFR 1910.213(i)(1) · Woodworking machinery |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 8 29 CFR 1910.213(j)(4) · Woodworking machinery |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 9 29 CFR 1910.252(a)(2)(iid) · Welding fire safety |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 10 29 CFR 1910.252(a)(2)(vb)(7) · Welding fire safety |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 11 29 CFR 1910.252(e)(4)(v) · Welding fire safety |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 12 | Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 13 | Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 14 | Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 15 29 CFR 1915.35(a)(1) · Painting |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 16 29 CFR 1915.35(a)(2) · Painting |
Other-than-serious | $40 | $40 | Sep 4, 1975 | Closed |
| Citation 1, item 17 29 CFR 1915.35(a)(7) · Painting |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 18 29 CFR 1915.35(b)(3) · Painting |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 19 29 CFR 1915.36(b)(4) · Flammable liquids |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 20 | Other-than-serious | $40 | $40 | Sep 4, 1975 | Closed |
| Citation 1, item 21 | Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 22 | Other-than-serious | $55 | $55 | Sep 4, 1975 | Closed |
| Citation 1, item 23 29 CFR 1915.57(h) · Uses of fissionable material in ship repairing and shipbuilding |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 24 29 CFR 1915.71(f) · Scaffolds or staging |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 25 29 CFR 1915.72(a) · Ladders |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 26 29 CFR 1915.72(b) · Ladders |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 1, item 27 29 CFR 1915.81(c)(1) · Housekeeping |
Other-than-serious | $0 | $0 | Sep 4, 1975 | Closed |
| Citation 2, item 1 29 CFR 1910.212(a)(5) · Machine guarding |
Repeat | $45 | $45 | Sep 4, 1975 | Closed |
| Citation 3, item 1 | Repeat | $45 | $45 | Sep 4, 1975 | Closed |
Hwy 41 Charleston Co At Mandu, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.106(e)(2)(iib)(2) · Flammable liquids |
Other-than-serious | $0 | $0 | Apr 10, 1975 | Closed |
| Citation 1, item 2 29 CFR 1910.1001(g)(2)(i) · Asbestos in general industry |
Other-than-serious | $0 | $0 | Apr 10, 1975 | Closed |
| Citation 1, item 3 29 CFR 1910.1001(h)(1) · Asbestos in general industry |
Other-than-serious | $0 | $0 | Apr 10, 1975 | Closed |
| Citation 1, item 4 29 CFR 1910.1001(h)(2) · Asbestos in general industry |
Other-than-serious | $45 | $45 | Apr 10, 1975 | Closed |
| Citation 1, item 5 29 CFR 1910.1001(h)(1) · Asbestos in general industry |
Other-than-serious | $150 | $150 | Apr 10, 1975 | Closed |
| Citation 1, item 6 29 CFR 1910.178(g)(11) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Apr 10, 1975 | Closed |
| Citation 1, item 7 29 CFR 1910.134(f)(2)(ii) · Respiratory protection |
Other-than-serious | $0 | $0 | Apr 10, 1975 | Closed |
| Citation 1, item 8 29 CFR 1910.134(f)(2)(iv) · Respiratory protection |
Other-than-serious | $0 | $0 | Apr 10, 1975 | Closed |
| Citation 1, item 9 | Other-than-serious | $0 | $0 | Apr 10, 1975 | Closed |
Us 41 At Wando River Bridge Ch, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.157(a)(6) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Dec 20, 1974 | Closed |
| Citation 1, item 2 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Other-than-serious | $0 | $0 | Dec 20, 1974 | Closed |
| Citation 1, item 3 | Other-than-serious | $30 | $30 | Dec 20, 1974 | Closed |
Route 2 Box 180, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Other-than-serious | $0 | $0 | Jan 29, 1974 | Closed |
Route 2 Box 180, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Route 2 Box 180, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $700 | $700 | Jan 16, 1974 | Closed |
Route 2 Box 180, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Route 2 Box 180, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Route 2 Box 180, Mt Pleasant, SC 29464 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(5) · Machine guarding |
Other-than-serious | $0 | $0 | Nov 6, 1972 | Closed |
| Citation 1, item 2 29 CFR 1910.212(a)(1) · Machine guarding |
Other-than-serious | $0 | $0 | Nov 6, 1972 | Closed |
| Citation 1, item 3 29 CFR 1910.252(a)(2)(ivc) · Welding fire safety |
Other-than-serious | $30 | $30 | Nov 6, 1972 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the North Charleston site logged 5 recordable injuries or illnesses among about 250 workers: 1.9 per 100 full-time workers, against a median of 3.8 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Detyens Shipyards, Inc. North Charleston · 2025 | 250 | 5 | 0 | 1.9 | 3.8 |
| Detyens Shipyards Inc North Charleston · 2023 | 257 | 4 | 0 | 1.5 | 3.8 |
Included with any plan: 1 more yearly log from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansEmployers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 4 reports on file.
Dec 7, 2019, North Charleston: Hospitalization · electrocutions, electric shocks · body systems
An employee was removing electrical cables from an A-frame when an arc blast occurred, injuring one employee.
May 6, 2019, North Charleston: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.
An employee was using a bucket lift to work on the hull of a ship. The employee's hand was on the top of the bucket when the lift made contact with the hull of the ship and the employee's hand was caught between the bucket and the ship's hull. Two fingers were damaged and a third finger was medically amputated.
Nov 19, 2017, North Charleston: Hospitalization · fractures · leg(s), unspecified
The injured employee was lifting the brow from a ship in dry dock with a tower crane. The brow moved forward as it was lifted and caused a second employee to fall off the brow onto the weather deck of the ship. The falling employee struck the injured employee pushing the injured employee into the guardrails at the top of the stair platform tower resulting in fractures requiring hospitalization.
Mar 27, 2015, North Charleston: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.
An employee in the carpenter shop was ripping 2x4's into to smaller slats when they made contact with the blade, resulting in the amputation of finger(s).
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1001(g)(2)(i)
(2) Respirator program. (i) The employer must implement a respiratory protection program in accordance with 29 CFR 134 (b) through (d) (except (d)(1)(iii)), and (f) through (m), which covers each employee required by this section to use a respirator.
29 CFR 1910.1001(h)(1)
(h) Protective work clothing and equipment—(1) Provision and use. If an employee is exposed to asbestos above the TWA and/or excursion limit, or where the possibility of eye irritation exists, the employer shall provide at no cost to the employee and ensure that the employee uses appropriate protective work clothing and equipment such as, but not limited to:
29 CFR 1910.1001(h)(2)
(h) High dispersion index of refraction oils (Special for dispersion staining.)
Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.