OSHA SearchOSHA records by employer

Grede Wisconsin Subsidiaries LLC: OSHA inspections and violations

Browntown, Wisconsin · Iron Foundries · NAICS 331511

38inspections
281citation items
$438,968current penalties
Nov 1, 2023last inspection

Since 1988, OSHA inspectors have visited Grede Wisconsin Subsidiaries LLC in Wisconsin 38 times.

The most recent inspection opened on Nov 1, 2023 after a complaint, in Browntown.

In all, OSHA issued 281 citation items: 218 serious, 12 repeat and 51 other-than-serious.

The proposed penalties came to $740,298; today they stand at $438,968, 41% less.

The rule cited most here is 1910.134 (respiratory protection), 40 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Grede Wisconsin Subsidiaries LLC averages $9,208 across 1 cited inspection.

Grede Wisconsin Subsidiaries LLC also files yearly injury logs with OSHA, summarized below.

It reported 4 severe injuries to OSHA since 2015.

Grede Wisconsin Subsidiaries LLC: OSHA citation items per year, 1988 to 2023
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

216employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Grede Wisconsin Subsidiaries LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347075673 OPENED NOV 1, 2023Closed

Complaint · Partial · Health · 140 employees at the site · Closed Feb 15, 2024

N2480 County Highway M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346290315 OPENED OCT 19, 2022Closed

Referral · Partial · Safety · 133 employees at the site · Closed Apr 24, 2023

N2480 County Road M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$12,278$9,208Feb 28, 2023Final
Citation 2, item 1
29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Feb 28, 2023Final

Inspection 340001601 OPENED OCT 10, 2014Closed

Complaint · Partial · Health · 200 employees at the site · Closed Aug 1, 2016

N2480 Cty Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$7,000$5,000Apr 9, 2015Final
Citation 2, item 1
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Repeat$38,500$31,000Apr 9, 2015Final
Citation 2, item 2
29 CFR 1910.134(k)(1)(ii) · Respiratory protection
Repeat$38,500$31,000Apr 9, 2015Final
Citation 2, item 3
29 CFR 1910.1200(h)(1) · Hazard communication
Repeat$38,500$31,000Apr 9, 2015Final

Inspection 339912214 OPENED AUG 25, 2014Closed

Complaint · Partial · Safety · 183 employees at the site · Closed Oct 15, 2014

242 Pearl Street, Berlin, WI 54923 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$2,805$2,805Sep 4, 2014Final
Citation 1, item 2
29 CFR 1910.334(a)(3)(i) · Using electrical equipment
Other-than-serious$2,805$0Sep 4, 2014Final

Inspection 339841504 OPENED JUL 7, 2014Closed

Monitoring · Partial · Health · 150 employees at the site · Closed Aug 1, 2014

N2480 Cty Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339644528 OPENED MAR 31, 2014Closed

Monitoring · Partial · Health · 212 employees at the site · Closed Apr 3, 2014

242 S. Pearl St, Berlin, WI 54923 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339474777 OPENED NOV 6, 2013Closed

Complaint · Partial · Health · 170 employees at the site · Closed Jan 5, 2016

N2480 Cty Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.27(d)(1)(iv) · Fixed ladders
Serious$5,500$3,000Mar 20, 2014Final
Citation 1, item 2
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$6,600$3,300Mar 20, 2014Final
Citation 2, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Repeat$38,500$22,500Mar 20, 2014Final

Inspection 339427908 OPENED SEP 27, 2013Closed

Monitoring · Partial · Health · 608 employees at the site · Closed Oct 30, 2013

700 Ash Street, Reedsburg, WI 53959 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

30 older inspections

Inspection 339175853 OPENED JUL 11, 2013Closed

Follow-up · Partial · Health · 173 employees at the site · Closed Sep 9, 2013

N2480 Cty Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339020604 OPENED APR 23, 2013Closed

Complaint · Partial · Health · 200 employees at the site · Closed Jan 31, 2014

N2480 Cty Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 337649263 OPENED NOV 30, 2012Closed

Monitoring · Partial · Health · 150 employees at the site · Closed Feb 28, 2013

County M & Highway 11, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 336493382 OPENED SEP 21, 2012Closed

Planned · Complete · Health · 600 employees at the site · Closed Jul 2, 2013

700 Ash Street, Reedsburg, WI 53959 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 336535398 OPENED SEP 21, 2012Closed

Monitoring · Partial · Health · 600 employees at the site · Closed Mar 19, 2013

700 Ash Street, Reedsburg, WI 53959 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 335518999 OPENED AUG 1, 2012Closed

Planned · Complete · Health · 204 employees at the site · Closed Jul 2, 2013

N2480 Cty Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.22(a)(1) · General requirements
Serious$5,500$5,500Feb 1, 2013Final
Citation 1, item 1b
29 CFR 1910.24(f) · Fixed industrial stairs
Serious$5,500$0Feb 1, 2013Final
Citation 1, item 2
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Serious$5,500$5,500Feb 1, 2013Final
Citation 1, item 4a
29 CFR 1910.27(b)(1)(iii) · Fixed ladders
Serious$7,000$7,000Feb 1, 2013Final
Citation 1, item 4c
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Feb 1, 2013Final
Citation 1, item 5
29 CFR 1910.28(a)(1) · Safety requirements for scaffolding
Serious$7,000$7,000Feb 1, 2013Final
Citation 1, item 6a Other-than-serious$6,600$5,000Feb 1, 2013Final
Citation 1, item 6b
29 CFR 1910.94(a)(7) · Ventilation
Other-than-serious$0$0Feb 1, 2013Final
Citation 1, item 7b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$7,000Feb 1, 2013Final
Citation 1, item 7c
29 CFR 1910.138(a) · Gloves and hand protection
Serious$0$0Feb 1, 2013Final
Citation 1, item 8a
29 CFR 1910.134(d)(1)(i) · Respiratory protection
Serious$7,000$6,000Feb 1, 2013Final
Citation 1, item 8b
29 CFR 1910.134(d)(3)(i)(b)(1) · Respiratory protection
Serious$0$0Feb 1, 2013Final
Citation 1, item 8c
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$7,000$0Feb 1, 2013Final
Citation 1, item 10
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$7,000$6,000Feb 1, 2013Final
Citation 1, item 12a
29 CFR 1910.134(f)(5) · Respiratory protection
Serious$7,000$6,000Feb 1, 2013Final
Citation 1, item 12b
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$0$0Feb 1, 2013Final
Citation 1, item 12c
29 CFR 1910.134(k)(1)(ii) · Respiratory protection
Serious$7,000$0Feb 1, 2013Final
Citation 1, item 14b
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Serious$0$7,000Feb 1, 2013Final
Citation 1, item 14c
29 CFR 1910.146(d)(1) · Permit-required confined spaces
Serious$7,000$0Feb 1, 2013Final
Citation 1, item 16a
29 CFR 1910.146(d)(3) · Permit-required confined spaces
Serious$7,000$6,000Feb 1, 2013Final
Citation 1, item 16b
29 CFR 1910.146(d)(4)(i) · Permit-required confined spaces
Serious$0$0Feb 1, 2013Final
Citation 1, item 16c
29 CFR 1910.146(d)(4)(v) · Permit-required confined spaces
Serious$0$0Feb 1, 2013Final
Citation 1, item 16d
29 CFR 1910.146(d)(4)(viii) · Permit-required confined spaces
Serious$0$0Feb 1, 2013Final
Citation 1, item 16e
29 CFR 1910.146(d)(5)(i) · Permit-required confined spaces
Serious$0$0Feb 1, 2013Final
Citation 1, item 16f
29 CFR 1910.146(d)(6) · Permit-required confined spaces
Serious$0$0Feb 1, 2013Final
Citation 1, item 16g
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Serious$7,000$0Feb 1, 2013Final
Citation 1, item 16h
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$7,000$0Feb 1, 2013Final
Citation 1, item 19a Serious$7,000$7,000Feb 1, 2013Final
Citation 1, item 19b Serious$0$0Feb 1, 2013Final
Citation 1, item 19c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$7,000$0Feb 1, 2013Final
Citation 1, item 19d
29 CFR 1910.147(d)(3) · Lockout/tagout
Serious$7,000$0Feb 1, 2013Final
Citation 1, item 19e
29 CFR 1910.147(d)(5)(i) · Lockout/tagout
Serious$0$0Feb 1, 2013Final
Citation 1, item 19f
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$38,500$0Feb 1, 2013Final
Citation 1, item 22
29 CFR 1910.178(l)(4)(ii)(b) · Forklifts and other powered industrial trucks
Other-than-serious$5,500$5,000Feb 1, 2013Final
Citation 1, item 23
29 CFR 1910.22(b)(1) · General requirements
Serious$4,400$4,500Feb 1, 2013Final
Citation 1, item 24a
29 CFR 1910.1020(e)(1)(i) · Access to employee exposure and medical records
Other-than-serious$7,000$5,000Feb 1, 2013Final
Citation 1, item 24c
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Feb 1, 2013Final
Citation 2, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$38,500$5,000Feb 1, 2013Final
Citation 2, item 3a
29 CFR 1910.1000(c) · Air contaminants
Repeat$38,500$38,500Feb 1, 2013Final
Citation 2, item 3b
29 CFR 1910.1000(e) · Air contaminants
Repeat$0$0Feb 1, 2013Final
Citation 3, item 1
29 CFR 1910.1020(e)(3)(i) · Access to employee exposure and medical records
Other-than-serious$0$0Feb 1, 2013Final

Inspection 334355112 OPENED MAY 17, 2012Closed

Complaint · Partial · Safety · 314 employees at the site · Closed Aug 23, 2013

242 S Pearl St, Berlin, WI 54923 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$5,500$2,250Nov 13, 2012Final
Citation 1, item 2b
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$0$0Nov 13, 2012Final
Citation 1, item 3
29 CFR 1910.36(h)(3) · Exit route design
Other-than-serious$3,300$0Nov 13, 2012Final
Citation 1, item 4a
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Serious$5,500$2,250Nov 13, 2012Final
Citation 1, item 5a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,400$2,200Nov 13, 2012Final
Citation 1, item 5b
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 13, 2012Final
Citation 1, item 6a
29 CFR 1910.303(b)(1)(viii) · Electrical equipment, general requirements
Serious$5,500$2,500Nov 13, 2012Final
Citation 1, item 6b
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Nov 13, 2012Final
Citation 1, item 7
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$5,500$0Nov 13, 2012Final
Citation 2, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Repeat$22,000$7,000Nov 13, 2012Final
Citation 2, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Repeat$220$220Nov 13, 2012Final

Inspection 331113019 OPENED JAN 19, 2012Closed

Complaint · Partial · Health · 315 employees at the site · Closed Jul 5, 2012

242 S. Pearl St, Berlin, WI 54923 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1001(g)(3)(i) · Asbestos in general industry
Serious$4,000$2,800Jun 13, 2012Final
Citation 1, item 1b
29 CFR 1910.1001(j)(2)(i) · Asbestos in general industry
Serious$0$0Jun 13, 2012Final

Inspection 315288209 OPENED APR 26, 2011Closed

Complaint · Partial · Health · 350 employees at the site · Closed May 18, 2012

242 S Pearl St, Berlin, WI 54923 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Jul 28, 2011Closed

Inspection 313136228 OPENED NOV 23, 2010Closed

Monitoring · Partial · Health · 156 employees at the site · Closed Nov 23, 2010

N2480 County Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312557911 OPENED AUG 5, 2010Closed

Complaint · Complete · Safety · 263 employees at the site · Closed Nov 26, 2014

242 S Pearl St, Berlin, WI 54923 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(c) · General requirements
Serious$2,250$1,500Nov 15, 2010Closed
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$1,800$1,100Nov 15, 2010Closed
Citation 1, item 3
29 CFR 1910.26(c)(1)(iv) · Portable metal ladders
Serious$1,350$900Nov 15, 2010Closed
Citation 1, item 4
29 CFR 1910.36(d)(1) · Exit route design
Serious$2,250$1,100Nov 15, 2010Closed
Citation 1, item 5a
29 CFR 1910.106(e)(9)(iv) · Flammable liquids
Other-than-serious$1,800$0Nov 15, 2010Closed
Citation 1, item 5b
29 CFR 1910.110(b)(6)(vi) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Nov 15, 2010Closed
Citation 1, item 6a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$4,500$3,000Nov 15, 2010Closed
Citation 1, item 6b
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$0$0Nov 15, 2010Closed
Citation 1, item 6d
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Nov 15, 2010Closed
Citation 1, item 7a
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$2,250$1,100Nov 15, 2010Closed
Citation 1, item 7b
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$0$0Nov 15, 2010Closed
Citation 1, item 7c
29 CFR 1910.147(e)(3) · Lockout/tagout
Serious$0$0Nov 15, 2010Closed
Citation 1, item 8
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$1,350$700Nov 15, 2010Closed
Citation 1, item 9
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,250$1,100Nov 15, 2010Closed
Citation 1, item 10
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$4,500$3,500Nov 15, 2010Closed
Citation 1, item 11b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$1,300Nov 15, 2010Closed
Citation 1, item 11d
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Nov 15, 2010Closed
Citation 1, item 12a
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$1,800$900Nov 15, 2010Closed
Citation 1, item 12b
29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 15, 2010Closed
Citation 1, item 13a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$2,250$1,300Nov 15, 2010Closed
Citation 1, item 13b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 15, 2010Closed
Citation 1, item 14
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$2,250$1,300Nov 15, 2010Closed
Citation 1, item 15
29 CFR 1910.242(b) · Hand and power tools
Serious$1,350$900Nov 15, 2010Closed
Citation 1, item 16a
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$1,800$1,200Nov 15, 2010Closed
Citation 1, item 16b
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$0$0Nov 15, 2010Closed
Citation 1, item 17a
29 CFR 1910.304(c)(4) · Grounding and circuit protection
Serious$4,500$2,250Nov 15, 2010Closed
Citation 1, item 17b
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$0$0Nov 15, 2010Closed
Citation 1, item 18
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$2,250$1,100Nov 15, 2010Closed
Citation 1, item 19a Serious$2,250$1,100Nov 15, 2010Closed
Citation 1, item 19b
29 CFR 1910.333(b)(2)(i) · Working near live electrical parts
Serious$0$0Nov 15, 2010Closed
Citation 1, item 19c
29 CFR 1910.334(c)(1) · Using electrical equipment
Serious$0$0Nov 15, 2010Closed
Citation 1, item 20a
29 CFR 1910.335(a)(1)(ii) · Safeguards for personnel protection
Serious$4,500$3,000Nov 15, 2010Closed
Citation 1, item 20b
29 CFR 1910.335(a)(2)(i) · Safeguards for personnel protection
Serious$0$0Nov 15, 2010Closed
Citation 1, item 21a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$1,350$800Nov 15, 2010Closed
Citation 1, item 21b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$0$0Nov 15, 2010Closed

Inspection 312557929 OPENED AUG 5, 2010Closed

Complaint · Complete · Health · 320 employees at the site · Closed Dec 1, 2012

242 S Pearl St, Berlin, WI 54923 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,250$1,200Jan 21, 2011Closed
Citation 1, item 2a
29 CFR 1910.120(q)(6)(ia) · Hazardous waste operations and emergency response
Serious$1,800$1,100Jan 21, 2011Closed
Citation 1, item 2b
29 CFR 1910.120(q)(6)(v) · Hazardous waste operations and emergency response
Serious$0$0Jan 21, 2011Closed
Citation 1, item 3a
29 CFR 1910.134(c)(3) · Respiratory protection
Serious$1,800$1,800Jan 21, 2011Closed
Citation 1, item 3b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$1,800$0Jan 21, 2011Closed
Citation 1, item 3c
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$1,800$0Jan 21, 2011Closed
Citation 1, item 3d
29 CFR 1910.134(h)(4)(ii) · Respiratory protection
Serious$0$0Jan 21, 2011Closed
Citation 1, item 6
29 CFR 1910.134(i)(7) · Respiratory protection
Serious$1,800$1,200Jan 21, 2011Closed
Citation 1, item 7a
29 CFR 1910.146(c)(7)(i) · Permit-required confined spaces
Serious$2,250$1,250Jan 21, 2011Closed
Citation 1, item 7b
29 CFR 1910.146(c)(7)(iii) · Permit-required confined spaces
Serious$0$0Jan 21, 2011Closed
Citation 1, item 8a
29 CFR 1910.1048(m)(5) · Formaldehyde
Serious$1,350$750Jan 21, 2011Closed
Citation 1, item 8b Serious$0$0Jan 21, 2011Closed
Citation 2, item 1 Other-than-serious$0$0Jan 21, 2011Closed

Inspection 313130288 OPENED SEP 9, 2009Closed

Monitoring · Partial · Health · 125 employees at the site · Closed Sep 10, 2009

N2480 County Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310769112 OPENED JAN 6, 2009Closed

Follow-up · Partial · Health · 220 employees at the site · Closed Aug 28, 2013

N2480 County Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$5,000$3,000Apr 27, 2009Closed
Citation 1, item 3 Serious$2,500$1,500Apr 27, 2009Closed
Citation 1, item 4a
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$2,500$1,500Apr 27, 2009Closed
Citation 1, item 4b
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$0$0Apr 27, 2009Closed
Citation 1, item 4c
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Apr 27, 2009Closed
Citation 1, item 5a
29 CFR 1910.1000(c) · Air contaminants
Serious$2,500$1,500Apr 27, 2009Closed
Citation 1, item 5b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Apr 27, 2009Closed

Inspection 308387117 OPENED OCT 31, 2006Closed

Referral · Complete · Health · 230 employees at the site · Closed Oct 14, 2011

N2480 County Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.37(a)(2) · Exit routes
Serious$2,500$1,500Mar 5, 2007Closed
Citation 1, item 5a
29 CFR 1910.146(d)(4)(ix) · Permit-required confined spaces
Serious$1,000$1,000Mar 5, 2007Closed
Citation 1, item 7
29 CFR 1910.176(b) · Material storage and aisles
Serious$3,500$3,500Mar 5, 2007Closed
Citation 1, item 12
29 CFR 1910.1200(h) · Hazard communication
Serious$4,000$4,000Mar 5, 2007Closed
Citation 3, item 1
29 CFR 1910.110(b)(6)(vi) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Mar 5, 2007Closed
Citation 3, item 2
29 CFR 1910.134(i)(1)(iid) · Respiratory protection
Other-than-serious$0$0Mar 5, 2007Closed
Citation 4, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$0$2,500Mar 5, 2007Closed
Citation 4, item 1b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Mar 5, 2007Closed
Citation 4, item 1c
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$0$0Mar 5, 2007Closed
Citation 4, item 1d
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Mar 5, 2007Closed
Citation 4, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$5,000$5,000Mar 5, 2007Closed
Citation 4, item 2b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Mar 5, 2007Closed
Citation 4, item 2c
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$0$0Mar 5, 2007Closed
Citation 4, item 2d
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Mar 5, 2007Closed
Citation 4, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$3,500$3,500Mar 5, 2007Closed
Citation 4, item 3b
29 CFR 1910.134(d)(1)(i) · Respiratory protection
Serious$0$0Mar 5, 2007Closed
Citation 4, item 3c
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Mar 5, 2007Closed
Citation 4, item 3d
29 CFR 1910.1000(c) · Air contaminants
Serious$0$0Mar 5, 2007Closed
Citation 4, item 4a
29 CFR 1910.1000(c) · Air contaminants
Serious$0$2,000Mar 5, 2007Closed
Citation 4, item 4b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Mar 5, 2007Closed
Citation 4, item 5a
29 CFR 1910.1025(d)(2) · Lead in general industry
Serious$0$3,500Mar 5, 2007Closed
Citation 4, item 5b
29 CFR 1910.1025(l)(1)(i) · Lead in general industry
Serious$0$0Mar 5, 2007Closed

Inspection 306113663 OPENED NOV 24, 2004Closed

Referral · Partial · Safety · 240 employees at the site · Closed Jan 5, 2005

N2480 Cty Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306107038 OPENED AUG 8, 2003Closed

Complaint · Partial · Safety · 197 employees at the site · Closed Sep 25, 2003

N2480 County Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Incident on Aug 6, 2003: Machine traps employee between guard and control panel

At approximately 1:20 a.m. on August 6, 2003, Employee #1 was working in Core Ro om 1. Employee #1 was caught between the Redford 23 control panel and the guard behind the core box. While the machine was in operation and the box was closed t he distance measured 14 in. wide. The depth from the cylinder to the outer cover was 9 in. wide. The core making operation was activated with two-handed control s. However, once the box closed with the core inside, the operator could remove his hands from the controls. Employee #1 was caught at the point when the core b ox opened. Employee #1 was found in an upright position with his back against th e control panel and his chest against the box guard. Employee #1 sustained a che st injury with fractured ribs and a pneumo-thorax (accumulation of air or gas in the pleural cavity) and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(2) · Machine guarding
Serious$2,000$700Aug 26, 2003Closed

Inspection 306105503 OPENED APR 22, 2003Closed

Follow-up · Partial · Safety · 150 employees at the site · Closed Apr 23, 2003

N2480 County Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306104712 OPENED FEB 14, 2003Closed

Monitoring · Partial · Health · 250 employees at the site · Closed Feb 19, 2003

N2480 County Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306104720 OPENED FEB 14, 2003Closed

Follow-up · Partial · Health · 250 employees at the site · Closed Apr 1, 2003

N2480 County Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306104738 OPENED FEB 14, 2003Closed

Monitoring · Partial · Health · 250 employees at the site · Closed Apr 1, 2003

N2480 County Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303864623 OPENED OCT 12, 2001Closed

Follow-up · Complete · Health · 150 employees at the site · Closed Oct 10, 2014

N2480 County Hwy M, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(a)(1) · Respiratory protection
Serious$2,500$2,500Feb 6, 2002Closed

Inspection 303864664 OPENED OCT 12, 2001Closed

Follow-up · Partial · Safety · 150 employees at the site · Closed Dec 17, 2001

N2480 County Hwy M, Browntown, WI 53522 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Other-than-serious$2,500$0Nov 14, 2001Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$2,500$0Nov 14, 2001Closed
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$2,500$2,500Nov 14, 2001Closed
Citation 1, item 6
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$2,500$0Nov 14, 2001Closed
Citation 1, item 7a
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$0$2,500Nov 28, 2001Closed
Citation 1, item 7b
29 CFR 1910.147(f)(3)(ii) · Lockout/tagout
Serious$0$0Nov 28, 2001Closed
Citation 2, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Repeat$12,500$8,750Nov 14, 2001Closed

Inspection 303860324 OPENED NOV 6, 2000Closed

Complaint · Partial · Health · 225 employees at the site · Closed Jan 6, 2001

N2480 County Hwy M, Browntown, WI 53522 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300567450 OPENED FEB 10, 1999Closed

Planned · Complete · Health · 260 employees at the site · Closed Mar 18, 2016

County M & Highway 11, Browntown, WI 53522 · Iron Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
OSH Act Section 5(a)(1) · General Duty Clause
Serious$4,500$2,300Aug 6, 1999Final
Citation 1, item 3
29 CFR 1910.22(a)(1) · General requirements
Serious$3,150$1,575Aug 6, 1999Final
Citation 1, item 5a
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$2,250$1,125Aug 6, 1999Final
Citation 1, item 5b
29 CFR 1910.23(c)(3) · Guarding floor and wall openings and holes
Serious$0$0Aug 6, 1999Final
Citation 1, item 8a Serious$3,150$1,575Aug 6, 1999Final
Citation 1, item 8b
29 CFR 1910.94(a)(7) · Ventilation
Serious$0$0Aug 6, 1999Final
Citation 1, item 11a
29 CFR 1910.106(e)(3)(va) · Flammable liquids
Serious$4,500$2,300Aug 6, 1999Final
Citation 1, item 11b
29 CFR 1910.108(b)(1) · [Reserved]
Serious$0$0Aug 6, 1999Final
Citation 1, item 11c
29 CFR 1910.108(c)(5) · [Reserved]
Serious$0$0Aug 6, 1999Final
Citation 1, item 11d
29 CFR 1910.108(f)(3) · [Reserved]
Serious$0$0Aug 6, 1999Final
Citation 1, item 11e Serious$0$0Aug 6, 1999Final
Citation 1, item 13
29 CFR 1910.120(q)(6) · Hazardous waste operations and emergency response
Serious$4,500$2,300Aug 6, 1999Final
Citation 1, item 21a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$4,500$1,000Aug 6, 1999Final
Citation 1, item 21b
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$0$0Aug 6, 1999Final
Citation 1, item 22
29 CFR 1910.151(c) · First aid and eyewash
Serious$3,150$1,575Aug 6, 1999Final
Citation 1, item 23
29 CFR 1910.176(b) · Material storage and aisles
Serious$2,250$1,125Aug 6, 1999Final
Citation 1, item 25
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,500$2,300Aug 6, 1999Final
Citation 1, item 29
29 CFR 1910.243(b)(1) · Guarding of portable powered tools
Serious$3,150$1,575Aug 6, 1999Final
Citation 1, item 33a
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$4,500$2,300Aug 6, 1999Final
Citation 1, item 33b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Aug 6, 1999Final
Citation 1, item 35a
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$6,300$3,150Aug 6, 1999Final
Citation 1, item 35b
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$0$0Aug 6, 1999Final
Citation 1, item 35c
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Aug 6, 1999Final
Citation 1, item 36
29 CFR 1910.1020(g)(1) · Access to employee exposure and medical records
Serious$2,250$1,125Aug 6, 1999Final
Citation 1, item 38
29 CFR 1910.1200(h) · Hazard communication
Serious$4,500$2,300Aug 6, 1999Final
Citation 1, item 39a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$2,300$2,300Aug 30, 1999Closed
Citation 1, item 39b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Aug 30, 1999Closed
Citation 1, item 39c
29 CFR 1910.178(c)(1) · Forklifts and other powered industrial trucks
Serious$0$0Aug 6, 1999Closed
Citation 1, item 40a
29 CFR 1910.134(d)(1)(i) · Respiratory protection
Serious$2,300$2,300Aug 6, 1999Final
Citation 1, item 40b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Aug 6, 1999Final
Citation 1, item 40c
29 CFR 1910.134(k)(1)(i) · Respiratory protection
Serious$0$0Aug 30, 1999Closed
Citation 1, item 41a
29 CFR 1910.303(b)(1)(vii) · Electrical equipment, general requirements
Serious$2,300$2,300Aug 30, 1999Closed
Citation 1, item 41b
29 CFR 1910.304(f)(5)(iva) · Grounding and circuit protection
Serious$0$0Aug 30, 1999Closed
Citation 1, item 42a
29 CFR 1910.1000(c) · Air contaminants
Serious$3,150$3,150Aug 6, 1999Closed
Citation 1, item 42b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Aug 6, 1999Closed
Citation 2, item 1
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Aug 6, 1999Final
Citation 2, item 2
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Aug 6, 1999Final
Citation 2, item 3
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 6, 1999Final
Citation 2, item 4
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Other-than-serious$4,500$0Aug 6, 1999Final
Citation 2, item 5
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0Aug 6, 1999Final
Citation 2, item 6
29 CFR 1910.133(a)(1) · Eye and face protection
Other-than-serious$1,125$1,125Aug 6, 1999Final
Citation 2, item 7a
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$0$0Aug 6, 1999Final
Citation 2, item 7b
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0Aug 6, 1999Final
Citation 2, item 8
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$1,175$1,175Aug 6, 1999Final
Citation 2, item 9
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Aug 6, 1999Final
Citation 2, item 10
29 CFR 1910.1000(a)(2) · Air contaminants
Other-than-serious$0$0Aug 6, 1999Final
Citation 2, item 11a
29 CFR 1910.1000(c) · Air contaminants
Other-than-serious$0$0Aug 6, 1999Final
Citation 2, item 11b
29 CFR 1910.1000(e) · Air contaminants
Other-than-serious$0$0Aug 6, 1999Final
Citation 2, item 11c Other-than-serious$0$0Aug 6, 1999Final
Citation 2, item 11d Other-than-serious$0$0Aug 30, 1999Final
Citation 3, item 1
29 CFR 1910.1000(c) · Air contaminants
Repeat$5,000$5,000Dec 4, 2002Final

Inspection 105940118 OPENED MAY 4, 1994Closed

Complaint · Partial · Safety · 250 employees at the site · Closed Jul 1, 1994

N2480 Cty Hwy M, Browntown, WI 53522 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.242(a) · Hand and power tools
Serious$1,500$900May 11, 1994Closed
Citation 1, item 1b
29 CFR 1910.243(c)(2) · Guarding of portable powered tools
Serious$0$0May 11, 1994Closed
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0May 11, 1994Closed
Citation 2, item 2
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0May 11, 1994Closed

Inspection 122461064 OPENED MAY 4, 1994Closed

Monitoring · Partial · Health · 250 employees at the site · Closed May 16, 1994

N2480 County Hwy M, Browntown, WI 53522 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105942478 OPENED SEP 21, 1993Closed

Monitoring · Partial · Health · 219 employees at the site · Closed Oct 16, 1995

N2480 County Hwy M, Browntown, WI 53522 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$2,800$1,000Oct 12, 1993Final
Citation 1, item 2
29 CFR 1910.134(a)(1) · Respiratory protection
Serious$2,800$1,000Oct 12, 1993Final
Citation 1, item 3a
29 CFR 1910.179(m)(3)(x) · Overhead and gantry cranes
Serious$4,000$1,500Oct 12, 1993Final
Citation 1, item 3b Serious$0$0Oct 12, 1993Final
Citation 1, item 4a
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$4,000$1,500Nov 3, 1993Final
Citation 1, item 4b
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$0$0Nov 3, 1993Final
Citation 1, item 4c
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Nov 3, 1993Final
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Oct 12, 1993Closed

Inspection 102506748 OPENED NOV 14, 1991Closed

Planned · Complete · Health · 215 employees at the site · Closed Jan 5, 1998

N2480 County Hwy M, Browntown, WI 53522 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.23(a)(3) · Guarding floor and wall openings and holes
Serious$1,925$370Dec 19, 1991Final
Citation 1, item 1b
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$0$0Dec 19, 1991Final
Citation 1, item 2a
29 CFR 1910.37(f)(6) · Exit routes
Serious$925$550Dec 19, 1991Final
Citation 1, item 2b
29 CFR 1910.37(k)(2) · Exit routes
Serious$0$0Dec 19, 1991Final
Citation 1, item 2c
29 CFR 1910.37(q)(1) · Exit routes
Serious$0$0Dec 19, 1991Final
Citation 1, item 2d
29 CFR 1910.37(q)(2) · Exit routes
Serious$0$0Dec 19, 1991Final
Citation 1, item 2e
29 CFR 1910.37(q)(3) · Exit routes
Serious$0$0Dec 19, 1991Final
Citation 1, item 3a
29 CFR 1910.120(q)(6)(ie) · Hazardous waste operations and emergency response
Serious$1,100$440Dec 19, 1991Final
Citation 1, item 3b
29 CFR 1910.120(q)(6)(iid) · Hazardous waste operations and emergency response
Serious$0$0Dec 19, 1991Final
Citation 1, item 3c
29 CFR 1910.120(q)(6)(iiif) · Hazardous waste operations and emergency response
Serious$0$0Dec 19, 1991Final
Citation 1, item 3d
29 CFR 1910.120(q)(6)(ve) · Hazardous waste operations and emergency response
Serious$0$0Dec 19, 1991Final
Citation 1, item 3e
29 CFR 1910.1048(j) · Formaldehyde
Serious$0$0Dec 19, 1991Final
Citation 1, item 3f
29 CFR 1910.1048(j)(1) · Formaldehyde
Serious$0$0Dec 19, 1991Final
Citation 1, item 3g
29 CFR 1910.1048(j)(3) · Formaldehyde
Serious$0$0Dec 19, 1991Final
Citation 1, item 4
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$825$330Dec 19, 1991Final
Citation 1, item 5a
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,100$440Dec 19, 1991Final
Citation 1, item 5b
29 CFR 1910.1048(i)(2) · Formaldehyde
Serious$0$0Dec 19, 1991Final
Citation 1, item 5c
29 CFR 1910.1048(i)(3) · Formaldehyde
Serious$0$0Dec 19, 1991Final
Citation 1, item 6
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$1,100$440Dec 19, 1991Final
Citation 1, item 7
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,375$550Dec 19, 1991Final
Citation 1, item 8a
29 CFR 1910.212(a)(5) · Machine guarding
Serious$825$330Dec 19, 1991Final
Citation 1, item 8b
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$0$0Dec 19, 1991Final
Citation 1, item 9a
29 CFR 1910.213(h)(3) · Woodworking machinery
Serious$825$330Dec 19, 1991Final
Citation 1, item 9b
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Dec 19, 1991Final
Citation 1, item 10
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$825$330Dec 19, 1991Final
Citation 1, item 11
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$825$330Dec 19, 1991Final
Citation 1, item 12a
29 CFR 1910.305(a)(2)(iiib) · Electrical wiring methods
Serious$375$550Dec 19, 1991Final
Citation 1, item 12b
29 CFR 1910.305(a)(2)(iiig) · Electrical wiring methods
Serious$0$0Dec 19, 1991Final
Citation 1, item 12c
29 CFR 1910.305(j)(1)(ii) · Electrical wiring methods
Serious$0$0Dec 19, 1991Final
Citation 1, item 13a
29 CFR 1910.120(q)(2) · Hazardous waste operations and emergency response
Serious$1,100$440Dec 30, 1991Final
Citation 1, item 13b
29 CFR 1910.1048(k) · Formaldehyde
Serious$0$0Dec 30, 1991Final
Citation 2, item 1 Other-than-serious$0$0Dec 19, 1991Final
Citation 2, item 2
29 CFR 1910.147(f)(3)(iid) · Lockout/tagout
Other-than-serious$0$0Dec 19, 1991Final
Citation 2, item 3
29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Dec 19, 1991Final
Citation 2, item 4
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$550$220Dec 19, 1991Final
Citation 2, item 5
29 CFR 1910.254(d)(7) · Arc welding and cutting
Other-than-serious$0$0Dec 19, 1991Final
Citation 3, item 1 Serious$1,925$770Feb 5, 1992Final
Citation 3, item 2
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$825$330Feb 5, 1992Final
Citation 3, item 3a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$1,100$440Feb 5, 1992Final
Citation 3, item 3b
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$0$0Feb 5, 1992Final
Citation 3, item 3c
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Feb 5, 1992Final
Citation 3, item 4a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$1,100$440Feb 5, 1992Final
Citation 3, item 4b
29 CFR 1910.134(b)(1) · Respiratory protection
Serious$0$0Feb 5, 1992Final
Citation 3, item 5a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$825$330Feb 5, 1992Final
Citation 3, item 5b
29 CFR 1910.22(a)(1) · General requirements
Serious$0$0Feb 5, 1992Final
Citation 3, item 5c
29 CFR 1910.134(b)(11) · Respiratory protection
Serious$0$0Feb 5, 1992Final
Citation 3, item 6a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$2,750$1,100Feb 5, 1992Final
Citation 3, item 6b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Feb 5, 1992Final
Citation 3, item 6c
29 CFR 1910.134(b)(3) · Respiratory protection
Serious$0$0Feb 5, 1992Final
Citation 3, item 6d
29 CFR 1910.134(b)(5) · Respiratory protection
Serious$0$0Feb 5, 1992Final
Citation 3, item 6e
29 CFR 1910.134(b)(6) · Respiratory protection
Serious$0$0Feb 5, 1992Final
Citation 3, item 6f
29 CFR 1910.134(b)(11) · Respiratory protection
Serious$0$0Feb 5, 1992Final
Citation 4, item 1
29 CFR 1910.134(b)(6) · Respiratory protection
Other-than-serious$0$0Feb 5, 1992Final

Inspection 101377869 OPENED JUL 26, 1988Closed

Planned · Complete · Safety · 250 employees at the site · Closed Jul 26, 1989

N2480 County Hwy M, Browntown, WI 53522 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$420$200Aug 16, 1988Closed
Citation 1, item 2a
29 CFR 1910.242(a) · Hand and power tools
Serious$240$130Aug 16, 1988Closed
Citation 1, item 2b
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$0$0Aug 16, 1988Closed
Citation 2, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Repeat$60$40Aug 16, 1988Closed
Citation 2, item 2
29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts
Repeat$240$130Aug 16, 1988Closed
Citation 3, item 1
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Other-than-serious$0$0Aug 16, 1988Closed
Citation 3, item 2
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Other-than-serious$0$0Aug 16, 1988Closed
Citation 3, item 3
29 CFR 1910.106(e)(2)(iib)(2) · Flammable liquids
Other-than-serious$0$0Aug 16, 1988Closed
Citation 3, item 4
29 CFR 1910.108(c)(5) · [Reserved]
Other-than-serious$180$100Aug 16, 1988Closed
Citation 3, item 5 Other-than-serious$0$0Aug 16, 1988Closed
Citation 3, item 6
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Aug 16, 1988Closed
Citation 3, item 7
29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 16, 1988Closed
Citation 3, item 8
29 CFR 1910.1200(f)(8) · Hazard communication
Other-than-serious$0$0Aug 16, 1988Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2021, the Browntown site logged 2 recordable injuries or illnesses among about 123 workers: 1.7 per 100 full-time workers, against a median of 5.4 for its industry. Those cases cost 12 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Grede Wisconsin Subsidiaries LLC
Browntown · 2021
123 221.75.4

Included with any plan: 1 more yearly log from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 4 reports on file.

Jul 25, 2023, Browntown: Amputation · amputations · finger(s), fingernail(s), unspecified

An employee was loading castings onto a pallet. They were adjusting a casting by hand when their left ring finger was caught between the casting and the pallet. The finger was partially amputated and was later reattached.

Jul 19, 2018, Browntown: Hospitalization · heat (thermal) burns, unspecified · head and neck

A employee was attempting to chisel through a tuyere on a cupola melt deck that had started to solidify. When he created a hole through the chilled iron, molten iron exploded out of the tuyere and struck him on the right side of his face and neck. As he moved out of the way, he tripped over a water pipe on the deck; he fell, striking his head on the metal deck and losing consciousness.

Aug 30, 2017, Browntown: Hospitalization · heat (thermal) burns, unspecified · foot(feet) and leg(s), unspecified

An employee was using a skimming bar to remove slag from the top of a ladle of molten iron when the molten iron (2,600 degrees) poured down and burned his left leg and foot.

Aug 31, 2015, Reedsburg: Hospitalization · heat (thermal) burns, unspecified · hand(s), unspecified

At approximately 2:00 PM on 8/31/15, an employee was trying to retrieve the tip of a plunger that fell into a molten metal receiver. As he reached to retrieve the plunger, molten metal contacted and burned his left hand, requiring hospitalization.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(a)(2)

(2) Other substances—8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a “C”, shall not exceed the 8-hour Time Weighted Average given for that substance in any 8-hour work shift of a 40-hour work week.

29 CFR 1910.1000(c)

(c) Table Z-3. An employee's exposure to any substance listed in Table Z-3, in any 8-hour work shift of a 40-hour work week, shall not exceed the 8-hour time weighted average limit given for that substance in the table.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.1001 · Asbestos in general industry

29 CFR 1910.1020 · Access to employee exposure and medical records

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1028 · Benzene

29 CFR 1910.1048 · Formaldehyde

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.108 · [Reserved]

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.20

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.26 · Portable metal ladders

29 CFR 1910.27 · Fixed ladders

29 CFR 1910.28 · Safety requirements for scaffolding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.332 · Training

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.94 · Ventilation

29 CFR 1910.95 · Noise

OSH Act Section 5 · General Duty Clause

Other iron foundries employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.