OSHA SearchOSHA records by employer

Martin Steel Inc.: OSHA inspections and violations

Huntington, West Virginia · Fabricated Structural Metal Manufacturing · NAICS 332312

18inspections
138citation items
$53,691current penalties
Apr 20, 2023last inspection

OSHA has inspected Martin Steel Inc. 18 times in West Virginia since 1973.

The latest one began on Apr 20, 2023 as a planned inspection, in Huntington.

Those inspections ended with 138 citation items: 74 serious, 2 repeat and 62 other-than-serious.

Penalties were first proposed at $85,887 and now stand at $53,691, 37% lower after settlements or reviews.

Flammable liquids comes up most often in these citations: 17 items under 1910.106.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Martin Steel Inc. averages $3,357 (3 cited inspections).

Martin Steel Inc. also files yearly injury logs with OSHA, summarized below.

Martin Steel Inc.: OSHA citation items per year, 1973 to 2023
Citation items per year, by inspection date.

West Virginia · latest 90 days of OSHA records

27employers cited

Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in West Virginia

Checking a subcontractor, a client or your own company? Watch Martin Steel Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346648157 OPENED APR 20, 2023Closed

Planned · Partial · Safety · 14 employees at the site · Closed Sep 7, 2023

603 West 16th Street, Huntington, WV 25704 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344640479 OPENED FEB 20, 2020Closed

Follow-up · Partial · Health · 27 employees at the site · Closed Feb 1, 2021

603 Sixteenth Street West, Huntington, WV 25704 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1903.16(a) · Posting of citations
Other-than-serious$4,048$2,834Aug 19, 2020Final

Inspection 344280938 OPENED SEP 4, 2019Closed

Planned · Partial · Health · 27 employees at the site · Closed Aug 6, 2020

603 West 16th Street, Huntington, WV 25704 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$3,978$3,978Oct 18, 2019Final
Citation 1, item 1b Serious$0$0Oct 18, 2019Final
Citation 1, item 1c Serious$0$0Oct 18, 2019Final

Inspection 342151396 OPENED MAR 3, 2017Closed

Planned · Partial · Safety · 20 employees at the site · Closed Mar 30, 2017

603 West 16th Street, Huntington, WV 25704 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,346$3,260Mar 9, 2017Final

Inspection 339092447 OPENED MAY 30, 2013Closed

Planned · Partial · Safety · 32 employees at the site · Closed Dec 18, 2013

603 16th Street West, Huntington, WV 25704 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Repeat$4,200$2,940Sep 24, 2013Final
Citation 1, item 2
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Repeat$7,000$4,900Sep 24, 2013Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,800$1,960Sep 24, 2013Final
Citation 1, item 4
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,500$2,450Sep 24, 2013Final
Citation 2, item 1
29 CFR 1910.134(k)(5)(ii) · Respiratory protection
Other-than-serious$0$0Sep 24, 2013Final

Inspection 313372633 OPENED MAR 19, 2010Closed

Planned · Complete · Safety · 25 employees at the site · Closed Jul 21, 2010

603 16th West, Huntington, WV 25704 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$750$600Jun 30, 2010Closed
Citation 1, item 1b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Jun 30, 2010Closed
Citation 1, item 1c
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Jun 30, 2010Closed
Citation 1, item 1d
29 CFR 1910.134(k)(3) · Respiratory protection
Serious$0$0Jun 30, 2010Closed
Citation 1, item 1e
29 CFR 1910.134(k)(6) · Respiratory protection
Serious$0$0Jun 30, 2010Closed
Citation 1, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$750$600Jun 30, 2010Closed
Citation 1, item 4
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$750$600Jun 30, 2010Closed
Citation 1, item 5a
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$2,100$1,680Jun 30, 2010Closed
Citation 1, item 5b
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Serious$0$0Jun 30, 2010Closed
Citation 1, item 6a
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$750$600Jun 30, 2010Closed
Citation 1, item 6b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Jun 30, 2010Closed
Citation 1, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$600$480Jun 30, 2010Closed

Inspection 116499518 OPENED FEB 13, 2003Closed

Planned · Partial · Safety · 40 employees at the site · Closed Mar 19, 2003

603 16th West, Huntington, WV 25704 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.4(a) · Recording criteria
Other-than-serious$0$0Mar 4, 2003Closed
Citation 1, item 2
29 CFR 1904.32(a)(4) · Yearly injury summary
Other-than-serious$0$0Mar 4, 2003Closed

Inspection 116494014 OPENED JAN 19, 2000Closed

Complaint · Partial · Health · 43 employees at the site · Closed Mar 31, 2000

603 16th West, Huntington, WV 25704 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$875$600Jan 28, 2000Closed
Citation 1, item 1b Serious$0$0Jan 28, 2000Closed
Citation 1, item 2a Serious$875$600Jan 28, 2000Closed
Citation 1, item 2b Serious$0$0Jan 28, 2000Closed
Citation 1, item 3
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$525$300Jan 28, 2000Closed
10 older inspections

Inspection 116241050 OPENED JUN 14, 1995Closed

Complaint · Partial · Safety · 46 employees at the site · Closed Aug 15, 1995

603 16th West, Huntington, WV 25704 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$500$500Jul 31, 1995Closed
Citation 1, item 2a
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$250$250Jul 31, 1995Closed
Citation 1, item 2b
29 CFR 1910.253(e)(1) · Gas welding and cutting
Serious$0$0Jul 31, 1995Closed
Citation 2, item 1
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Other-than-serious$0$0Jul 31, 1995Closed

Inspection 100593623 OPENED MAR 18, 1992Closed

Follow-up · Partial · Safety · 10 employees at the site · Closed Apr 24, 1992

603 16th West, Huntington, WV 25704 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 100784420 OPENED MAY 9, 1991Closed

Complaint · Complete · Safety · 40 employees at the site · Closed Jul 24, 1992

603 - 16th Street West, Huntington, WV 25704 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Serious$2,100$709Jun 21, 1991Closed
Citation 1, item 2
29 CFR 1910.22(a)(2) · General requirements
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 3
29 CFR 1910.25(d)(1)(x) · Portable wood ladders
Serious$2,100$709Jun 21, 1991Closed
Citation 1, item 4
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 5
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 6a
29 CFR 1910.106(d)(1) · Flammable liquids
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 6b
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$0$0Jun 21, 1991Closed
Citation 1, item 6c
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$0$0Jun 21, 1991Closed
Citation 1, item 7
29 CFR 1910.106(d)(4)(iii) · Flammable liquids
Serious$1,500$709Jun 21, 1991Closed
Citation 1, item 8
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$900$709Jun 21, 1991Closed
Citation 1, item 9
29 CFR 1910.106(d)(4)(v) · Flammable liquids
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 10
29 CFR 1910.106(d)(7)(ia) · Flammable liquids
Serious$1,500$709Jun 21, 1991Closed
Citation 1, item 11
29 CFR 1910.106(e)(2)(iib) · Flammable liquids
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 12
29 CFR 1910.106(d)(4)(v) · Flammable liquids
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 13
29 CFR 1910.106(e)(2)(iva) · Flammable liquids
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 14
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$3,000$730Jun 21, 1991Closed
Citation 1, item 15
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,500$709Jun 21, 1991Closed
Citation 1, item 16
29 CFR 1910.176(a) · Material storage and aisles
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 17a
29 CFR 1910.179(g)(1)(iv) · Overhead and gantry cranes
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 17b
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Serious$0$0Jun 21, 1991Closed
Citation 1, item 18a Serious$3,000$709Jun 21, 1991Closed
Citation 1, item 18b Serious$0$0Jun 21, 1991Closed
Citation 1, item 18c Serious$0$0Jun 21, 1991Closed
Citation 1, item 19a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 19b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Jun 21, 1991Closed
Citation 1, item 20
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$2,100$709Jun 21, 1991Closed
Citation 1, item 21
29 CFR 1910.253(a)(3) · Gas welding and cutting
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 22a
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 22b
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$0$0Jun 21, 1991Closed
Citation 1, item 23
29 CFR 1910.254(d)(8) · Arc welding and cutting
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 24
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Serious$2,100$709Jun 21, 1991Closed
Citation 1, item 25
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$1,200$709Jun 21, 1991Closed
Citation 1, item 26
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Serious$2,100$709Jun 21, 1991Closed
Citation 1, item 27
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$900$709Jun 21, 1991Closed
Citation 1, item 28
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$900$709Jun 21, 1991Closed
Citation 1, item 29a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$900$709Jun 21, 1991Closed
Citation 1, item 29b
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$0$0Jun 21, 1991Closed
Citation 1, item 30
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$900$709Jun 21, 1991Closed
Citation 1, item 31
29 CFR 1910.1200(h) · Hazard communication
Serious$900$709Jun 21, 1991Closed
Citation 2, item 1
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jun 21, 1991Closed
Citation 2, item 2
29 CFR 1910.23(e)(5)(iv) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jun 21, 1991Closed
Citation 2, item 3 Other-than-serious$0$0Jun 21, 1991Closed
Citation 2, item 4
29 CFR 1910.106(b)(6) · Flammable liquids
Other-than-serious$0$0Jun 21, 1991Closed
Citation 2, item 5 Other-than-serious$0$0Jun 21, 1991Closed
Citation 2, item 6
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jun 21, 1991Closed
Citation 2, item 7
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Other-than-serious$0$0Jun 21, 1991Closed
Citation 2, item 8
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 21, 1991Closed

Inspection 760868 OPENED MAR 8, 1988Closed

Planned · Complete · Safety · 20 employees at the site · Closed Oct 3, 1988

603 - 16th Street West, Huntington, WV 25704 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$300$150Mar 15, 1988Closed
Citation 1, item 2
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$360$180Mar 15, 1988Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$60$60Mar 15, 1988Closed
Citation 2, item 2 Other-than-serious$0$0Mar 15, 1988Closed
Citation 2, item 3 Other-than-serious$0$0Mar 15, 1988Closed
Citation 2, item 4 Other-than-serious$0$0Mar 15, 1988Closed
Citation 2, item 5
29 CFR 1910.134(d)(2)(ii) · Respiratory protection
Other-than-serious$0$0Mar 15, 1988Closed
Citation 2, item 6 Other-than-serious$0$0Mar 15, 1988Closed
Citation 2, item 7 Other-than-serious$0$0Mar 15, 1988Closed
Citation 2, item 8
29 CFR 1910.179(g)(1)(iv) · Overhead and gantry cranes
Other-than-serious$0$0Mar 15, 1988Closed
Citation 2, item 9
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Other-than-serious$0$0Mar 15, 1988Closed
Citation 2, item 10
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 15, 1988Closed
Citation 2, item 11
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 15, 1988Closed
Citation 2, item 12
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Mar 15, 1988Closed
Citation 2, item 13
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Mar 15, 1988Closed

Inspection 824565 OPENED MAR 12, 1985Closed

Planned · Records only · Safety · 33 employees at the site · Closed Mar 20, 1985

603 16th St West, Huntington, WV 25704 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 12354429 OPENED AUG 23, 1983Closed

Planned · Complete · Health · 9 employees at the site · Closed Feb 8, 1984

603 16th St West, Huntington, WV 25704 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 12319760 OPENED APR 12, 1982Closed

Planned · Complete · Safety · 43 employees at the site · Closed May 17, 1982

603 West 16th Street, Huntington, WV 25704 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(m)(1) · Overhead and gantry cranes
Serious$280$280Apr 27, 1982Closed
Citation 1, item 2
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$420$420Apr 27, 1982Closed
Citation 2, item 1
29 CFR 1910.242(a) · Hand and power tools
Other-than-serious$0$0Apr 27, 1982Closed

Inspection 12352753 OPENED FEB 25, 1981Closed

Planned · Complete · Health · 24 employees at the site · Closed Feb 17, 1983

603 W 16th Street, Huntington, WV 25704 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$200$200May 5, 1981Closed
Citation 1, item 2
29 CFR 1910.107(c)(9) · Spray painting and finishing
Serious$240$240May 5, 1981Closed
Citation 1, item 3
29 CFR 1910.110(c)(5)(ig) · Storage and handling of liquefied petroleum gases
Serious$200$200May 5, 1981Closed
Citation 1, item 4
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Serious$160$160May 5, 1981Closed
Citation 1, item 5
29 CFR 1910.242(b) · Hand and power tools
Serious$160$160May 5, 1981Closed
Citation 2, item 1
29 CFR 1910.106(e)(7)(ic) · Flammable liquids
Other-than-serious$0$0May 5, 1981Closed
Citation 2, item 2
29 CFR 1910.1025(d)(2) · Lead in general industry
Other-than-serious$0$0May 5, 1981Closed

Inspection 12317202 OPENED MAR 31, 1976Closed

Planned · Complete · Safety · 43 employees at the site · Closed Jun 22, 1976

603 West Sixteenth Street, Huntington, WV 25708 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(2) · General requirements
Other-than-serious$40$40Apr 8, 1976Closed
Citation 1, item 2
29 CFR 1910.24(b) · Fixed industrial stairs
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 3
29 CFR 1910.28(a)(1) · Safety requirements for scaffolding
Other-than-serious$45$45Apr 19, 1976Closed
Citation 1, item 4
29 CFR 1910.106(d)(5)(v) · Flammable liquids
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 5
29 CFR 1910.106(e)(2)(ii) · Flammable liquids
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 6
29 CFR 1910.106(e)(2)(ivd) · Flammable liquids
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 7
29 CFR 1910.107(c)(2) · Spray painting and finishing
Other-than-serious$45$45Apr 8, 1976Closed
Citation 1, item 8
29 CFR 1910.107(c)(6) · Spray painting and finishing
Other-than-serious$45$45Apr 8, 1976Closed
Citation 1, item 9
29 CFR 1910.107(e)(5) · Spray painting and finishing
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 10
29 CFR 1910.107(e)(9) · Spray painting and finishing
Other-than-serious$45$45Apr 8, 1976Closed
Citation 1, item 11
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 12
29 CFR 1910.110(f)(2)(ii) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 13
29 CFR 1910.110(f)(4)(i) · Storage and handling of liquefied petroleum gases
Other-than-serious$45$45Apr 8, 1976Closed
Citation 1, item 14 Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 15
29 CFR 1910.157(a)(2) · Portable fire extinguishers
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 16
29 CFR 1910.157(c)(1)(ii) · Portable fire extinguishers
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 17
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 18
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 19
29 CFR 1910.179(m)(1) · Overhead and gantry cranes
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 20
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 21
29 CFR 1910.217(b)(1) · Mechanical power presses
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 22
29 CFR 1910.217(b)(4)(i) · Mechanical power presses
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 23
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Other-than-serious$65$65Apr 19, 1976Closed
Citation 1, item 24
29 CFR 1910.217(e)(1)(ii) · Mechanical power presses
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 25
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Other-than-serious$55$55Apr 8, 1976Closed
Citation 1, item 26
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Other-than-serious$45$45Apr 8, 1976Closed
Citation 1, item 27
29 CFR 1910.252(e)(1)(ii) · Welding fire safety
Other-than-serious$0$0Apr 8, 1976Closed
Citation 1, item 28
29 CFR 1910.252(e)(2)(iii) · Welding fire safety
Other-than-serious$55$55Apr 8, 1976Closed
Citation 1, item 29 Other-than-serious$0$0Apr 8, 1976Closed

Inspection 12281838 OPENED NOV 19, 1973Closed

Planned · Complete · Safety · 32 employees at the site · Closed Mar 10, 1984

603 16 Th Street West, Huntington, WV 25708 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$25$25Dec 13, 1973Closed
Citation 1, item 2
29 CFR 1910.22(a)(2) · General requirements
Other-than-serious$0$0Dec 13, 1973Closed
Citation 1, item 3
29 CFR 1910.22(b)(2) · General requirements
Other-than-serious$0$0Dec 13, 1973Closed
Citation 1, item 4
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Dec 13, 1973Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Huntington site logged 0 recordable injuries or illnesses among about 20 workers: 0.0 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Martin Steel, Inc.
Huntington · 2017
20 000.03.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.16 · Posting of citations

29 CFR 1903.16(a)

(a) Upon receipt of any citation under the Act, the employer shall immediately post such citation, or a copy thereof, unedited, at or near each place an alleged violation referred to in the citation occurred, except as provided below. Where, because of the nature of the employer's operations, it is not practicable to post the citation at or near each place of alleged violation, such citation shall be posted, unedited, in a prominent place where it will be readily observable by all affected employees. For example, where employers are engaged in activities which are physically dispersed (see § 1903.2(b)), the citation may be posted at the location to which employees report each day. Where employees do not primarily work at or report to a single location (see § 1903.2(b)), the citation may be posted at the location from which the employees operate to carry out their activities. The employer

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1904.32 · Yearly injury summary

29 CFR 1904.32(a)(4)

(4) Post the annual summary.

29 CFR 1904.4 · Recording criteria

29 CFR 1904.4(a)

(a) Basic requirement. Each employer required by this part to keep records of fatalities, injuries, and illnesses must record each fatality, injury and illness that:

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.28 · Safety requirements for scaffolding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.309

29 CFR 1910.94 · Ventilation

29 CFR 1910.95 · Noise

OSH Act Section 5 · General Duty Clause

Other fabricated structural metal manufacturing employers in West Virginia

Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.