OSHA SearchOSHA records by employer

Oncor Electric Delivery, LLC: OSHA inspections and violations

Fort Worth, Texas · Electric Power Distribution · NAICS 221122

12inspections
11citation items
$132,288current penalties
Apr 21, 2026last inspection

Since 2007, OSHA inspectors have visited Oncor Electric Delivery, LLC in Texas 12 times.

The most recent inspection opened on Apr 21, 2026 as part of a related case, in Fort Worth.

In all, OSHA issued 11 citation items: 5 serious and 6 other-than-serious.

The proposed penalties came to $210,551; today they stand at $132,288, 37% less.

The rule cited most here is 1910.269 (electric power generation, transmission, and distribution), 3 times.

Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Oncor Electric Delivery, LLC averages $31,110 across 4 cited inspections.

2 inspections on this page followed a fatal incident.

Oncor Electric Delivery, LLC also files yearly injury logs with OSHA, summarized below.

It reported 6 severe injuries to OSHA since 2015.

The Wage and Hour Division has 1 case on it since 2015, with $0 in back wages owed to workers.

Oncor Electric Delivery, LLC: OSHA citation items per year, 2007 to 2026
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Oncor Electric Delivery, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348881491 OPENED APR 21, 2026Closed

Unprogrammed related · Partial · Safety · 5,300 employees at the site · Closed Oct 8, 2026

5800 East Berry, Fort Worth, TX 76119 · All Other Miscellaneous Electrical Equipment and Component Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348613977 OPENED NOV 24, 2025Open

Fatality or catastrophe · Partial · Safety · 1 employee at the site · Open

4701 Kelley Drive, Georgetown, TX 78626 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$16,550$16,550May 22, 2026Final
Citation 1, item 2
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$16,550$16,550May 22, 2026Final
Citation 1, item 3
29 CFR 1926.21(b)(2) · Construction safety training
Serious$16,550$16,550May 22, 2026Final

Inspection 348148354 OPENED APR 3, 2025Closed

Referral · Partial · Safety · 5 employees at the site · Closed Sep 8, 2025

3300 Sherman Ave., Fort Worth, TX 76106 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Other-than-serious$16,550$16,550Jul 25, 2025Final

Inspection 346415995 OPENED JAN 4, 2023Closed

Referral · Partial · Safety · 4,600 employees at the site · Closed May 10, 2024

1701 N Market Street, Dallas, TX 75202 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.9(b) · Compliance duties owed to each employee
Other-than-serious$15,625$15,625May 23, 2023Final
Citation 2, item 1
29 CFR 1910.269(t)(7)(ii) · Electric power generation, transmission, and distribution
Other-than-serious$85,938$15,625May 23, 2023Final

Inspection 344497367 OPENED DEC 3, 2019Closed

Programmed related · Partial · Safety · 4,000 employees at the site · Closed Feb 19, 2020

Texas & Monroe St., Fort Worth, TX 76108 · All Other Miscellaneous Electrical Equipment and Component Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344463310 OPENED NOV 21, 2019Closed

Fatality or catastrophe · Partial · Safety · 4,000 employees at the site · Closed Jun 4, 2020

Cr 1536 3-miles S Of Chico; Near Intersection Tx 101, Chico, TX 76431 · All Other Miscellaneous Electrical Equipment and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Nov 20, 2019 (fatal): One employee is killed, another is injured by electrical lin

At 3:00 p.m. on November 20, 2019, Employee #1 and a Employee #2 were setting a wood pole in a distribution line. It is believed that a gust of wind caught or drifted the pole and caused the pole to hit the electrical transmission lines. The employees were holding the pole with their hands. Employee #1 was electrocuted when the pole touched the high voltage line and Employee #2 was also injured and taken to the hospital.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.952(b) · Job briefing
Serious$13,494$13,494Apr 15, 2020Final
Citation 1, item 3
OSH Act Section 5(a)(1) · General Duty Clause
Serious$13,494$13,494Apr 15, 2020Final

Inspection 343176087 OPENED MAY 10, 2018Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed May 10, 2018

Nail Ranch A-6 Swd, Midland, TX 79701 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342743580 OPENED OCT 31, 2017Closed

Referral · Partial · Health · 10 employees at the site · Closed Dec 15, 2017

928 Martin Luther King Dr., Nacogdoches, TX 75961 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Incident on Oct 29, 2017: Employee tests transformer with under-rated equipment and su

At 9:45 a.m. on October 29, 2017, an employee was checking the voltage after restoring power to a customer and used a volt meter rated for 1,000 volts on a transformer with 4,160 volts, creating an arc flash. The employee suffered second degree burns to both hands and was hospitalized.

No citations from this inspection.

4 older inspections

Inspection 336914189 OPENED OCT 16, 2012Closed

Referral · Partial · Safety · 3,800 employees at the site · Closed Sep 23, 2013

1700 West Cannon Street, Fort Worth, TX 76104 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.269(m)(3)(v) · Electric power generation, transmission, and distribution
Other-than-serious$7,000$3,500Feb 28, 2013Final

Inspection 314178617 OPENED SEP 4, 2010Closed

Referral · Complete · Safety · 3,800 employees at the site · Closed Oct 4, 2012

1909 Jamestown Lane, Carrollton, TX 75006 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3
29 CFR 1910.269(j)(2)(iii) · Electric power generation, transmission, and distribution
Other-than-serious$2,500$1,250Mar 2, 2011Final

Inspection 314176173 OPENED MAY 3, 2010Closed

Accident · Complete · Safety · 3,800 employees at the site · Closed May 1, 2012

7777 Forest Lane, Dallas, TX 75230 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Incident on May 2, 2010: Three employees get burns and injured due to arc flash

On May 2, 2010, Employee #1 and Employee #2 of Medical City Dallas Hospital and Employee #1 of Oncor Electric Delivery, were burned due to an arc flash and fire while Employee #1 of Oncor Electric Delivery was opening a phase potential swit ch from ESCO Load Break Switch of 13,200 volts phase to phase to perform the tra nsfer switch. All Employees were hospitalized and treated for their burns and sc alds due to the flash.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.137(b)(2)(ii) · Electrical protective equipment
Other-than-serious$6,300$3,100Nov 1, 2010Final

Inspection 310442447 OPENED SEP 25, 2007Closed

Accident · Partial · Safety · 3,394 employees at the site · Closed Nov 14, 2007

6019 Guilford, Forest Hill, TX 76119 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

Incident on Sep 22, 2007 (fatal): Employee is electrocuted

On September 22, 2007, Employee #1 was a Troubleshooter. He had responded to a r equest for service for lights out. He was found slumped over in the bucket by a coworker. He had been electrocuted, but the means or manner was not specified in the narrative.

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Fort Worth site logged 0 recordable injuries or illnesses among about 1,216 workers: 0.0 per 100 full-time workers, against a median of 1.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
777 Main
Fort Worth · 2025
1,216 000.01.0
Woodall
Dallas · 2025
832 110.11.0
West DOC
Fort Worth · 2025
187 100.41.0
Dallas (SW)
Dallas · 2025
114 100.81.0
Dallas (TGM)
Dallas · 2025
125 000.01.0
FT Worth North SVC CTR
Fort Worth · 2025
88 404.11.0
Midland SVC CTR
Midland · 2025
99 202.11.0
Ft Worth Transmission
Fort Worth · 2025
94 313.51.0

Included with any plan: 123 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 6 reports on file.

Mar 22, 2025, Fort Worth: Hospitalization · fractures · back lumbar region

On March 22, 2025, an employee fell from a de-energized substation transformer to the ground while disassembling the substation. The employee was hospitalized with a fracture to their L2 vertebra. Fall protection was in place at the time.

Dec 29, 2022, Dallas: Hospitalization · second degree electrical burns · multiple head locations

An employee was working inside of a network vault to repair a conductor. The conductor became energized and a metal wire came in contact with the conductor, causing an arc flash. The employee sustained second-degree burns to the face and head.

Sep 1, 2021, Dallas: Hospitalization · effects of heat and light, n.e.c. · body systems

An employee had been setting up before entering a manhole. He became overheated and was later hospitalized with dehydration.

Jul 28, 2021, Dallas: Hospitalization · third or fourth degree electrical burns · hand(s), unspecified

An employee was assisting with the manual handling and positioning of a de-energized jacketed concentric neutral power cable in an electrical vault. A 15 kV component installed on a transformer failed, resulting in an arc flash that caused second and third degree burns on the employee's hands.

Feb 20, 2021, Dallas: Hospitalization · soreness, pain, hurt-nonspecified injury · multiple body parts, n.e.c.

An employee was in the back of a truck, trying to get a transformer un-wedged from underneath an object. His hand slipped and he fell off the back of the truck, landing on his back. He was hospitalized, suffering from lower back pain and pain down his right leg.

Oct 29, 2017, Nacogdoches: Hospitalization · second degree electrical burns · hand(s), unspecified

An employee was checking voltage after restoring electrical power to a customer when an arc flash occurred causing second degree burns to the hands. The employee was admitted to the hospital.

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Nov 12, 2014 to May 12, 2015
Dallas
10$0$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.137 · Electrical protective equipment

29 CFR 1910.137(b)(2)(ii)

(ii) When insulating equipment is tested in accordance with paragraph (b)(2)(i) of this section, the equipment current may not exceed 1 microampere per kilovolt of phase-to-phase applied voltage.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.269(j)(2)(iii)

(iii) Live-line tools used for primary employee protection shall be removed from service every 2 years, and whenever required under paragraph (j)(2)(ii) of this section, for examination, cleaning, repair, and testing as follows:

29 CFR 1910.269(m)(3)(v)

(v) Tags shall prohibit operation of the disconnecting means and shall indicate that employees are at work.

29 CFR 1910.9 · Compliance duties owed to each employee

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.952 · Job briefing

OSH Act Section 5 · General Duty Clause

Other electric power distribution employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.