OSHA SearchOSHA records by employer

Tmi Electrical Contractors, Inc.: OSHA inspections and violations

Cincinnati, Ohio · Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing · NAICS 335122

4inspections
9citation items
$24,788current penalties
Feb 8, 2019last inspection

Tmi Electrical Contractors, Inc. has 4 OSHA inspections on record in Ohio, the first in 2002.

OSHA's last visit started on Feb 8, 2019 on a referral, in Cincinnati.

Across those inspections OSHA issued 9 citation items: 7 serious and 2 other-than-serious.

OSHA proposed $50,416 in penalties. After settlements and reviews the total is $24,788, down 51%.

Most often, OSHA cited 1926.1053, ladders in construction (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Tmi Electrical Contractors, Inc. averages $22,608 over 1 cited inspection in that time.

Tmi Electrical Contractors, Inc. also files yearly injury logs with OSHA, summarized below.

Tmi Electrical Contractors, Inc.: OSHA citation items per year, 2002 to 2019
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

265employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Tmi Electrical Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343772596 OPENED FEB 8, 2019Closed

Referral · Partial · Safety · 37 employees at the site · Closed May 24, 2019

4620 Wesley Ave, Cincinnati, OH 45212 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$7,293$3,646Apr 5, 2019Final
Citation 1, item 1b
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Apr 5, 2019Final
Citation 1, item 2
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$10,210$5,105Apr 5, 2019Final
Citation 1, item 3
29 CFR 1926.417(a) · Lockout and tagging of circuits
Serious$10,210$5,105Apr 5, 2019Final
Citation 1, item 4
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$10,210$5,105Apr 5, 2019Final
Citation 2, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$7,293$3,646Apr 5, 2019Final

Inspection 314099862 OPENED JAN 14, 2010Closed

Planned · Partial · Safety · 11 employees at the site · Closed Mar 12, 2010

7875 Montgomery Road, Cincinnati, OH 45236 · Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms
Serious$1,500$1,500Feb 9, 2010Closed

Inspection 305334658 OPENED APR 26, 2002Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jul 23, 2002

3301 Compton Rd., Cincinnati, OH 45251 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$1,200$480May 10, 2002Closed

Inspection 305164774 OPENED FEB 25, 2002Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Apr 4, 2002

7440 Mason Montgomery Rd, Mason, OH 45040 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Other-than-serious$2,500$200Mar 11, 2002Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Cincinnati site logged 0 recordable injuries or illnesses among about 27 workers: 0.0 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Tmi Electrical Contractors Inc
Cincinnati · 2022
27 000.01.8

Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms

29 CFR 1910.67(c)(2)(v)

(v) A personal fall arrest or travel restraint system that meets the requirements in subpart I of this part shall be worn and attached to the boom or basket when working from an aerial lift.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.417 · Lockout and tagging of circuits

Other commercial, industrial, and institutional electric lighting fixture manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.